Not provided
The Canadian Pediatric Society recently published guidelines to monitor bilirubin levels and as part of standard of care all hospitalized newborns are routinely monitored for the development of high bilirubin or jaundice every 8-12 hours. One device approved and used in both Canada and the United States is the Draeger Jaundice Meter JM-103, a non-invasive medical device. It has been proven to be effective in patients >35 weeks gestational age. Recently the JM-103 has been upgraded to include a bigger touch screen, greater storage and functionality. The rest of the features of the JM-103 and JM-105 are identical. In order to test the accuracy of the JM-105 neonates from ≥ 24 weeks gestational age who have or have not undergone phototherapy will be prospectively monitored for transcutaneous bilirubin (TcB) using the JM-105. The measurements will be compared to a physician-ordered total serum bilirubin (TSB).
Hyperbilirubinemia is a condition that occurs in newborns when there is too much bilirubin in the blood. It is the most common cause of newborns being readmitted to the hospital. It may be harmless or harmful depending on what the cause is and how bad it is. The serum level of bilirubin required for jaundice varies with infants skin tones and body region, however jaundice usually becomes visible in the white part of the eye at smaller levels. Although jaundice in newborn is generally not harmful, it is important to monitor newborns to identify those that are at risk of developing a neurological dysfunction from high bilirubin levels. As part of standard of care all hospitalized newborns are routinely monitored for the development of jaundice by nursing staff and physicians every 8-12 hours. Although jaundice in newborns can usually be detected by lightening/whitening in the skin with digital pressure, this method of visual estimation is very inaccurate and unreliable. Transcutaneous bilirubin measurements are non-invasive and has proven to be equivalent to total serum bilirubin measurements. The JM-103 has been proven to be an effective TcB measure in ethnically diverse populations for patients >35 weeks gestational age. The JM-105 has been upgraded from the JM-103 with greater efficiency and accuracy. The basic function is the same but has been improved with a larger touch screen, data storage and transmission functionality.
This prospective multi-centre study will be conducted to determine the diagnostic accuracy and performance of the use of the JM-105 in providing transcutaneous bilirubin measurements to estimate serum total bilirubin in neonates ≥ 24 weeks of gestational age who have or have not undergone phototherapy. The study will compare each of the measurements of transcutaneous bilirubin (TcB) obtained for 10 days via the JM-105 device with a neonatology team-ordered series of serum total bilirubin (TSB) measured by high-performance liquid chromatography.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| JM-105 | Experimental | Within 15 minutes of each ordered blood sample 2 TcB measurements will be performed using the JM-105 on the sternum and forehead. Subject's participation will end after a 10 day period. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| JM-105 | Device | Measurement of TcB via the JM-105 device |
|
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy of TcB measured with the JM-105 device in predicting the Serum Bilirubin measurements performed on blood samples | Primary objective is to determine the accuracy of TcB measured with the JM-105 device in predicting the Serum Bilirubin measurements performed on blood samples from heel sticks or from peripheral line in neonates ≥ 24 weeks of gestational Age who are currently undergoing or have undergone phototherapy as a Screening and Monitoring device for hyperbilirubinemia | Within 15 minutes of blood sample taking |
| Measure | Description | Time Frame |
|---|---|---|
| Normalized curve of TSB measurements using the JM-105 | The secondary objective is to determine a normalized curve of TSB measurements using the JM-105. | Within 15 minutes of blood sample taking |
| Influence of phototherapy on TSB measurements |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Sgro, MD | Unity Health Toronto | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Saint Michael's Hospital | Toronto | Ontario | M5B1W8 | Canada | ||
| Mount Sinai Hospital |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 34139689 | Derived | Jegathesan T, Campbell DM, Ray JG, Shah V, Berger H, Hayeems RZ, Sgro M; NeoHBC. Transcutaneous versus Total Serum Bilirubin Measurements in Preterm Infants. Neonatology. 2021;118(4):443-453. doi: 10.1159/000516648. Epub 2021 Jun 17. |
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Dec 16, 2019 | |
| Reset | Jan 2, 2020 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Dec 16, 2019 | Jan 2, 2020 |
| ID | Term |
|---|---|
| D006932 | Hyperbilirubinemia |
| D007567 | Jaundice, Neonatal |
| ID | Term |
|---|---|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D051556 | Hyperbilirubinemia, Neonatal |
| D007232 | Infant, Newborn, Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The Impact of phototherapy on TSB measurements will be explored.
| Within 15 minutes of blood sample taking |
| Toronto |
| Ontario |
| M5G 1X5 |
| Canada |
| Hamilton Health Science Centre | Toronto | Ontario | Canada |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |