Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of the study is to compare Tip-Apex Distance values in two groups of patients after intramedullary nailing of proximal femur. The first group of patients is operated with the help of a 3D reconstruction device connected to the standard fluoroscopy allowing the surgeon to visualize directly the exact position of the tip of the trans-cervical screw while the second group (which is the reference-group) is operated with the help of fluoroscopy alone.
The main orthopedic complication after fixation of a proximal femoral fracture with a cephalo-medullary nail is the cut-out of the cephalic screw from femoral head resulting in a protrusion of this screw in the coxo-femoral joint, mostly during the first 6 months after the operation. In most cases, the surgeon has to remove the primary implant and perform a total hip arthroplasty to his patient, therefore rising the morbidity and social costs linked to the treatment of the initial fracture.
Baumgartner showed the importance of the position of the cephalic screw for predicting failure of the implant and proposed a new measurement to evaluate this position, the tip-apex distance which is the sum of the distance from the tip of the cephalic screw to the apex of the femoral head on an anteroposterior radiograph and this distance on a lateral radiograph, after controlling for magnification. He showed a lower TAD was associated with a lower risk of cut-out.
The aim of this study is to evaluate the help of a 3D reconstruction software linked to the standard fluoroscopy in achieving the lowest TAD and therefore minimizing the cut-out rate.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| FluoroMap group | Experimental | Adult patients with a proximal femoral fracture eligible for intramedullary nailing with a Gamma 3 nail (Stryker Inc). In this group, the surgeon will use the FluoroMap 3D reconstruction system (Stryker Inc) with the standard fluoroscopy to help him place the cephalic screw in the femoral head. |
|
| Test group | No Intervention | Adult patients with a proximal femoral fracture eligible for intramedullary nailing with a Gamma 3 nail (Stryker Inc). In this group, the surgeon will use only the standard fluoroscopy to help him visualize the position of the cephalic screw in the femoral head. |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| FluoroMap 3D | Device | Use of the 3D reconstruction software developed by the manufacturer of the Gamma Nail (e.g. Stryker Inc.) along with the standard fluoroscopy |
|
| Measure | Description | Time Frame |
|---|---|---|
| Tip-Apex distance | Change of the value of the tip-apex distance at each follow-up control (6 weeks, 3 and 6 months) compared to the post-op value | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Cut-out of the cephalic screw | Visualization of a migration of the tip of the cervical screw outside the femoral head on one radiological incidence will be considered as a "cut-out" and reported in the final results | 6 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hopital du Valais | Recruiting | Sion | Valais | 1951 | Switzerland |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D005264 | Femoral Fractures |
| D006620 | Hip Fractures |
| ID | Term |
|---|---|
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |
| D007869 | Leg Injuries |
| D025981 | Hip Injuries |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|