Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Anal Acoustic Reflectometry (AAR) is a reliable and reproducible technique that has been studied in our department over the last 6 years. Sound waves pass into a balloon placed in the anal canal and are used to measure the cross-sectional area. By gradually increasing and decreasing the pressure in the balloon the investigators can measure the pressure at which the cross-sectional area starts to increase and decrease, and the anal canal starts to open and close. This assessment mimics the natural opening and closing of the anal canal and the effect of squeezing the muscles.
The gold standard investigation of the anal sphincter muscles has been manometry which measures anal canal pressure at rest and during squeeze. However, it has limitations. In previous studies AAR has shown promise in the assessment of faecal incontinence and, that unlike manometry, it has been able to distinguish between different types of incontinence.
The Recto-anal Inhibitory Reflex (RAIR) is a normal response when the rectum fills with faeces, fluid or air, whereby there is a change in the pressures within the anal canal to determine the type of contents. This can be absent or altered in patients who have difficulty in opening their bowels. The RAIR is currently measured by anal manometry using a 4.9mm catheter, resulting in an anal canal which is already partially opened prior to the measurement, and potentially distorted.
AAR is considered a catheter free technique as the balloon has a cross-sectional area of only 0.4mm2 when collapsed. The investigators propose to measure the RAIR using a 1.7mm diameter catheter alongside the AAR balloon to determine the effect that its placement has on the recorded parameters of AAR. This aims to improve our understanding of the opening and closing of the anal canal in response to distension of the rectum.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pelvic Floor Dysfunction | Observational study where patients with pelvic floor dysfunction undergo three AAR measurements. One at baseline, one with the catheter alongside and a third with the rectal balloon inflated. No intervention is performed Note, that initial inclusion of Squeeze parameters was detailed in error, these were not compared in this study and were compared in previous study |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Opening Pressure | Measurements of differences in Opening pressure (Op - cm H2O) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
| Opening Elastance | Measurements of differences in Opening Elastance (Oe - cm H2O/mm2) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
| Closing Pressure | Measurements of differences in Closing Pressure (Cp - cm H2O) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
| Closing Elastance | Measurements of differences in Closing Elastance (Ce - cm H2O/mm2) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
| Hysteresis | Measurements of differences in Hysteresis (%) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). Hysteresis is the extent of energy expenditure during opening and closing of the anal canal and represents the difference between opening and closing pressure and is expressed as a percentage |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients presenting to the pelvic floor clinic and neurogastroenterology with symptoms of pelvic floor dysfunction
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Karen J Telford, MBChBMDFRCS | University Hospital of South Manchester | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Hospital of South Manchester | Manchester | Greater Manchester | M23 9LT | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23506115 | Background | Klarskov N, Saaby ML, Lose G. A faster urethral pressure reflectometry technique for evaluating the squeezing function. Scand J Urol. 2013 Dec;47(6):529-33. doi: 10.3109/21681805.2013.776629. Epub 2013 Mar 19. | |
| 23132420 | Background | Hornung BR, Mitchell PJ, Carlson GL, Klarskov N, Lose G, Kiff ES. Comparative study of anal acoustic reflectometry and anal manometry in the assessment of faecal incontinence. Br J Surg. 2012 Dec;99(12):1718-24. doi: 10.1002/bjs.8943. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Pelvic Floor Dysfunction | Observational study where patients with pelvic floor dysfunction undergo three AAR measurements. One at baseline, one with the catheter alongside and a third with the rectal balloon inflated. No intervention is performed |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Pelvic Floor Dysfunction | Observational study where patients with pelvic floor dysfunction undergo three AAR measurements. One at baseline, one with the catheter alongside and a third with the rectal balloon inflated. No intervention is performed |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Median |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Opening Pressure | Measurements of differences in Opening pressure (Op - cm H2O) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | Posted | Median | Full Range | cmH2O | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Pelvic Floor Dysfunction | Observational study where patients with pelvic floor dysfunction undergo three AAR measurements. One at baseline, one with the catheter alongside and a third with the rectal balloon inflated. No intervention is performed |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Nick Heywood | University Hospital of South Manchester | +447739002473 | nheywood@doctors.org.uk |
Not provided
| ID | Term |
|---|---|
| D004688 | Encopresis |
| D012005 | Rectal Prolapse |
| ID | Term |
|---|---|
| D012817 | Signs and Symptoms, Digestive |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D001526 | Behavioral Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
| during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
| 22457059 | Background | Saaby ML, Klarskov N, Lose G. Urethral pressure reflectometry before and after tension-free vaginal tape. Neurourol Urodyn. 2012 Nov;31(8):1231-5. doi: 10.1002/nau.22239. Epub 2012 Mar 27. |
| 22381095 | Background | Klarskov N. Urethral pressure reflectometry. A method for simultaneous measurements of pressure and cross-sectional area in the female urethra. Dan Med J. 2012 Mar;59(3):B4412. |
| 22228166 | Background | Mitchell PJ, Klarskov N, Telford KJ, Hosker GL, Lose G, Kiff ES. Viscoelastic assessment of anal canal function using acoustic reflectometry: a clinically useful technique. Dis Colon Rectum. 2012 Feb;55(2):211-7. doi: 10.1097/DCR.0b013e31823b2499. |
| 21825892 | Background | Mitchell PJ, Klarskov N, Telford KJ, Hosker GL, Lose G, Kiff ES. Anal acoustic reflectometry: a new reproducible technique providing physiological assessment of anal sphincter function. Dis Colon Rectum. 2011 Sep;54(9):1122-8. doi: 10.1097/DCR.0b013e318223fbcb. |
| 22235880 | Background | Cheeney G, Nguyen M, Valestin J, Rao SS. Topographic and manometric characterization of the recto-anal inhibitory reflex. Neurogastroenterol Motil. 2012 Mar;24(3):e147-54. doi: 10.1111/j.1365-2982.2011.01857.x. Epub 2012 Jan 11. |
| 32770704 | Derived | Heywood NA, Sharma A, Kiff ES, Klarskov N, Telford KJ. Placement of a fine-bore rectal balloon catheter in the anal canal does not affect anal sphincter pressures: improving our understanding of physiological function with anal acoustic reflectometry. Colorectal Dis. 2020 Nov;22(11):1626-1631. doi: 10.1111/codi.15300. Epub 2020 Aug 30. |
| 32367609 | Derived | Heywood NA, Sharma A, Kiff ES, Klarskov N, Telford KJ. A novel method for measurement of the recto-anal inhibitory reflex using anal acoustic reflectometry. Colorectal Dis. 2020 Nov;22(11):1632-1641. doi: 10.1111/codi.15110. Epub 2020 Sep 23. |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| Units | Counts |
|---|---|
| Participants |
|
|
| Primary | Opening Elastance | Measurements of differences in Opening Elastance (Oe - cm H2O/mm2) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | Posted | Median | Full Range | cmH2O/mm2 | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
|
|
|
| Primary | Closing Pressure | Measurements of differences in Closing Pressure (Cp - cm H2O) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | Posted | Median | Full Range | cmH2O | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
|
|
|
| Primary | Closing Elastance | Measurements of differences in Closing Elastance (Ce - cm H2O/mm2) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). | Posted | Median | Full Range | cmH2O/mm2 | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
|
|
|
| Primary | Hysteresis | Measurements of differences in Hysteresis (%) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR). Hysteresis is the extent of energy expenditure during opening and closing of the anal canal and represents the difference between opening and closing pressure and is expressed as a percentage | Posted | Median | Full Range | percent | during single study visit- measurement taken prior to balloon inflation and post balloon inflation |
|
|
|
| 0 |
| 40 |
| 0 |
| 40 |
| 0 |
| 40 |
Not provided
Not provided
Not provided
| D001519 | Behavior |
| D019960 | Elimination Disorders |
| D001523 | Mental Disorders |
| D012002 | Rectal Diseases |
| D007410 | Intestinal Diseases |
| D005767 | Gastrointestinal Diseases |
| D004066 | Digestive System Diseases |
| D056887 | Pelvic Organ Prolapse |
| D011391 | Prolapse |
| D020763 | Pathological Conditions, Anatomical |