The purpose of this clinical study is to evaluate the and performance of the Imricor Medical Systems, Inc. (Imricor) MR Ablation Catheter when used with related accessories for the treatment of type I atrial flutter. The Vision Ablation Catheter and its accessories have been designed for use under fluoroscopic or magnetic resonance guidance. The study will be a single center study conducted at the Leipzig University Hospital Heart Center in Germany. The study population will consist of adult patients requiring ablation for type I atrial flutter.
The study will be a single center study conducted at the Leipzig University Hospital Heart Center in Germany. 35 subjects including 5 roll-in subjects meeting inclusion/exclusion criteria will participate in the study. This study requires the use of investigational products from two independent manufacturers: Imricor and Philips. Imricor has developed the ablation catheter with related accessory cables and electrophysiology (EP) recorder/stimulator system. Philips has developed an image guidance and mapping system that is compatible with the Imricor products.
The Vision-MR Ablation Catheter will be used in conjunction with the following investigational products: Advantage-MR EP Recorder/Stimulator, Vision-MR Ablation Cable Set, Vision-MR Diagnostic Cable, the interventional MRI Suite (iSuite) image guidance and mapping system, and a dStream Interface (dSIF-FE). With the exception of iSuite and dSIF-FE, which are manufactured by Philips, Imricor will provide all investigational devices used in the study.
Each procedure will require two single-use Vision-MR Ablation Catheters and one each of the two single-use accessory catheter cables.
Ablation for the treatment of arrhythmia is an inherently complex procedure. Use of the investigational products listed above under MR guidance is an emerging approach to performing the interventional electrophysiology procedure.
The study population will consist of adult patients requiring ablation for type I atrial flutter.
Study subjects will require a follow-up visit or telephone call at seven days post procedure. Accordingly, the expected total study duration is approximately 9 months with study start planned for March 2016.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ablation for typical atrial flutter | Experimental | This group receives an MR-guide ablation for atrial flutter with the study device ( Vision-MR ablation catheter ) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ablation for typical atrial flutter | Procedure |
| ||
| Vision-MR ablation catheter |
| Measure | Description | Time Frame |
|---|---|---|
| Number of patients with bidirectional cavo-tricuspid isthmus block after intervention | Acute success defined as the demonstration of the established electrophysiological endpoint (e.g. bidirectional cavo-tricuspid isthmus block after radiofrequency application in the cavo-tricuspid isthmus) with the investigational device. Historically, the acute success rate for RF ablation of type I atrial flutter is 72%. Analysis will be based on a binomial proportion and expressed as a percentage. For a total of N subjects with S achieving success, the percentage, represented as P, will be calculated as P = 100*S/N. | 9 months |
| Incidence of Treatment-Emergent Serious Adverse Events [Safety]) | The primary safety endpoint is the rate of serious adverse events (SAEs) related to the device or procedure. Analysis will be based on a binomial proportion and expressed as a percentage. For a total of N subjects with S experiencing an SAE related to the device or procedure, the percentage, represented as P, will be calculated as P = 100*S/N. | 9 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gerhard Hindricks, MD | Heart Center Leipzig | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Heart Center Leipzig | Leipzig | 04289 | Germany |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26316146 | Background | Hilbert S, Sommer P, Gutberlet M, Gaspar T, Foldyna B, Piorkowski C, Weiss S, Lloyd T, Schnackenburg B, Krueger S, Fleiter C, Paetsch I, Jahnke C, Hindricks G, Grothoff M. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series. Europace. 2016 Apr;18(4):572-7. doi: 10.1093/europace/euv249. Epub 2015 Aug 27. |
| Label | URL |
|---|---|
| Imricor website | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001282 | Atrial Flutter |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
|
| D013568 |
| Pathological Conditions, Signs and Symptoms |