Evaluate the precision and accuracy of the Proxima 3® System by obtaining quantitative clinical data at various time points. Compare the methods associated with obtaining blood gas results using the Proxima 3® System device versus a conventional ABG analyse. The aim of the investigator is to evaluate the precision and accuracy of the Proxima 3® ABG system parameters (pH, pCO2 pO2, hematocrit and potassium) in clinical practices with rapid changing context.
In this study the investigator will test the applicability of the Proxima 3® ABG system in a heterogeneous patient population consisting of patients scheduled for hybrid atrial fibrillation surgery, patients scheduled for heart valve surgery, complex cardiac surgery with deep cooling, spine surgery or patients with expected major blood loss. The investigator will compare the ABG values obtained with the traditional ABG measurement system of the hospital.
The availability of a disposable patient-dedicated blood gas analyser allows rapid, frequent measurement of blood gases in theatre without the loss of theatre staff. As well as facilitating measurement in the unstable patient, this approach opens up the possibility for more frequent measurement to identify patient deterioration before a crisis occurs.
The conventional laboratory ABG method uses sensor technology for pH, pCO2, pO2, sodium, potassium, calcium, glucose and lactate levels. It measures hemoglobin concentration via spectrophotometry methodology at a set wavelength of 467-672 nm. The blood gas laboratory uses ABL90 Flex (Radiometer®). The optical system is based on a 138-wavelength spectrophotometer with a measuring range of 467-672 nm. The spectrophotometer is connected via an optical fiber to a combined hemolyzer and measuring chamber.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Conventional ABG analyser | Active Comparator |
| |
| Proxima 3® arterial blood gas | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| conventional ABG analyser | Device | pO2 mmHg, pH, pCO2 mmHg, Base excess, Hct % |
|
| Measure | Description | Time Frame |
|---|---|---|
| Evaluation of accuracy and precision of the Proxima 3® for ABG | Evaluate the precision and accuracy of the Proxima 3® System by obtaining quantitative clinical data at various time points | From intubation until extubation, max 1 day |
| Measure | Description | Time Frame |
|---|---|---|
| Time to obtain an arterial blood gas | Time for obtaining arterial blood gas: prelevation time to result time | From intubation until extubation, max 1 day |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Vincent Umbrain, MD PhD | Universitair Ziekenhuis Brussel | Principal Investigator |
| Jan Poelaert, MD, PhD | Universitair Ziekenhuis Brussel | Study Director |
| Manuella Martin, Apr. Biol. | Universitair Ziekenhuis Brussel | Study Chair |
| Christine Sneyers, Nurse | Universitair Ziekenhuis Brussel | Principal Investigator |
| Gabriel Kotolácsi, MD | Universitair Ziekenhuis Brussel | Principal Investigator |
| Pierre Matagne, Nurse | Universitair Ziekenhuis Brussel | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Universitair Ziekenhuis Brussel | Jette | Vlaams-Brabant | 1090 | Belgium |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000860 | Hypoxia |
| D006935 | Hypercapnia |
| D000740 | Anemia |
| ID | Term |
|---|---|
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D006402 | Hematologic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Proxima 3® | Device | pO2 mmHg, pH, pCO2 mmHg, Base excess, Hct % |
|
| D006425 | Hemic and Lymphatic Diseases |