The purpose of this study is to determine safety, feasibility and efficacy (with respect to sensor- augmented pump therapy) of an Artificial Pancreas (AP) prototype in day and night closed-loop control in children and adolescents with type 1 diabetes.
The AP prototype is based on a Modular Model Predictive Control algorithm (MMPC) implemented on the Diabetes Assistant (DiAs) wearable platform.
The study will be divided in two parts: the first part will serve as a 3 days pilot study and will be conducted in a hotel/residence near the hospital.
The investigators will recruit 6/8 children (5-12 years) and/or 6/8 adolescents (12-18 years), with type 1 diabetes who have experience with insulin pump. DiAs will be used 72 continuous hours of day and night.
If part 1 will be successfully, after about 2-3 months, the study will move to the second part (the main part), that will consist in cross-over randomized study that will be conducted in a camp setting. The participants will be randomly assigned to the treatment arm (Artificial Pancreas) or to the control arm (sensor-augmented insulin pump). Then the same patient will be assigned to the other arm. Each treatment will be applied 3 consecutive days. During the first period (days 1-3) patients will do the same activites and will have the same diet as in the second period (day s 5-7).
The investigators will recruit 30/40 children (5-12 years) and/or 30/40 adolescents (12-18 years), affected by type 1 diabetes who have experience with insulin pump therapy.
The study has the permission of the Ethics Committee reference and the permission for "clinical investigation with devices not CE marked" by the Health Ministry.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| AP | Experimental | Experimental arm: A closed-loop control system (artificial pancreas) will be used during night and day for 72 hours (3 days) with the aim of automate insulin infusion by an insulin pump to control glucose level. AP is composed of a CGM device (Dexcom G4), an insulin pump (Accu Chek Spirit combo, Roche), and a model predictive control algorithm that is embedded in a smartphone and wirelessly linked to the CGM device and insulin pump. A remote monitoring will be ensured all the time the AP will be active and study team will be present in the camp. Patients will be randomly assigned to receive either 3 days of automated closed-loop insulin delivery (intervention) followed by 3 days of sensor -augmented pump therapy (control), or the inverted sequence |
|
| SAP | Active Comparator | Active Comparator: Sensor Augmented Pump (SAP teraphy : CGM + insulin pump) will be used for 72 hours during day and night (3 days). Patients will be randomly assigned to receive either 3 days of SAP (Control) followed by 3 days of automated closed-loop insulin delivery (intervention), or the inverted sequence |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| artificial pancreas | Device | Patients will be randomly assigned to receive either 3 days of automated closed-loop insulin delivery (intervention) followed by 3 days of sensor -augmented pump therapy (control), or the inverted sequence. |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of Time Spent With Blood Glucose < 3.9 mmol/L (or 70 mg/dl) | percentage of time spent in hypoglicemia (< 70 mg/dl or 3.9 mmol/L) both during day and night. All analyses will include a comparison of the results in Artificial Pancreas and SAP period | 3 days |
| Percentage of Time Spent in Target Range (70-180 mg/dl or 3.9-10.0 mmol/L) | percentage of time spent in target range (70-180 mg/dl or 3.9-10.0 mmol/L) both during day and night. All analyses will include a comparison of the results in Artificial pancraes and SAP period | 3 days |
| Measure | Description | Time Frame |
|---|---|---|
| Percentage of Time Artificial Pancreas is Active | percentage of time that the system worked without any technical problem | 3 days |
Not provided
Inclusion Criteria:
Clinical diagnosis of type 1 diabetes · The diagnosis of type 1 diabetes is based on the investigator's judgment
· C peptide levels and antibody determinations are not required
Daily insulin therapy for ≥ 12 months
Insulin pump therapy for ≥ 3 months
Age 6-18 years
A1C<10
Avoidance of acetaminophen-containing medications (i.e. Tachipirina, tachidol, tachiflu) while wearing the continuous glucose monitor.
Willingness to wear a continuous glucose sensor
Female subjects who are sexually active must be on acceptable method of contraception (e.g. oral contraceptive pill, diaphragm, IUD).
Exclusion Criteria:
Diabetic ketoacidosis in the past month
Hypoglycemic seizure or loss of consciousness in the past 3 months
History of seizure disorder (except for hypoglycemic seizure)
A1C>10
History of any heart disease including coronary artery disease, heart failure, or arrhythmias
Cystic fibrosis
Current use of oral glucocorticoids, beta-blockers or other medications, which in the judgment of the investigator would be a contraindication to participation in the study.
History of ongoing renal disease (other than microalbuminuria).
Subjects requiring intermediate or long-acting insulin (such as NPH, Detemir , Glargine or Degludec).
Subjects requiring other anti-diabetic medications other than insulin (oral or injectable).
Pregnancy - verbal denial of pregnancy obtained with telephone informed consent, pregnancy test performed at camp before study devices are assigned.
Sexually active females who do not practice acceptable contraceptive methods to prevent pregnancy.
Presence of a febrile illness within 24 hours of admission or acetaminophen use while wearing the CGM. The subject may be rescheduled for Research House/hotel admission if these criteria are not met. The camp study subject will not participate in the trial if these conditions are met.
Medical or psychiatric condition that in the judgment of the investigator might interfere with the completion of the protocol such as:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Daniela Bruttomesso, MD | University of Padova, Italy | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Padova | Padova | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27208335 | Derived | Del Favero S, Boscari F, Messori M, Rabbone I, Bonfanti R, Sabbion A, Iafusco D, Schiaffini R, Visentin R, Calore R, Moncada YL, Galasso S, Galderisi A, Vallone V, Di Palma F, Losiouk E, Lanzola G, Tinti D, Rigamonti A, Marigliano M, Zanfardino A, Rapini N, Avogaro A, Chernavvsky D, Magni L, Cobelli C, Bruttomesso D. Randomized Summer Camp Crossover Trial in 5- to 9-Year-Old Children: Outpatient Wearable Artificial Pancreas Is Feasible and Safe. Diabetes Care. 2016 Jul;39(7):1180-5. doi: 10.2337/dc15-2815. Epub 2016 May 10. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Open Loop Than Closed Loop | Patients used for 3 days subcutaneous delivery of insulin according to usual pump regimen (open loop), than artificial pancreas for 3 days |
| FG001 | Closed Loop Than Open Loop | Patients used for 3 days artificial pancreas, than subcutaneous delivery of insulin according to usual pump regimen (open loop) for 3 days |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | All Study Participants | Experimental arm: A closed-loop control system (artificial pancreas) will be used during night and day for 72 hours (3 days) with the aim of automate insulin infusion by an insulin pump to control glucose level. AP is composed of a CGM device (Dexcom G4), an insulin pump (Accu Chek Spirit combo, Roche), and a model predictive control algorithm that is embedded in a smartphone and wirelessly linked to the CGM device and insulin pump. A remote monitoring will be ensured all the time the AP will be active and study team will be present in the camp. artificial pancreas: Patients will be randomly assigned to receive either 3 days of automated closed-loop insulin delivery (intervention) followed by 3 days of sensor -augmented pump therapy (control), or the inverted sequence. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Percentage of Time Spent With Blood Glucose < 3.9 mmol/L (or 70 mg/dl) | percentage of time spent in hypoglicemia (< 70 mg/dl or 3.9 mmol/L) both during day and night. All analyses will include a comparison of the results in Artificial Pancreas and SAP period | Posted | Mean | Inter-Quartile Range | percentage | 3 days |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | CLOSED LOOP | Experimental arm: A closed-loop control system (artificial pancreas) will be used during night and day for 72 hours (3 days) with the aim of automate insulin infusion by an insulin pump to control glucose level. AP is composed of a CGM device (Dexcom G4), an insulin pump (Accu Chek Spirit combo, Roche), and a model predictive control algorithm that is embedded in a smartphone and wirelessly linked to the CGM device and insulin pump. A remote monitoring will be ensured all the time the AP will be active and study team will be present in the camp. artificial pancreas: Patients will be randomly assigned to receive either 3 days of automated closed-loop insulin delivery (intervention) followed by 3 days of sensor -augmented pump therapy (control), or the inverted sequence. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Daniela Bruttomesso | Università di Padova-Italy | 00390498212183 | daniela.bruttomesso@unipd.it |
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D019397 | Pancreas, Artificial |
| ID | Term |
|---|---|
| D001187 | Artificial Organs |
| D013523 | Surgical Equipment |
| D004864 | Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| sensor augmented pump | Other | During this control period (comparator arm) the patients will use sensor augmented pump. This period will be compared to the same period of artificial pancreas |
|
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Race (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| OG001 | OPEN LOOP | Active Comparator: SAP teraphy (CGM + insulin pump) will be used for 72 hours during day and night (3 days). sensor augmented pump: During this control period (comparator arm) the patients will use sensor augmented pump. This period will be compared to the same period of artificial pancreas |
|
|
| Primary | Percentage of Time Spent in Target Range (70-180 mg/dl or 3.9-10.0 mmol/L) | percentage of time spent in target range (70-180 mg/dl or 3.9-10.0 mmol/L) both during day and night. All analyses will include a comparison of the results in Artificial pancraes and SAP period | Posted | Mean | Standard Deviation | percentage | 3 days |
|
|
|
| Secondary | Percentage of Time Artificial Pancreas is Active | percentage of time that the system worked without any technical problem | Posted | Mean | Inter-Quartile Range | percentage of time | 3 days |
|
|
|
| 0 |
| 32 |
| 0 |
| 32 |
| EG001 | OPEN LOOP | Active Comparator: SAP teraphy (CGM + insulin pump) will be used for 72 hours during day and night (3 days). sensor augmented pump: During this control period (comparator arm) the patients will use sensor augmented pump. This period will be compared to the same period of artificial pancreas | 0 | 32 | 0 | 32 |
Not provided
Not provided
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |