Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Fundació Eurecat | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Anterior Cruciate Ligament (ACL) injuries by trauma are a prevalent pathology. In the USA, about 200.000 injuries are estimated per year, half of which implicate a total rupture of the ligament. Data indicates that the number of ACL injuries is increasing in young athletes and presents a common problem, especially people playing agility sports.
One of the most widely used methods for the post-surgical mobilization after ACL is the use of Continuous Passive Motion (CPM) devices. These machines are meant to drain residual fluid from the articulation and maintain the mobility of the joint and muscles in the knee. Even though studies show that, an early mobilization after surgery is beneficial to the rehabilitation of the knee joint, recent studies are questioning the efficiency of the CPM when compared with the goal of application. While literature suggests that efficacy of CPM are related with the magnitude of knee flexion and the Range of Motion (ROM) achieved some studies show that the range of motion measured by the CPM is considerably less than the actual ROM.
As other therapy that provides an effective mobilization of the knee joint, the Specific Manual Physical Therapy method (Kaltenborn method) takes in account the physiological combination of rotation and gliding of the two joint surfaces. This technique mobilizes the femorotibial joint by controlling the tibial plateau anteroposterior during flexion and posteroanterior during extension of the knee. Therefore, in the past 30 years there are not studies comparing ROM measurements obtained with CPM and manual physical therapy methods.
It is hypothesized that the benefits of the early passive mobilization after ACL reconstructive surgery are diminished by the limited efficacy of currently used CPM devices. The aim of our study was to determine the range of motion achieved with the passive mobilization using a CPM device compared with a manual method (Kaltenborn method) and to assess that ROM measurements provided by the CPM correlates the real ROM.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| EXP 1: Manual mobilization / CPM | Active Comparator | Patients were subjected to a manual mobilization using the Kaltenborn approach, in which 15 tibiofemoral glides were applied by a physiotherapist. After a pause of 5 minutes, the patient was collocated in a commercially available CPM device (Kinetec Advanced Prima) and received 15 repetitions of flexo-extension. |
|
| EXP 2: CPM / Manual mobilization | Active Comparator | Patients were collocated in a commercially available CPM device (Kinetec Advanced Prima) and received 15 repetitions of flexo-extension. After a pause of 5 minutes, patients were subjected to a manual mobilization using the Kaltenborn approach, in which 15 tibiofemoral glides were applied by a physiotherapist. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CPM | Device | 15 repetitions of flexo-extensión with a commercially available CPM device (Kinetec Advanced Prima) |
|
| Measure | Description | Time Frame |
|---|---|---|
| Knee Range of Motion (ROM) angle | Maximum knee flexion angle minus the maximum knee extension angle obtained from 15 repetitions of flexo-extension. Measurements were obtained by CPM device and an external goniometer | Fifteen hours after surgery |
| Knee maximum flexion | Maximum knee flexion obtained form 15 repetitions of flexo-extensión. Measurements were obtained by CPM device and an external goniometer | Fifteen hours after surgery |
| Knee maximum extension | Maximum knee extension obtained form 15 repetitions of flexo-extensión. Measurements were obtained by CPM device and an external goniometer | Fifteen hours after surgery |
| Measure | Description | Time Frame |
|---|---|---|
| Pain | Pain reported by the patient according to Visual Analogic Scale | Fifteen hours after surgery |
| Fluid volumen drained (ml) | Fluid volume drained during procedure (ml) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jesús Montesinos, MD | Althaia Xarxa Assistencial de Manresa | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Althaia Xarxa Assistencial Universitària de Manresa | Manresa | Barcelona | 08243 | Spain |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Manual mobilization | Other | Manual mobilization using the Kaltenborn approach, in which 15 tibiofemoral glides were applied by a physiotherapist |
|
| Fifteen hours after surgery |
| Time (seconds) | Overall time spent in manual mobilization and CPM mobilization | Fifteen hours after surgery |