In the past years several shoulder reconstruction systems with different types of prostheses and fixation methods have been developed to improve shoulder arthroplasty, trying to cover a wide range of pathologies and revision situations. The aim of the present study is to report radiological and clinical outcome with a stemless shoulder implant with hollow screw fixation.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Total shoulder arthroplasty (TSA) | Replacement of humeral head and glenoid |
| |
| Hemi shoulder arthroplasty (HSA) | Replacement of humeral head only |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Total shoulder arthroplasty (TSA) | Procedure | stemless humeral head implant: Eclipse™ (Arthrex Inc., Naples, FL, USA) |
|
| Measure | Description | Time Frame |
|---|---|---|
| the Constant score | The Constant score is a validated outcome score assessing pain and function of the shoulder | 5 years |
| Radiological assessment to determine radiolucent areas and osteolysis around the humeral head | 5 years |
| Measure | Description | Time Frame |
|---|---|---|
| the Constant score | Change from baseline to 2 years postimplantation | |
| Radiological assessment to determine radiolucent areas and osteolysis around the humeral head | 2 years | |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Patients requiring hemi- or total shoulder arthroplasty
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29357861 | Derived | Heuberer PR, Brandl G, Pauzenberger L, Laky B, Kriegleder B, Anderl W. Radiological changes do not influence clinical mid-term outcome in stemless humeral head replacements with hollow screw fixation: a prospective radiological and clinical evaluation. BMC Musculoskelet Disord. 2018 Jan 22;19(1):28. doi: 10.1186/s12891-018-1945-6. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000072228 | Arthroplasty, Replacement, Shoulder |
| ID | Term |
|---|---|
| D019643 | Arthroplasty, Replacement |
| D001178 | Arthroplasty |
| D019637 | Orthopedic Procedures |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided
Not provided
Not provided
Not provided
| Hemi shoulder arthroplasty (HSA) | Procedure | stemless humeral head implant: Eclipse™ (Arthrex Inc., Naples, FL, USA) |
|
| Eclipse™ (Arthrex Inc., Naples, FL, USA) | Device | stemless humeral head implant |
|
| the Constant score |
| Change from baseline to 5 years postimplantation |
| the Constant score | 10 years |
| Radiological assessment to determine radiolucent areas and osteolysis around the humeral head | 10 years |
| the Constant score | 15-20 years |
| Radiological assessment to determine radiolucent areas and osteolysis around the humeral head | 15-20 years |
| D019651 | Plastic Surgery Procedures |
| D019919 | Prosthesis Implantation |