Low flow anesthesia (LFA) is used less than desirable, partly because one has considered that there might be danger of underdosing of anesthesia gas and thus risk of awareness under anesthesia.LFA has several advantages such as reducing loss of moisture and heat in the inhaled air under anesthesia and to reduce the consumption of anesthetic gas. A few anesthesia machines include an automatic gas control system: the Aisys machine, by GE Healthcare (Madison, WI, USA), and the Flow-i machine, by Maquet (Sweden).
Since these machines were introduced, only a few studies have reported their functionality and effect on gas consumption. 20 to 55% reduction of gas consumption was found. The potential reduction may have been underestimated because in the majority of cases a FGF higher than 1 l/min was still used.
In this study the consumption of anesthetic gas (desflurane) delivered by two different anesthesia machines (Aisys and Flow-i) will be compared, with and without gas control delivery systems. Gas consumption and the time needed to reach the target level of anesthetic gas concentration will be assessed. Data needed will be collected directly from the anesthesia machine, PICIS ( Electronic anesthesia record) and EPJ (Electronic patient journal). The results of this study are of interest for intraoperative ventilation and of economic and ecological interest
.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Aisys with Et control | Experimental | the ventilation modus will be pressure control ventilation with volume guarantee (PCV-VG). Settings: tidal volume (TV) 7-9 ml/kg BW, respiratory rate (RR) 12 -14/min, and 8-10 cmH2O positive end expiratory pressure (PEEP). Target for end expired desflurane concentration (F A des) is set to 4.2%, and target for end expired oxygen (F AO2) is set to 35%. |
|
| Aisys conventional ventilation | Active Comparator | 50% oxygen and 50% air in 1 liter FGF will be administered. To be started with a FGF of 5l/min and vaporizer setting at 6 Vol% for 5 min. Then the FGF will be reduced to 1 l/min. 25 min later the vaporizer setting will be reduced to 5.5 Vol % for the rest of the study period. Ventilation modus for this group will be the same as for 'Aisys with PCV-VG' |
|
| Flow-i with ACG | Experimental | the following parameters will be preset: FIO2= 40%; end expired gas concentration (FA des) to 4.2%; speed 6; and ventilation modus = pressure regulated volume control (PRVC) with tidal volume (TV) 7-9 ml/kg BW, respiratory rate (RR)12-14/min, and 8-10 cmH2O positive end expiratory pressure (PEEP). |
|
| Flow-I conventional ventilation | Active Comparator | 50% oxygen and 50% air in 1 liter FGF will be administered. To be started with a FGF of 5l/min and vaporizer setting at 6 Vol% for 5 min. Then the FGF will be reduced to 1 l/min. 25 min later the vaporizer setting will be reduced to 5.5 Vol % for the rest of the study period. Ventilation modus for this group will be the same as for 'Flow-i with ACG' |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Aisys with Et control | Device |
| ||
| Aisys conventional |
| Measure | Description | Time Frame |
|---|---|---|
| gas consumption in ml/hr | 1 hour |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Patients who are included in the study can be excluded for the following reasons:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| PÃ¥l Klepstad, PhD MD | St. Olavs Hospital | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Anesthesia, St.Olavs University Hospital | Trondheim | 7006 | Norway |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D052801 | Male Urogenital Diseases |
| D052776 | Female Urogenital Diseases |
| D053120 | Respiratory Aspiration |
| ID | Term |
|---|---|
| D000091642 | Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Flow-i with ACG | Device |
|
| Flow-i conventional | Device |
|
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |