Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study was a pilot, safety, and pharmacokinetic study of MB-102 versus iohexol and the use of the non-invasive optical renal function monitor (ORFM) device in normal and compromised renal function participants with different skin color types.
The objectives of this study were to evaluate the safety and tolerability of single and multiple doses of MB-102 in participants with normal and impaired kidney function; to determine plasma pharmacokinetics of MB-102 compared to the pharmacokinetics of iohexol in participants with normal and impaired kidney function; to demonstrate that MB-102-transdermal-fluorescence-measured glomerular filtration rate (GFR) using the optical renal function monitor (ORFM) Brilliance device is aligned with MB-102 plasma GFR; to evaluate the safety and effectiveness of the ORFM investigational medical device prototypes QuantumLeap, Radiance, and Brilliance for the non-invasive transdermal fluorescent detection of MB-102 in participants with a range of skin color types; and to determine the optimal dose of MB-102 for non-invasive measurement.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Normal-CKD Stage 2/QuantumLeap | Experimental | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
|
| CKD Stage 3-4/QuantumLeap | Experimental | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-4), and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
|
| Normal-CKD Stage 2/Radiance | Experimental | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| CKD Stage 3-5/Radiance |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| MB-102-- single dose of 4 µmol/kg | Drug | 4 µmol/kg administered by intravenous injection over 30 seconds, followed by a 10 mL normal saline flush administered intravenously over 30 seconds. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Participants With Treatment-Emergent Adverse Events | An adverse event is defined as any untoward medical occurrence, unintended disease or injury, or untoward clinical signs (including abnormal laboratory findings) in subjects, temporally associated with the use of a medicinal product, whether or not related to the investigational medical device or drug. | From the time of dosing through the follow-up visit, up to 10 days |
| Measure | Description | Time Frame |
|---|---|---|
| Maximum Plasma Concentration (Cmax) of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Maximum plasma concentration (Cmax; measured in ng/mL) was directly determined from the concentration-time data. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
Not provided
INCLUSION CRITERIA
Main Criteria for Inclusion (Quantum Leap and Radiance device)
Age > 22 years - male or female
Participants willing to comply with study requirements
Participants who have signed an informed consent form
Normal or non-clinically significant screening and baseline 12-lead electrocardiogram (ECG) in the opinion of the principal investigator (PI)
Adequate venous access sufficient to allow blood sampling per protocol requirements
Main Criteria for Inclusion (Brilliance device)
Age > 18 years - male or female
Participants willing to comply with study requirements
Participants who have signed an informed consent form
Normal or non-clinically significant screening and baseline 12-lead ECG in the opinion of the PI
Adequate venous access sufficient to allow blood sampling per protocol requirements
Normal-CKD Stage 2/QuantumLeap; Normal-CKD Stage 2/Radiance; Normal-CKD Stage 2/Brilliance algorithm optimization; Normal-CKD Stage 2/Brilliance sensor optimization; Normal-CKD Stage 2/Brilliance sensor optimization; and Normal-CKD Stage 2/Brilliance (1-2 sensors)
CKD Stage 3-4/QuantumLeap
Possess stable renal function in the opinion of the PI
Have eGFR (CKD-EPI equation) of 15 - 59 mL/min/1.73m^2 at the time of screening
Stable use of immunosuppressant medications (when applicable)
CKD Stage 3-5/Radiance; CKD Stage 3-5/Brilliance algorithm optimization; CKD Stage 3-5/Brilliance sensor validation; and CKD Stage 3-5/Brilliance 1-2 sensors
EXCLUSION CRITERIA
Main Criteria for Exclusion (QuantumLeap device)
Additional Exclusion: Normal-CKD Stage 2/QuantumLeap
• History of significant cardiovascular disease, heart failure, myocardial infarction in the past 3 months, pulmonary, hematologic, endocrine, hepatobiliary, nephrologic, immunologic, dermatologic, neurologic (including any history of stroke and/or seizure disorder), psychological, musculoskeletal disease, diagnosis of cancer with the past 2 years or deemed clinically significant or unstable by the Principal Investigator; Note: history of gallstones or kidney stones are not excluded so long as the condition is not acute within 30 days of dosing.
Additional Exclusion: CKD Stage 3-4/QuantumLeap
Main Criteria for Exclusion: (Radiance device)
Women who are pregnant, lactating or planning to become pregnant during the study, or women who are of childbearing potential unwilling to use a barrier method of birth control
o Males must be willing to practice abstinence or utilize adequate contraception from dosing day to at least 7 days post dose
Unable to have venous access placed in both arms
Recent donation or loss of blood or plasma: 100 mL to 499 mL within 30 days prior to the initial dose of the study medication; or more than 499 mL within 56 days prior to the initial dose of study medication
Participation in another interventional trial within 30 days of dosing or concurrently enrolled in any other medical research study which could impact the results of the study
History of drug or alcohol abuse within the past year
History of skin sensitivity to adhesives (e.g. Band-Aids, surgical tape)
History of severe allergic hypersensitivity reactions (unacceptable adverse events) or anaphylactoid reaction to any allergen including drugs, MB-102 and iohexol or other related (iodinated contrast media) products (intolerance to a drug is not considered a drug allergy)
NSAID use within 2 days of dosing day
History of coagulation disorders or bleeding disorders that in the judgement of the investigator places the subject at undue risks for study related procedures
Are homozygous for sickle cell disease
Have hyperthyroidism or current thyroid cancer
Have pheochromocytoma
Currently on Coumadin (warfarin) who have an INR >4 at Screening
Current history of AIDS or HIV
Current evidence of an active Hepatitis B or C infection. If the participant is Hepatitis C antibody positive, but the hepatitis C RNA is below the level of detection, they are considered immune and may be eligible for enrollment.
Site personnel immediately associated with the study or their immediate family members
Any characteristics which, in the opinion of the investigator, makes the subject a poor candidate for participation in the clinical trial
Prior exposure to MB-102
Significant scaring, tattoos or alterations in pigmentation on the sternum that would alter sensor readings versus other areas of the skin
Main Criteria for Exclusion: (Brilliance device)
Women who are pregnant, lactating or planning to become pregnant during the study, or women who are of childbearing potential unwilling to use a barrier method of birth control
o Males must be unwilling to practice abstinence or utilize adequate contraception from dosing day to at least 7 days post dose
Unable to have venous access
Recent donation or loss of blood or plasma: 100 mL to 499 mL within 30 days prior to the initial dose of the study medication; or more than 499 mL within 56 days prior to the initial dose of study medication
Participation in another interventional trial within 30 days of dosing or concurrently enrolled in any other medical research study which could impact the results of the study
History of drug or alcohol abuse within the past year
History of skin sensitivity to adhesives (e.g. Band-Aids, surgical tape)
History of severe allergic hypersensitivity reactions (unacceptable adverse events) or anaphylactoid reaction to any allergen including drugs, or MB-102 (intolerance to a drug is not considered a drug allergy)
NSAID use within 2 days of dosing day
History of coagulation disorders or bleeding disorders that in the judgement of the investigator places the subject at undue risks for study related procedures
Currently on Coumadin (warfarin) who have an INR >4 at Screening
Current history of AIDS or HIV
Current evidence of an active Hepatitis B or C infection. If the participant is Hepatitis C antibody positive, but the hepatitis C RNA is below the level of detection, they are considered immune and may be eligible for enrollment.
Site personnel immediately associated with the study or their immediate family members
Any characteristics which, in the opinion of the investigator, makes the participant a poor candidate for participation in the clinical trial
Significant scaring, tattoos or alterations in pigmentation on the sternum that would alter sensor readings versus other areas of the skin
Additional Exclusion: Normal-CKD Stage 2/Radiance; Normal-CKD Stage 2/Brilliance algorithm optimization; Normal-CKD Stage 2/Brilliance sensor optimization; Normal-CKD Stage 2/Brilliance sensor validation; and Normal-CKD Stage 2/Brilliance (1-2 sensors)
Additional Exclusion: CKD Stage 3-5/Radiance; CKD Stage 3-5/Brilliance algorithm optimization; CKD Stage 3-5/Brilliance sensor validation; and CKD Stage 3-5/Brilliance 1-2 sensors
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Richard B Dorshow, PhD | MediBeacon, Inc. | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Riverside Clinical Research | Edgewater | Florida | 32132 | United States | ||
| Orlando Clinical Research Center |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 39918882 | Derived | Dorshow RB, Debreczeny MP, Goldstein SL. GFR Measurement Using Transdermal Detection Methodology. J Am Soc Nephrol. 2025 Feb 7;36(8):1592-1602. doi: 10.1681/ASN.0000000639. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Safety Analysis Set: all participants who signed the informed consent form and received study drug
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Normal-CKD Stage 2/QuantumLeap | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jun 18, 2021 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Experimental |
MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| Normal-CKD Stage 2/Brilliance algorithm optimization | Experimental | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| CKD Stage 3-5/Brilliance algorithm optimization | Experimental | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| Normal-CKD Stage 2/Brilliance sensor optimization | Experimental | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| Normal-CKD Stage 2/Brilliance sensor validation | Experimental | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| CKD Stage 3-5/Brilliance sensor validation | Experimental | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| Normal-CKD Stage 2/Brilliance (1-2 sensors) | Experimental | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
|
| Normal-CKD Stage 2/Brilliance (1-2 sensors and Brilliance 2-part sensor) | Experimental | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
|
| Normal-CKD Stage 2/Brilliance (1-2 sensors and Brilliance 2-part sensor) and 2 doses MB-102 | Experimental | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
| CKD Stage 3-5/Brilliance 1-2 sensors | Experimental | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| MB-102-- single dose of 130 mg | Drug | 130 mg administered by intravenous injection over 30 seconds, followed by a 10 mL normal saline flush administered intravenously over 30 seconds. A subset of participants will receive two doses of MB-102, 12 hours apart. |
|
|
| MB-102-single dose of 130 mg or 2 doses of 130 mg 12 hours apart | Drug | 130 mg administered by intravenous injection over 30 seconds, followed by a 10 mL normal saline flush administered intravenously over 30 seconds. |
|
|
| MB-102-- two doses of 130 mg 24 hours apart | Drug | 4 µmol/kg administered by intravenous injection over 30 seconds, followed by a 10 mL normal saline flush administered intravenously over 30 seconds. A subset of participants will receive two doses of MB-102, 12 hours apart. |
|
|
| Iohexol | Drug | 5 mL of a 647 mg/mL solution administered by intravenous injection over 30 seconds, followed by a 10 mL normal saline flush administered intravenously over 30 seconds |
|
|
| QuantumLeap | Device | Optical Renal Function Monitor (ORFM) |
|
| Radiance | Device | Optical Renal Function Monitor (ORFM) |
|
| Brilliance (1 or 2 sensors) | Device | Optical Renal Function Monitor (ORFM) |
|
| Brilliance (2-part sensor) | Device | Optical Renal Function Monitor (ORFM) |
|
| Maximum Plasma Concentration (Cmax) of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Maximum plasma concentration (Cmax; measured in ng/mL) was directly determined from the concentration-time data. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Time to Maximum Plasma Concentration (Tmax) of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The time to maximum plasma concentration (Tmax; measured in minutes) was directly determined from the concentration-time data. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Time to Maximum Plasma Concentration (Tmax) of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The time to maximum plasma concentration (Tmax; measured in minutes) was directly determined from the concentration-time data. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| The Elimination Half-life of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The elimination half-life (the time required for the concentration of the drug to reach half of its original value) was calculated as t1/2 λz= ln(2)/ λz. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| The Elimination Half-life of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The elimination half-life (the time required for the concentration of the drug to reach half of its original value) was calculated as t1/2 λz= ln(2)/ λz. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Area Under the Plasma Concentration-time Curve From Time Zero to the Time of the Last Quantifiable Concentration for MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) was be estimated from time 0 to the last measurable concentration using noncompartmental analyses. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Area Under the Plasma Concentration-time Curve From Time Zero to the Time of the Last Quantifiable Concentration for Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) was be estimated from time 0 to the last measurable concentration using noncompartmental analyses. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Area Under the Plasma Concentration-time Curve From Time Zero to Infinity for MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) from time 0 to infinity was calculated as: AUC∞ = AUClast + LQC/λz where LQC is the predicted concentration (based on the terminal regression) at the time of the last measurable concentration. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Area Under the Plasma Concentration-time Curve From Time Zero to Infinity for Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) from time 0 to infinity was calculated as: AUC∞ = AUClast + LQC/λz where LQC is the predicted concentration (based on the terminal regression) at the time of the last measurable concentration. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Total Plasma Clearance of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Total plasma clearance (the volume of plasma cleared of the drug over time) was calculated as: Clp = Dose/ AUC∞. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Total Plasma Clearance of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Total plasma clearance (the volume of plasma cleared of the drug over time) was calculated as: Clp = Dose/ AUC∞. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| The Terminal Rate Constant for MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The terminal rate constant (λz) was determined by linear regression of the terminal linear phase of the log plasma concentration-time profile. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| The Terminal Rate Constant for Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The terminal rate constant (λz) was determined by linear regression of the terminal linear phase of the log plasma concentration-time profile. | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| Renal Clearance of MB-102 | Urine samples were collected pre-dose (time 0) and 5 mL urine samples were collected each time the subject voided. The total volume of urine excreted was recorded until 12 hours post-dose, and was analyzed using validated analytical methods. Renal clearance (the volume of plasma cleared of the drug by the kidneys over time) was calculated as: CLr = Ae/ AUClast, where Ae is the cumulative amount of analyte excreted in urine over the sampling interval. | Pre-dose and each time the participant voids up to 720 minutes post dose |
| Renal Clearance of Iohexol | Urine samples were collected pre-dose (time 0) and 5 mL urine samples were collected each time the subject voided. The total volume of urine excreted was recorded until 12 hours post-dose, and was analyzed using validated analytical methods. Renal clearance (the volume of plasma cleared of the drug by the kidneys over time) was calculated as: CLr = Ae/ AUClast, where Ae is the cumulative amount of analyte excreted in urine over the sampling interval. | Pre-dose and each time the participant voids up to 720 minutes post dose |
| Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Quantum Leap Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the QuantumLeap device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the QuantumLeap device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose |
| Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Radiance Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and will be analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the Radiance device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the Radiance device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose |
| Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Brilliance Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase in Participants With Normal-CKD Stage 2 Renal Function | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, and 480 minutes post dose, and were analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the Brilliance device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the Brilliance device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, and 480 minutes post dose |
| Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Brilliance Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase in Participants With CKD Stage 3-4 Renal Function | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) and 960, 1440, 1920, 2400, and 2880 (±30 min) minutes post dose, and were analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the Brilliance device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the Brilliance device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) and 960, 1440, 1920, 2400, and 2880 (±30 min) minutes post dose |
| Number of Participants With Adverse Events Related to the Use of the QuantumLeap Device | The number of participants with adverse events related to the use of the QuantumLeap device was documented. | From the time of dosing through the follow-up visit, up to 10 days |
| Number of Participants With Adverse Events Related to the Use of the Radiance Device | The number of participants with adverse events related to the use of the Radiance device was documented. | From the time of dosing through the follow-up visit, up to 10 days |
| Number of Participants With Adverse Events Related to the Use of the Brilliance Device | The number of participants with adverse events related to the use of the Brilliance device was documented. | From the time of dosing through the follow-up visit, up to 10 days |
| Orlando |
| Florida |
| 32809 |
| United States |
| Washington University School of Medicine | St Louis | Missouri | 63110 | United States |
| FG001 | CKD Stage 3-4/QuantumLeap | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-4), and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
| FG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| FG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| FG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| FG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| COMPLETED |
|
| NOT COMPLETED |
|
|
Safety Analysis Set: all participants who signed the informed consent form and received study drug
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Normal-CKD Stage 2/QuantumLeap | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
| BG001 | CKD Stage 3-4/QuantumLeap | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-4), and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
| BG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| BG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| BG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| BG013 | Total | Total of all reporting groups |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean | Standard Deviation | years |
| |||||||||||||||
| Sex: Female, Male | Count of Participants | Participants | No |
| |||||||||||||||
| Race (NIH/OMB) | Count of Participants | Participants | No |
| |||||||||||||||
| Region of Enrollment | Count of Participants | Participants | No |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Number of Participants With Treatment-Emergent Adverse Events | An adverse event is defined as any untoward medical occurrence, unintended disease or injury, or untoward clinical signs (including abnormal laboratory findings) in subjects, temporally associated with the use of a medicinal product, whether or not related to the investigational medical device or drug. | Safety Analysis Set: all participants who signed the informed consent form and received study drug | Posted | Count of Participants | Participants | No | From the time of dosing through the follow-up visit, up to 10 days |
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Maximum Plasma Concentration (Cmax) of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Maximum plasma concentration (Cmax; measured in ng/mL) was directly determined from the concentration-time data. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | ng/mL | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Maximum Plasma Concentration (Cmax) of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Maximum plasma concentration (Cmax; measured in ng/mL) was directly determined from the concentration-time data. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | ng/mL | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Time to Maximum Plasma Concentration (Tmax) of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The time to maximum plasma concentration (Tmax; measured in minutes) was directly determined from the concentration-time data. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | minutes | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Time to Maximum Plasma Concentration (Tmax) of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The time to maximum plasma concentration (Tmax; measured in minutes) was directly determined from the concentration-time data. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | minutes | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | The Elimination Half-life of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The elimination half-life (the time required for the concentration of the drug to reach half of its original value) was calculated as t1/2 λz= ln(2)/ λz. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | minutes | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | The Elimination Half-life of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The elimination half-life (the time required for the concentration of the drug to reach half of its original value) was calculated as t1/2 λz= ln(2)/ λz. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | minutes | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Area Under the Plasma Concentration-time Curve From Time Zero to the Time of the Last Quantifiable Concentration for MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) was be estimated from time 0 to the last measurable concentration using noncompartmental analyses. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | ng*min/mL | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Area Under the Plasma Concentration-time Curve From Time Zero to the Time of the Last Quantifiable Concentration for Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) was be estimated from time 0 to the last measurable concentration using noncompartmental analyses. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | ng*min/mL | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Area Under the Plasma Concentration-time Curve From Time Zero to Infinity for MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) from time 0 to infinity was calculated as: AUC∞ = AUClast + LQC/λz where LQC is the predicted concentration (based on the terminal regression) at the time of the last measurable concentration. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | ng*min/mL | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Area Under the Plasma Concentration-time Curve From Time Zero to Infinity for Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The area under the plasma concentration-time curve (ng*min/mL) from time 0 to infinity was calculated as: AUC∞ = AUClast + LQC/λz where LQC is the predicted concentration (based on the terminal regression) at the time of the last measurable concentration. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | ng*min/mL | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Total Plasma Clearance of MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Total plasma clearance (the volume of plasma cleared of the drug over time) was calculated as: Clp = Dose/ AUC∞. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | mL/minute | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Total Plasma Clearance of Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Total plasma clearance (the volume of plasma cleared of the drug over time) was calculated as: Clp = Dose/ AUC∞. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | mL/minute | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | The Terminal Rate Constant for MB-102 | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The terminal rate constant (λz) was determined by linear regression of the terminal linear phase of the log plasma concentration-time profile. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | 1/minutes | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | The Terminal Rate Constant for Iohexol | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. The terminal rate constant (λz) was determined by linear regression of the terminal linear phase of the log plasma concentration-time profile. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | 1/minutes | Pre-dose and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose. |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Renal Clearance of MB-102 | Urine samples were collected pre-dose (time 0) and 5 mL urine samples were collected each time the subject voided. The total volume of urine excreted was recorded until 12 hours post-dose, and was analyzed using validated analytical methods. Renal clearance (the volume of plasma cleared of the drug by the kidneys over time) was calculated as: CLr = Ae/ AUClast, where Ae is the cumulative amount of analyte excreted in urine over the sampling interval. | All participants who received study drug and had no major protocol deviations. | Posted | Mean | Standard Deviation | mL/minute | Pre-dose and each time the participant voids up to 720 minutes post dose |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Renal Clearance of Iohexol | Urine samples were collected pre-dose (time 0) and 5 mL urine samples were collected each time the subject voided. The total volume of urine excreted was recorded until 12 hours post-dose, and was analyzed using validated analytical methods. Renal clearance (the volume of plasma cleared of the drug by the kidneys over time) was calculated as: CLr = Ae/ AUClast, where Ae is the cumulative amount of analyte excreted in urine over the sampling interval. | All participants who received study drug and had no major protocol deviations. Per protocol, those in the Brilliance device group did not receive iohexol. | Posted | Mean | Standard Deviation | mL/minute | Pre-dose and each time the participant voids up to 720 minutes post dose |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Quantum Leap Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and were analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the QuantumLeap device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the QuantumLeap device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | All participants who received study drug and had no major protocol deviations | Posted | Mean | Standard Deviation | Coefficient of determination, r-squared | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Radiance Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose, and will be analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the Radiance device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the Radiance device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | All participants who received study drug and had no major protocol deviations | Posted | Mean | Standard Deviation | Coefficient of determination, r-squared | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) minutes post dose |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Brilliance Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase in Participants With Normal-CKD Stage 2 Renal Function | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, and 480 minutes post dose, and were analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the Brilliance device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the Brilliance device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | All participants who received study drug and had no major protocol deviations | Posted | Mean | Standard Deviation | Coefficient of determination, r-squared | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, and 480 minutes post dose |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Correlation Between the Transdermal Fluorescence Intensity of MB-102 as Measured by the Brilliance Device and Plasma Concentration of MB-102 at Each Time Point in the Renal Excretion Phase in Participants With CKD Stage 3-4 Renal Function | Blood samples were collected pre-dose (time 0) and at 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) and 960, 1440, 1920, 2400, and 2880 (±30 min) minutes post dose, and were analyzed using validated analytical methods. Transdermal fluorescence intensity at the time of blood sampling as measured by the Brilliance device was documented, and the correlation between the transdermal fluorescence intensity of MB-102 as measured by the Brilliance device and the plasma concentration of MB-102 at each time point in the renal excretion phase was calculated. | All participants who received study drug and had no major protocol deviations | Posted | Mean | Standard Deviation | Coefficient of determination, r-squared | Pre-dose (time 0) and 5, 10, 15; (± 1 or 2 min), 30, 60, 90, 120, 180, 240, 300 (±5 min), 360, 480, 600 and 720 (±10 min) and 960, 1440, 1920, 2400, and 2880 (±30 min) minutes post dose |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Number of Participants With Adverse Events Related to the Use of the QuantumLeap Device | The number of participants with adverse events related to the use of the QuantumLeap device was documented. | Safety Analysis Set: all participants who signed the informed consent form and received study drug | Posted | Count of Participants | Participants | No | From the time of dosing through the follow-up visit, up to 10 days |
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Number of Participants With Adverse Events Related to the Use of the Radiance Device | The number of participants with adverse events related to the use of the Radiance device was documented. | Safety Analysis Set: all participants who signed the informed consent form and received study drug | Posted | Count of Participants | Participants | No | From the time of dosing through the follow-up visit, up to 10 days |
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Secondary | Number of Participants With Adverse Events Related to the Use of the Brilliance Device | The number of participants with adverse events related to the use of the Brilliance device was documented. | Safety Analysis Set: all participants who signed the informed consent form and received study drug | Posted | Count of Participants | Participants | No | From the time of dosing through the follow-up visit, up to 10 days |
|
Treatment-emergent adverse events were collected from the time of dosing through the follow-up visit, up to 10 days
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Normal-CKD Stage 2/QuantumLeap | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. | 0 | 31 | 0 | 31 | 7 | 31 |
| EG001 | CKD Stage 3-4/QuantumLeap | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-4), and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. | 0 | 29 | 0 | 29 | 5 | 29 |
| EG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 20 | 0 | 20 | 2 | 20 |
| EG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 40 | 0 | 40 | 0 | 40 |
| EG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 9 | 0 | 9 | 1 | 9 |
| EG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 7 | 0 | 7 | 1 | 7 |
| EG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 18 | 0 | 18 | 2 | 18 |
| EG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 30 | 0 | 30 | 0 | 30 |
| EG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 18 | 0 | 18 | 1 | 18 |
| EG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. | 0 | 12 | 0 | 12 | 2 | 12 |
| EG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. MB-102-single dose of 130 mg or 2 doses of 130 mg 12 hours apart: 130 mg administered by intravenous injection over 30 seconds, followed by a 10 mL normal saline flush administered intravenously over 30 seconds. Brilliance (1 or 2 sensors): Optical Renal Function Monitor (ORFM) Brilliance (2-part sensor): Optical Renal Function Monitor (ORFM) | 0 | 4 | 0 | 4 | 1 | 4 |
| EG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 4 | 0 | 4 | 1 | 4 |
| EG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. | 0 | 12 | 0 | 12 | 2 | 12 |
Not provided
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| Nausea | Gastrointestinal disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Application site discoloration | General disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Application site erythema | General disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Injection site bruising | General disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Injection site extravasation | General disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Oedema peripheral | General disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Conjunctivitis | Infections and infestations | MedDRA (18.0) | Systematic Assessment |
| |
| Headache | Nervous system disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Oropharyngeal pain | Respiratory, thoracic and mediastinal disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Rash | Skin and subcutaneous tissue disorders | MedDRA (18.0) | Systematic Assessment |
| |
| Hot flush | Vascular disorders | MedDRA (18.0) | Systematic Assessment |
|
MediBeacon requests that no presentation/publication occur until after the first publication of study results or until 1 yr after a study is completed/terminated early, whichever occurs first. Proposed results publication/disclosure must be given to Sponsor for review at least 45 days prior to the date of submission. If a patent application is to be filed, both the Institution and the Sponsor will defer publication or other disclosure for a period of time, not to exceed an additional 60 days.
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Richard B Dorshow, PhD | MediBeacon | 314-735-0967 | rbdorshow@medibeacon.com |
| Jun 19, 2023 |
| Prot_SAP_000.pdf |
| ID | Term |
|---|---|
| D058186 | Acute Kidney Injury |
| ID | Term |
|---|---|
| D051437 | Renal Insufficiency |
| D007674 | Kidney Diseases |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| C000657342 | relmapirazin |
| D007472 | Iohexol |
| ID | Term |
|---|---|
| D014283 | Triiodobenzoic Acids |
| D007463 | Iodobenzoates |
| D001565 | Benzoates |
| D000146 | Acids, Carbocyclic |
| D002264 | Carboxylic Acids |
| D009930 | Organic Chemicals |
| D001555 | Benzene Derivatives |
| D006841 | Hydrocarbons, Aromatic |
| D006844 | Hydrocarbons, Cyclic |
| D006838 | Hydrocarbons |
Not provided
Not provided
| Male |
|
| Asian |
|
| Native Hawaiian or Other Pacific Islander |
|
| Black or African American |
|
| White |
|
| More than one race |
|
| Unknown or Not Reported |
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor).The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | Normal-CKD Stage 2/Brilliance Algorithm Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | CKD Stage 3-5/Brilliance Algorithm Optimization | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Algorithm optimization of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG006 | Normal-CKD Stage 2/Brilliance Sensor Optimization | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG007 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG009 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG010 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG011 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG012 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG002 | Normal-CKD Stage 2/Radiance | MB-102 and iohexol administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | CKD Stage 3-5/Radiance | MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Radiance ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
MB-102 and iohexol administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-4), and fluorescence measured by the QuantumLeap ORFM device. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. In order to determine the optimal dose of MB-102, participants may have received different doses. |
|
|
|
|
MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG002 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG004 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG005 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| OG001 |
| CKD Stage 3-5/Brilliance Sensor Validation |
MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG002 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|
| Units | Counts |
|---|---|
| Participants |
|
|
| Participants |
|
|
| Normal-CKD Stage 2/Brilliance Sensor Optimization |
MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Sensor optimization of the Brilliance device was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG003 | Normal-CKD Stage 2/Brilliance Sensor Validation | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG004 | CKD Stage 3-5/Brilliance Sensor Validation | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. Validation of the Brilliance sensor was conducted. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG005 | Normal-CKD Stage 2/Brilliance (1-2 Sensors) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG006 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) | MB-102 administered to participants with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. A subset of participants in this arm received two doses of MB-102, 12 hours apart. |
| OG007 | Normal-CKD Stage 2/Brilliance (1-2 Sensors and Brilliance 2-part Sensor) and 2 Doses MB-102 | Two doses of MB-102 administered to participants 12 hours apart, with normal to chronic kidney disease (CKD) Stage 2 renal function, and fluorescence measured by the Brilliance ORFM device (1-2 sensors and 2-part sensor). The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
| OG008 | CKD Stage 3-5/Brilliance 1-2 Sensors | MB-102 administered to participants with impaired renal function (chronic kidney disease (CKD) Stage 3-5), and fluorescence measured by the Brilliance ORFM device. The optimized algorithm and final device design of the Brilliance device was tested. Approximately half of the participants were to be enrolled with Fitzpatrick Scale Type I, II or III, and half with Type IV, V and VI skin color type. |
|
|