This is a pilot prospective cohort study of the incidence of supraglottic pH readings.
Aspiration is a serious morbidity that leads to an increase in both patient mortality and duration of hospital stays. Many practices exist within the hospital setting whose goal is to help prevent clinically significant aspiration including preoperative starvation, pharmaceutically reducing gastric acidity, facilitating gastric drainage, postural changes, cricoid pressure, endotracheal cuff pressure modification, and maintenance of a competent lower esophageal sphincter. However, to date, no monitoring system exists to help a clinician identify active aspiration. At present, video fluoroscopy, is the gold standard for detecting aspiration. This pilot prospective cohort study will examine the incidence of supraglottic pH readings.
A continuous pH/impedence sensor will be placed immediately above the glottic opening in four high risk populations: burn patients who are intubated, intubated post-stroke patients, patients undergoing robotic prostectomy, and in patients undergoing peritoneal tumor debulking and chemotherapy. The presence of acidic fluid above the glottic opening will be measured using a supraglottic impendence/pH probe attached to an endotracheal tube.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| supraglottic impendence/pH probe | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| pH monitoring | Other | After endotracheal intubation, the impedence/pH probe will be placed under indirect visualization using a McGrath MAC video laryngoscope directly above the vocal cords. The sensor will remain in place for the duration of the surgery or for 24 hours in ICU patients. At that time, the device will be manually removed by a member of the study staff. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of times pH drops below 5.5. | 24 hours period after placement of pH probe |
| Measure | Description | Time Frame |
|---|---|---|
| The mean of the angle (degrees) of the patient from the lateral position during low pH periods | 24 hours period after placement of pH probe |
| Measure | Description | Time Frame |
|---|---|---|
| Number of minutes the pH is less than 5.5 in a 24 hour | 24 hours period after placement of pH probe |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Brett Alvis, MD | Vanderbilt University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Vanderbilt University Medical Center | Nashville | Tennessee | 37212 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 11473886 | Background | Ng A, Smith G. Gastroesophageal reflux and aspiration of gastric contents in anesthetic practice. Anesth Analg. 2001 Aug;93(2):494-513. doi: 10.1097/00000539-200108000-00050. | |
| 16364934 | Background | Clayton J, Jack CI, Ryall C, Tran J, Hilal E, Gosney M. Tracheal pH monitoring and aspiration in acute stroke. Age Ageing. 2006 Jan;35(1):47-53. doi: 10.1093/ageing/afj007. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| accelerometer monitoring | Other | Patient position will be continuously monitored with the accelerometer for the duration of the pH monitoring period. |
|
| ID | Term |
|---|---|
| D053120 | Respiratory Aspiration |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided