Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| IRB00053627 | Other Identifier | JHMIRB | |
| R01CA161613 | U.S. NIH Grant/Contract | View source |
Not provided
Not provided
Not provided
Ultrasound vendor cannot support the study
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| National Cancer Institute (NCI) | NIH |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This research study is being done to collect data and analyze the motion of soft tissue in the abdomen (liver, pancreas, stomach and intestines) of people who have pancreatic and liver cancer as well as healthy volunteers.
During the study researchers will look at the movement of organs in the abdomen that naturally occurs with breathing and with a bowel movement.
This study will examine the differences between abdominal soft tissue motion in healthy volunteers and in cancer patients with the goal of developing a better way to manage and minimize the abdominal soft tissue motion. Accurate location of the tumor is very important in treatment delivery and reduction of toxicity.
Within the last decade, Linac based stereotactic body radiation therapy (SBRT) has been shown to be an effective treatment option for pancreas1, 2 and liver3, 4 tumors. SBRT delivers high doses of radiation therapy to the tumor over only 1-5 treatments. Because of the spatial precision of SBRT, it is feasible to administer a high radiation dose in only a few treatments. By minimizing the amount of radiation to surrounding healthy tissue, it is possible to decrease the rate of toxicity/complication and increase the radiation dose to cancerous tissue, thereby allowing better local control.
SBRT of the abdomen has been limited by the movement of intra-abdominal organs that naturally occurs with respiration and bowel movement. Organ motion occurs both intra- and inter-fractionally. While intra-fractional motion is a result of respiration, peristalsis and cardiac motion, the magnitude of inter-fractional target motion is dependent of daily variations in organ filling, weight change, tumor growth and radiation induced changes of tissue. Tumor movement may lead to tumor displacement and suboptimal dose delivery. Accurate localization of the target is very important to improve treatment delivery accuracy and reduce toxicity of the treatment. To evaluate tumor motion due to breathing motion, a four dimensional (4D) CT simulation scan is performed. If the tumor moves more than 3 mm during a breathing cycle, breathing motion management is employed using Active Breathing Control (ABC) technique. ABC requires the patient to hold his/her breath within the proper tidal volume while treatment is delivered, while free breathing may be resumed between periods of treatment. This technique limits the delivery of RT to specific phases of the respiratory cycle so as to minimize the influence of breathing on the delineated tumor.
Despite significant progress made in ABC technique, tumor and organ motion could only be minimized and not eliminated completely with this technique. Assessing patient specific tumor/organ motion (both intra- and interfractional) throughout the course of SBRT treatment offers the possibility of ensuring delivery of the prescribed target dose while simultaneously minimizing normal tissue damage. In order to monitor the abdominal soft tissue motion, the Department of Radiation Oncology has developed a 4D ultrasound technique based on an ultrasound probe holder and a continuous motion monitoring software. The 4D ultrasound image is acquired by using a motorized 3D ultrasound probe and image continuously. 4D ultrasound is a new non-ionizing and non-invasive imaging technique that continuously monitors the tumor motion during the radiation treatment in real time.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pancreatic Cancer | Active Comparator | A 4D ultrasound scan of the pancreas will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor pancreas motion. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. |
|
| Liver Cancer | Active Comparator | A 4D ultrasound scan of the liver will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor liver motion. The system will record all relevant images, but will not be used in clinical decision making. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. |
|
| Healthy Volunteer | Other |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ultrasound scan of the pancreas | Device | A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. |
| Measure | Description | Time Frame |
|---|---|---|
| Abdominal Soft-tissue Movement | Measuring changes in abdominal soft-tissue movement through 4D ultrasound system | change in abdominal soft-tissue movement from baseline to 3 weeks |
| Tissue Change During Radiation Treatment | monitoring of tumor and surrounding organ/tissue during pancreas and liver SBRT treatments using 4D ultrasound system | change in tumor tissue from baseline to 3 weeks |
| Change 4D Ultrasound to Traditional Cone-beam Computed Tomography (CBCT) Monitoring | Evaluate accuracy of the 4D ultrasound motion monitoring system compare to CBCT based intra-fraction motion monitoring during pancreas and liver SBRT treatments | change in imaging studies of 4D ultrasound from baseline to 3 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Dosimetry Measurements | Evaluation of dosimetry differences due to target/organ motion observed | dosimetric changes in abdominal soft-tissue movement from baseline to the end of radiation treatment at 3 weeks |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Amol Narang, M.D. | The SKCCC at Johns Hopkins | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Johns Hopkins Sidney Kimmel Comprehensive Cancer Center | Baltimore | Maryland | 21231 | United States |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Pancreatic Cancer | A 4D ultrasound scan of the pancreas will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor pancreas motion. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the pancreas: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. |
| FG001 | Liver Cancer | A 4D ultrasound scan of the liver will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor liver motion. The system will record all relevant images, but will not be used in clinical decision making. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the Liver: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. |
| FG002 | Healthy Volunteer | A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. Additional registration of ultrasound images will be performed with Velocity software to evaluate accuracy of automated registration software in the ultrasound system. Reference ultrasound: A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. |
| Title | Milestones | Reasons Not Completed | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
|
Sponsor closed study after 2 patients in Pancreatic Cancer arm of the study were enrolled.
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Pancreatic Cancer | A 4D ultrasound scan of the pancreas will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor pancreas motion. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the pancreas: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Abdominal Soft-tissue Movement | Measuring changes in abdominal soft-tissue movement through 4D ultrasound system | Patients were consented, enrolled and taken off study during the period 5/3/2016-6/9/2016. Data was not collected or analyzed because the sponsor closed the study early. In order to collect and analyze the data, treatment would have to have been completed. | Posted | change in abdominal soft-tissue movement from baseline to 3 weeks |
|
Not provided
Adverse events were not collected
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Pancreatic Cancer | A 4D ultrasound scan of the pancreas will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor pancreas motion. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the pancreas: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the pancreas motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup can be reproduced during treatment delivery. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Amol Narang | Johns Hopkins, East Baltimore | 410-913-3395 | anarang2@jhmi.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jul 18, 2016 | Nov 1, 2023 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D010190 | Pancreatic Neoplasms |
| D008113 | Liver Neoplasms |
| ID | Term |
|---|---|
| D004067 | Digestive System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D004701 | Endocrine Gland Neoplasms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. Additional registration of ultrasound images will be performed with Velocity software to evaluate accuracy of automated registration software in the ultrasound system. |
|
|
|
| Ultrasound scan of the Liver | Device | A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. |
|
|
| Reference ultrasound | Drug | A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. |
|
|
| BG001 | Liver Cancer | A 4D ultrasound scan of the liver will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor liver motion. The system will record all relevant images, but will not be used in clinical decision making. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the Liver: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. |
| BG002 | Healthy Volunteer | A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. Additional registration of ultrasound images will be performed with Velocity software to evaluate accuracy of automated registration software in the ultrasound system. Reference ultrasound: A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. |
| BG003 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| OG001 | Liver Cancer | A 4D ultrasound scan of the liver will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor liver motion. The system will record all relevant images, but will not be used in clinical decision making. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the Liver: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. |
| OG002 | Healthy Volunteer | A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. Additional registration of ultrasound images will be performed with Velocity software to evaluate accuracy of automated registration software in the ultrasound system. Reference ultrasound: A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. |
|
| Primary | Tissue Change During Radiation Treatment | monitoring of tumor and surrounding organ/tissue during pancreas and liver SBRT treatments using 4D ultrasound system | Patients were consented, enrolled and taken off study during the period 5/3/2016-6/9/2016. Data was not collected or analyzed because the sponsor closed the study early. In order to collect and analyze the data, treatment would have to have been completed. | Posted | change in tumor tissue from baseline to 3 weeks |
|
|
| Primary | Change 4D Ultrasound to Traditional Cone-beam Computed Tomography (CBCT) Monitoring | Evaluate accuracy of the 4D ultrasound motion monitoring system compare to CBCT based intra-fraction motion monitoring during pancreas and liver SBRT treatments | Patients were consented, enrolled and taken off study during the period 5/3/2016-6/9/2016. Data was not collected or analyzed because the sponsor closed the study early. In order to collect and analyze the data, treatment would have to have been completed. | Posted | change in imaging studies of 4D ultrasound from baseline to 3 weeks |
|
|
| Secondary | Change in Dosimetry Measurements | Evaluation of dosimetry differences due to target/organ motion observed | Patients were consented, enrolled and taken off study during the period 5/3/2016-6/9/2016. Data was not collected or analyzed because the sponsor closed the study early. In order to collect and analyze the data, treatment would have to have been completed. | Posted | dosimetric changes in abdominal soft-tissue movement from baseline to the end of radiation treatment at 3 weeks |
|
|
| 0 |
| 0 |
| 0 |
| 0 |
| 0 |
| 0 |
| EG001 | Liver Cancer | A 4D ultrasound scan of the liver will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. On each treatment day, 4D ultrasound images will be acquired continuously during beam on time to monitor liver motion. The system will record all relevant images, but will not be used in clinical decision making. Intra-fraction CBCT images acquired during treatment will be registered with reference CT images. Organ motion registered by ultrasound will be compared to motion recorded by CBCT and the accuracy of the ultrasound system will be evaluated. Ultrasound scan of the Liver: A 4D ultrasound scan will be acquired at the time at simulation and used as a reference ultrasound image for localizing tracking target. The ultrasound probe will be placed at the abdominal area to monitor the liver motion. The probe will remain in place during the CT scan. Patient setup and the ultrasound probe location will be recorded so that the same setup could be reproduced during treatment delivery. The ultrasound probe in the CT image will be contoured and radiation beams that directly pass through the ultrasound probe will be avoided. | 0 | 0 | 0 | 0 | 0 | 0 |
| EG002 | Healthy Volunteer | A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. Additional registration of ultrasound images will be performed with Velocity software to evaluate accuracy of automated registration software in the ultrasound system. Reference ultrasound: A reference ultrasound scan will be conducted on each subject during breath-hold. Subjects will be required to lie in supine position and engaged with ABC; an ultrasound probe will be placed at the abdomen area with minimal pressure applied. Continuous motion monitoring is achieved by acquiring 4D ultrasound images using a motorized 3D ultrasound probe to image the pancreas, liver and other intra-abdominal organs continuously. Several 4D ultrasound scans will be collected during subsequent breath-holds that serve as secondary images. | 0 | 0 | 0 | 0 | 0 | 0 |
Not provided
Not provided
| D004066 |
| Digestive System Diseases |
| D010182 | Pancreatic Diseases |
| D004700 | Endocrine System Diseases |
| D008107 | Liver Diseases |