Self-apposing, drug-eluting Stentys coronary stents represent a valuable tool for the treatment of coronary artery stenosis. Their ability to adapt to widely varying vessel calibers and to auto-expand after their release to self-appose to vessel walls is particularly useful in the presence of ectasic coronary arteries or significant vessel tapering. The investigators planned this study to assess the feasibility, the effectiveness and the safety of the implantation of self-apposing, drug-eluting Stentys stents for percutaneous coronary intervention.
Consecutive patients undergoing percutaneous coronary intervention with implantation of a self-apposing Stentys stent were enrolled in this multi center registry. Inclusion criteria were age ≥ 18 years and ability to provide informed consent. No exclusion criteria were defined.
Primary end-point of the study is the occurrence of MACE (death, myocardial infarction, stent thrombosis, unplanned hospitalization for unstable angina, target lesion revascularization). Secondary end-points include individual components of MACE, procedural complications (periprocedural MI, bleedings, access site complication, failure to cross stent struts with guidewire in the treatment of bifurcation, failure to delivery the stent, contrast-induced nephropathy), bleedings at follow up.
Rationale: Choice of the appropriate size of stents in the treatment of coronary artery stenosis can often be challenging. Marked tapering of vessels' diameter in their proximal-distal development may lead to sub-optimal results. Distal under-expansion of the drug-eluting stent (DES) or vessel perforation may occur if a larger DES, best suited for the proximal diameter, is chosen. Proximal DES under-sizing with struts malapposition may happen if a smaller DES, fitting the distal diameter, is implanted. Moreover, ectasic vessels present irregular and varying diameter, which may lead as well to segmental malapposition or under-expansion of DES. Self-apposing stents can overcome these limitations thanks to their ability to self-expand also after their release in the vessel and to adapt to a wide range of vessel diameters. Multiple generation of self-apposing, drug-eluting stents have been developed, with progressive amendments pertaining the stent-deployment technique (from deployment by covering-sheath retraction to balloon-delivery) and the drug released (from paclitaxel to sirolimus). The last generation of the self-apposing stents is represented by the sirolimus-eluting, balloon-delivered Xposition S stents. Studies assessing performance of this stent are however limited in sample size and length of follow up, and are mainly controlled trials. Few data are available regarding the clinical outcomes of the self-apposing Stentys stents in a "real-life" setting.
Aim of this study is to assess the feasibility, the effectiveness and the safety of the implantation of self-apposing, drug-eluting Stentys stents for percutaneous coronary intervention.
Study population: Patients undergoing percutaneous coronary intervention with implantation of a self-apposing Stentys stent.
Primary analysis: Longitudinal cohort follow up
Study end-points:
Primary efficacy end-point:
Secondary efficacy end-points:
Secondary safety end-points:
Procedural complications:
Bleedings at follow up
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Major Adverse Cardiovascular Events (MACE) | A composite end-point of death, myocardial infarction, stent thrombosis, unplanned hospitalization for unstable angina, target lesion revascularization | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Death | 12 months | |
| Myocardial Infarction | Incident rate of myocardial infarction | 12 months |
| Stent thrombosis |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Consecutive patients undergoing percutaneous treatment of coronary artery disease with implantation of a self-apposing, drug-eluting, Stentys stent
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Sebastiano Gili, MD | Contact | +393338354923 | sebastiano.gili@gmail.com | |
| Antonio Montefusco, MD | Contact | anto.montefusco@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Claudio Moretti, MD | Division of Cardiology, Department of Medical Sciences, AO Città della Salute e della Scienza, University of Turin, Turin, Italy | Principal Investigator |
| Antonio Montefusco, MD | Division of Cardiology, Department of Medical Sciences, AO Città della Salute e della Scienza, University of Turin, Turin, Italy |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Division of Cardiology, Mazzoni Hospital | Recruiting | Ascoli Piceno | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25983027 | Background | Lu H, IJsselmuiden AJ, Grundeken MJ, Nassif M, de Vries AG, Weevers A, Scholte M, Spaargaren R, Wykrzykowska JJ, Tijssen JG, de Winter RJ, Koch KT. First-in-man evaluation of the novel balloon delivery system STENTYS Xposition S for the self-apposing coronary artery stent: impact on longitudinal geographic miss during stenting. EuroIntervention. 2016 Mar;11(12):1341-5. doi: 10.4244/EIJY15M05_07. | |
| 25983152 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Incident rate of stent thrombosis |
| 12 months |
| Target lesion revascularization | Incident rate of target lesion revascularization | 12 months |
| Unplanned hospitalization for unstable angina | Incident rate of unplanned hospitalization for unstable angina | 12 months |
| Procedural and in-hospital complications | Incident rate of periprocedural myocardial infarction, bleedings and access site complication, failure to cross stent struts with guidewire in the treatment of bifurcation, failure to delivery the stent, contrast-induced nephropathy | 30 days |
| Bleeding events | Incident rate of bleedings classified according to the BARC criteria | 12 months |
| Principal Investigator |
| Bernardo Cortese, MD | Interventional Cardiology, A.O. Fatebenefratelli Milano, Italy | Principal Investigator |
| Ferrarotto Hospital, University of Catania | Recruiting | Catania | Italy |
|
| Division of Cardiology, ASL TO4 | Recruiting | Cirié | Italy |
|
| Division of Cardiology, Santa Maria dei Battuti Hospital | Recruiting | Conegliano | Italy |
|
| Division of Cardiology, Ospedale Civile di Legnano - ASST Ovest Mi | Recruiting | Legnano | Italy |
|
| Interventional Cardiology, Azienda Ospedaliera Fatebenefratelli | Recruiting | Milan | Italy |
|
| Division of Cardiology, Federico II University | Recruiting | Naples | Italy |
|
| Division of Cardiology, Santa Corona Hospital | Recruiting | Pietra Ligure | Italy |
|
| Division of Cardiology, Fondazione Toscana G Monasterio | Recruiting | Pisa | Italy |
|
| Division of Cardiology, Policlinico Umberto I, La Sapienza University | Recruiting | Roma | Italy |
|
| Division of Cardiology, ASST Bergamo Ovest | Recruiting | Treviglio | Italy |
|
| AO Città della Salute e della Scienza | Recruiting | Turin | 10126 | Italy |
|
| Cardiology Department, Manipal Klang Hospital | Recruiting | Kuala Selangor | Malaysia |
|
| Division of Cardiology, Medical University of Silesia | Recruiting | Katowice | Poland |
|
| Background |
| Pyxaras SA, Schmitz T, Naber CK. The STENTYS Self-Apposing(R) stent. EuroIntervention. 2015;11 Suppl V:V147-8. doi: 10.4244/EIJV11SVA34. No abstract available. |
| 22514149 | Background | Farooq V, Gomez-Lara J, Brugaletta S, Gogas BD, Garcia-Garcia HM, Onuma Y, van Geuns RJ, Bartorelli A, Whitbourn R, Abizaid A, Serruys PW. Proximal and distal maximal luminal diameters as a guide to appropriate deployment of the ABSORB everolimus-eluting bioresorbable vascular scaffold: a sub-study of the ABSORB Cohort B and the on-going ABSORB EXTEND Single Arm Study. Catheter Cardiovasc Interv. 2012 May 1;79(6):880-8. doi: 10.1002/ccd.23177. Epub 2011 Oct 5. |
| 11785994 | Background | Uren NG, Schwarzacher SP, Metz JA, Lee DP, Honda Y, Yeung AC, Fitzgerald PJ, Yock PG; POST Registry Investigators. Predictors and outcomes of stent thrombosis: an intravascular ultrasound registry. Eur Heart J. 2002 Jan;23(2):124-32. doi: 10.1053/euhj.2001.2707. |
| 26340130 | Background | Yew KL, Kang Z. First-in-man unprotected left main stenting with Stentys Xposition S self-apposing sirolimus eluting stent and optical coherence tomography guidance: The emerging panacea for left main intervention. Int J Cardiol. 2015 Dec 15;201:628-30. doi: 10.1016/j.ijcard.2015.08.035. Epub 2015 Aug 4. No abstract available. |
| 26188831 | Background | Buccheri D, Orrego PS, Cortese B. Drug-eluting stent treatment of left main coronary artery disease: the case for a sirolimus-eluting, autoexpandable alternative. An optical coherence tomography analysis. Int J Cardiol. 2015 Nov 15;199:119-20. doi: 10.1016/j.ijcard.2015.07.006. Epub 2015 Jul 11. No abstract available. |
| 26865444 | Background | van Geuns RJ, Yetgin T, La Manna A, Tamburino C, Souteyrand G, Motreff P, Koch KT, Vrolix M, IJsselmuiden A, Amoroso G, Berland J, Montalescot G, Teiger E, Christiansen EH, Spaargaren R, Wijns W. STENTYS Self-Apposing sirolimus-eluting stent in ST-segment elevation myocardial infarction: results from the randomised APPOSITION IV trial. EuroIntervention. 2016 Feb;11(11):e1267-74. doi: 10.4244/EIJV11I11A248. |
| 26666346 | Background | Yew KL. Longitudinal stent foreshortening of Stentys Xposition S self-apposing stents and its impact on overlapping stenting strategy. Int J Cardiol. 2016 Feb 1;204:187-8. doi: 10.1016/j.ijcard.2015.11.176. Epub 2015 Nov 25. No abstract available. |
| 30298593 | Derived | Montefusco A, D'Ascenzo F, Gili S, Smolka G, Chieffo A, Baumbach A, Escaned J, Sganzerla P, Tomassini F, Secco GG, Ugo F, Tamburino C, Nicolino A, Mancone M, Poli A, Yew KL, Cirillo P, Wanha W, Pastormerlo LE, di Summa R, Sardella G, Colombo A, Gaita F, Cortese B. Self-expandable sirolimus-eluting stents compared to second-generation drug-eluting stents for the treatment of the left main: A propensity score analysis from the SPARTA and the FAILS-2 registries. Catheter Cardiovasc Interv. 2019 Feb 1;93(2):208-215. doi: 10.1002/ccd.27809. Epub 2018 Oct 8. |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |