The WITAVI study was designed to explore the kinetic and associated outcome of Von Willebrand Factor-multimerizaton defects associated with devices in cardiovascular diseases.
This study was designed to understand the Von Willebrand Factor (VWF) abnormalities observed in association with implantation of different devices in cardiovascular diseases (percutaneous valve replacement and circulatory support devices).
The main objective of the study was to describe the time-course of VWF abnormalities onset/offset during implantation of devices in cardiovascular diseases.
Adult patients > 18 years who need a CF-LVAD or trans-aortic valve implantation are included in this cohort; Blood samples are obtained just before procedures
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| cardiac devices | patients receiving mechanical circulatory support patients undergoing transaortic valve replacement |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| cardiac devices | Device | patients receiving mechanical circulatory support or undergoing trans aortic valve replacement |
|
| Measure | Description | Time Frame |
|---|---|---|
| Von Willebrand factor (VWF) multimer defects | VWF multimeric analysis is performed by electrophoresis. The results of HMW-multimers are expressed as the relative amount of the largest multimers (mer>15) of the sample compared with those of the normal pooled plasma (NPP standard human plasma Siemens healthcare diagnostics, Marburg, Germany, coefficient of variation=11%) present on each gel. 4-6 With this method the HMW-multimer ratio is defined as the HMW-multimers (>15-mer) in patient plasma sample divided by HMW-multimers in normal pool plasma, the HMW-multimer ratio of normal pooled plasma is 1 (by definition) and an HMW-multimer defect is defined as a reduced HMW-multimer-ratio (<1). | 180 minutes after device implantation |
| Measure | Description | Time Frame |
|---|---|---|
| platelet function analyser- ADP (PFA-ADP) closure time | The PFA test is initially performed with the Collagen/Epinepherine membrane. A normal Col/ADP closure time (<180 seconds) excludes the presence of a significant platelet function defect. | 5, 15,30, 60 minutes; day 1 , day 7 after device implantation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
patients receiving mechanical circulatory support or undergoing aortic valve replacement
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Sophie Susen, MD, PhD | University Hospital, Lille | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Lille University Hospital | Lille | 59037 | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25670067 | Background | Van Belle E, Rauch A, Vincentelli A, Jeanpierre E, Legendre P, Juthier F, Hurt C, Banfi C, Rousse N, Godier A, Caron C, Elkalioubie A, Corseaux D, Dupont A, Zawadzki C, Delhaye C, Mouquet F, Schurtz G, Deplanque D, Chinetti G, Staels B, Goudemand J, Jude B, Lenting PJ, Susen S. Von Willebrand factor as a biological sensor of blood flow to monitor percutaneous aortic valve interventions. Circ Res. 2015 Mar 27;116(7):1193-201. doi: 10.1161/CIRCRESAHA.116.305046. Epub 2015 Feb 10. | |
| 32172643 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| D001024 | Aortic Valve Stenosis |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D000082862 | Aortic Valve Disease |
| D006349 | Heart Valve Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D058409 | Cardiac Resynchronization Therapy Devices |
| ID | Term |
|---|---|
| D010138 | Pacemaker, Artificial |
| D004566 | Electrodes |
| D055615 | Electrical Equipment and Supplies |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
| Derived |
| Vincent F, Spillemaeker H, Kyheng M, Belin-Vincent C, Delhaye C, Pierache A, Denimal T, Verdier B, Debry N, Moussa M, Schurtz G, Porouchani S, Cosenza A, Juthier F, Pamart T, Richardson M, Coisne A, Hertault A, Sobocinski J, Modine T, Pontana F, Duhamel A, Labreuche J, Van Belle E. Ultrasound Guidance to Reduce Vascular and Bleeding Complications of Percutaneous Transfemoral Transcatheter Aortic Valve Replacement: A Propensity Score-Matched Comparison. J Am Heart Assoc. 2020 Mar 17;9(6):e014916. doi: 10.1161/JAHA.119.014916. Epub 2020 Mar 16. |
| 27464202 | Derived | Van Belle E, Rauch A, Vincent F, Robin E, Kibler M, Labreuche J, Jeanpierre E, Levade M, Hurt C, Rousse N, Dally JB, Debry N, Dallongeville J, Vincentelli A, Delhaye C, Auffray JL, Juthier F, Schurtz G, Lemesle G, Caspar T, Morel O, Dumonteil N, Duhamel A, Paris C, Dupont-Prado A, Legendre P, Mouquet F, Marchant B, Hermoire S, Corseaux D, Moussa K, Manchuelle A, Bauchart JJ, Loobuyck V, Caron C, Zawadzki C, Leroy F, Bodart JC, Staels B, Goudemand J, Lenting PJ, Susen S. Von Willebrand Factor Multimers during Transcatheter Aortic-Valve Replacement. N Engl J Med. 2016 Jul 28;375(4):335-44. doi: 10.1056/NEJMoa1505643. |
| D014694 |
| Ventricular Outflow Obstruction |