Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| LightIntegra Technology | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This is an observational study that evaluates the characteristics of Platelet Rich Plasma used in the therapy and treatment of musculoskeletal injuries and degenerative joint diseases.
A sample of the PRP will be tested for platelet and microparticle content using dynamic light scattering to determine if there is a relationship between the composition and the treatment outcome.
An observational study that evaluates the characteristics of Platelet Rich Plasma used in the therapy and treatment of musculoskeletal and degenerative joint conditions.
Patients enrolled in this study have already been assessed by the Principal Investigator and are schedule to receive treatment with Platelet Rich Plasma. Prior to the treatment patients will be asked to consent in the study where the composition of the PRP is to be evaluated. Consenting patients that meet inclusion/exclusion criteria will complete a pain score self-assessment prior to treatment.
An autologous preparation of PRP sample will be made from the subject's whole blood. The subject will receive the PRP treatment and an excess portion of the PRP preparation will be tested for composition and the relative concentration of the constituents.
The sample of the PRP will be tested using Dynamic Light Scattering (ThromboLUX System) to measure the constituents in PRP preparations prior to injection. PRP and whole blood (at physician's discretion) will be analyzed on a hematology analyzer.
The testing work-flow does not alter the subject's standard of care. The physician will be blinded to the analytical results during the enrolment, treatment and patient follow-up phase of the study. Analytical results are not used in patient management decisions.
Patient's response to the PRP treatment will be assessed at 3 and 6 weeks post injection. At these times, the clinical outcome of the treatment will be measured using a patient self -assessment (post-treatment pain scores).
This study will test the hypothesis that PRP characteristics, such as platelet and microparticle content and composition can be predictive clinical outcome for PRP treatments.
The clinical outcome will be evaluated by patient pre- and post-pain score assessment. This study aims to review clinical outcomes and compare these results against ThromboLUX and other test results. If the predictive value of platelet composition testing can be demonstrated, additional studies may be considered.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Change in pre- and post- pain score at 3 and 6 weeks | The primary objective of the study is to test the hypothesis that the constituents in platelet-rich plasma (PRP) preparations, such as platelet and microparticle content and composition, can be correlated to the clinical outcome for PRP treatments. | Up to 6 weeks after injection |
| The impact of microparticle content on pain scores | The study will ascertain the capability of ThromboLUX microparticle assay results to correlate with the clinical outcome for PRP treatments when evaluated by patient pre- and post-pain score assessment. | Up to 6 weeks after injection |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation of platelet count to ThromboLUX results | Evaluation of PRP platelet count to clinical outcome and ThromboLUX data outputs | Up to 6 weeks after injection |
| The use of dynamic light scattering (ThromboLUX) as a patient screening tool |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
The study population will consist of adults have been selected to receive platelet-rich plasma (PRP) injections as a treatment for musculoskeletal or degenerative joint conditions
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Don McKenzie, MD, PhD, LLD | University of British Columbia | Principal Investigator |
| Jennifer Leung, MSc | LightIntegra Technology Inc | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Allan McGavin Sports Medicine Centre | Vancouver | British Columbia | V6T1Z3 | Canada |
Not provided
Not provided
| ID | Type | URL | Comment |
|---|---|---|---|
| Patient Brochure | View IPD |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D059352 | Musculoskeletal Pain |
| D010003 | Osteoarthritis |
| D000377 | Agnosia |
| D007249 | Inflammation |
| ID | Term |
|---|---|
| D009135 | Muscular Diseases |
| D009140 | Musculoskeletal Diseases |
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
Not provided
Not provided
Not provided
Not provided
Not provided
To verify the performance of the ThromboLUX instrument in a clinical setting by reviewing size and composition of constituents in PRP
| Up to 6 weeks after injection |
| D012816 |
| Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D001168 | Arthritis |
| D007592 | Joint Diseases |
| D012216 | Rheumatic Diseases |
| D010468 | Perceptual Disorders |
| D019954 | Neurobehavioral Manifestations |
| D009422 | Nervous System Diseases |
| D010335 | Pathologic Processes |