Comparison of the preoxygenation efficacy of tidal volume breathing using three different preoxygenation techniques which are available to providers in the prehospital environment.
Prospective randomised interventional study.
Healthy volunteers will be positioned supine and undergo preoxygenation by tidal volume breathing for 3 minutes using each technique in turn. The sequence of techniques for each volunteer will be randomised in advance. Investigators will be instructed to ensure a good mask seal throughout the testing period. At the end of a 3 minute preoxygenation period, after a brief breath hold, the volunteer will exhale into reservoir tubing, allowing the fractional expired oxygen concentration (FeO2) to be determined (primary outcome) using a calibrated gas analyser.
The techniques being assessed have been chosen from methods of preoxygenation commonly available to clinicians in the prehospital environment:
Volunteers will also be asked to indicate the subjective ease of breathing for each technique (secondary outcome) using a visual analogue scale (VAS).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| CPAP | Experimental | 3 minutes of preoxygenation with a portable ventilator providing Continuous Positive Airway Pressure (CPAP) at 5 cmH20 and an FiO2 of 100%. |
|
| BVM | Experimental | 3 minutes of preoxygenation with a bag-valve-mask (BVM) device and oxygen flow rate of 15 litres / minute. |
|
| NRM | Experimental | 3 minutes of preoxygenation with a non-rebreather mask (NRM) device and oxygen flow rate of 15 litres / minute. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Continuous Positive Airway Pressure (CPAP) | Device | CPAP provided by a portable Draeger Oxylog® 3000 plus ventilator |
|
| Measure | Description | Time Frame |
|---|---|---|
| Fractional Expired Oxygen Concentration | Measure of denitrogenation efficacy | 3 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Ease of breathing assessment using a visual analogue scale | Visual analogue scale to assess subjective ease of breathing through each device | 3 minutes |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Christopher J Groombridge, MBBS | Queen Mary University of London | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Essex & Herts Air Ambulance Trust | Earls Colne | Essex | CO6 2NS | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 26728311 | Background | Groombridge C, Chin CW, Hanrahan B, Holdgate A. Assessment of Common Preoxygenation Strategies Outside of the Operating Room Environment. Acad Emerg Med. 2016 Mar;23(3):342-6. doi: 10.1111/acem.12889. Epub 2016 Feb 17. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000860 | Hypoxia |
| ID | Term |
|---|---|
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D045422 | Continuous Positive Airway Pressure |
| ID | Term |
|---|---|
| D011175 | Positive-Pressure Respiration |
| D012121 | Respiration, Artificial |
| D058109 | Airway Management |
| D013812 | Therapeutics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Bag-Valve-Mask (BVM) | Device | Preoxygenation provided by BVM device, oxygen flow rate 15 l/min |
|
| Non-rebreather Mask (NRM) | Device | Preoxygenation provided by NRM, oxygen flow rate 15 l/min |
|