The purpose of this study was to evaluate whether CO2 rebreathing occurs in healthy subjects or patients with COPD ventilated during exercise assisted by the single-limb circuit with a plateau exhalation valve at a given inspiratory positive airway pressure and a minimal level of expiratory positive airway pressure (EPAP) and whether there is a potential threshold for predicting CO2 rebreathing.
Non-invasive ventilation circuit consists of single-limb tubing for inspiration and expiration, including a plateau exhalation valve. As exhaled gases was vented out the plateau exhalation valve at a constant rate, during exercise, with the increase of exhalation flow, single-limb circuit with a plateau exhalation valve might cause carbon dioxide(CO2) rebreathing. Therefore, our aim in the present study was to evaluate whether CO2 rebreathing occurs in COPD patients ventilated during exercise assisted by the single-limb circuit with a plateau exhalation valve and estimate a potential threshold for predicting CO2 rebreathing.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| COPD patients | Other | Oxygen was delivered to the face mask by a tube at a constant rate (5L/min) to keep the fingertip oxygen saturation at 90% or above. Ventilatory assistance was delivered using a BiPAP® Vision® ventilator (Respironics, Murrysville, Pennsylvania, USA) in BiPAP mode applied via a tightly fitting full face mask (Curative, Suzhou, China). A symptom-limited cycle exercise test was performed while assisted by non-invasive ventilation (NIV). All measurements were recorded at inspiratory pressure of 14 cmH2O, expiratory pressure of 4 cmH2O during rest and exercise. Breathing pattern, mean exhalation flow, mean plateau exhalation valve flow, the mean inspiratory fraction of CO2 (tidal FiCO2) reinsufflated from the circuit between the mask and the exhalation valve was measured for each breath. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| BiPAP® Vision® ventilator("Ventilator", "Philips Respironics™ BiPAP® Vision®" ) | Device | See details from arm descriptions. |
|
| Measure | Description | Time Frame |
|---|---|---|
| mean exhalation valve flow | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| Measure | Description | Time Frame |
|---|---|---|
| mean exhalation flow | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. | |
| mean inspiratory fraction of CO2 for each tidal volume |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Rongchang Chen, MD | Guangzhou Institute of Respiratory Disease | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| State Key Laboratory of Respiratory Disease, First Affiliated Hospital of Guangzhou Medical University | Guangzhou | Guangdong | 510120 | China |
Not provided
| ID | Term |
|---|---|
| D029424 | Pulmonary Disease, Chronic Obstructive |
| D009043 | Motor Activity |
| ID | Term |
|---|---|
| D008173 | Lung Diseases, Obstructive |
| D008171 | Lung Diseases |
| D012140 | Respiratory Tract Diseases |
| D002908 | Chronic Disease |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| fraction of end-tidal carbon dioxide partial pressure | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| inspiratory time | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| expiratory time | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| respiratory rate | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| inspiratory tidal volume | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| expiratory tidal volume | Measurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process. |
| D020969 |
| Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D001519 | Behavior |