The purpose of this study is to determine whether the Ambu KingVision videolaryngoscope performs as well as direct laryngoscopy for intubating small children and infants.
The goal of this prospective randomized study is to compare the Ambu KingVision Video Laryngoscope and direct laryngoscopy using the Miller Blade Laryngoscope.
The primary outcome of the study will be time to successful intubation. Other outcomes of clinical relevance such as first attempt success rates of intubation, grade of laryngeal view, percentage of glottic opening, number of insertion attempts, hemodynamic responses, and complications will also be assessed.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Direct Laryngoscopy | Active Comparator | The trachea will be intubated via direct laryngoscopy using a traditional straight blade (Miller) laryngoscope. |
|
| KingVision Video Laryngoscope | Experimental | The trachea will be intubated using the Ambu KingVision Video Laryngoscope size 1 pediatric blade. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ambu KingVision Video Laryngoscope aBlade | Device | At time of tracheal intubation, the subject will be intubated using the Ambu KingVision Video Laryngoscope with a size 1 aBlade. The first attempt to successful intubation will be assessed. The Cormack Lehane and Percentage of Glottic Opening scores will be recorded. Information on time to glottic view, time to removal of the blade, and time of first capnography upstroke (successful intubation) will be recorded. Other parameters measured will be information on subsequent attempts, ease of tracheal tube insertion, and hemodynamic responses for 5 minutes. |
| Measure | Description | Time Frame |
|---|---|---|
| Time to Intubation | Three timepoints will be recorded, beginning with insertion of the device past the lips into the mouth. These will include time to optimal glottic view, time to removal of device from mouth, and time to first CO2 capnography upstroke. The primary outcome measure will be total time to intubation, as the sum of all three timepoints. | Assessed intraoperatively at time of intubation |
| Measure | Description | Time Frame |
|---|---|---|
| First Attempt Success Rate of Tracheal Intubation | An attempt at tracheal intubation will be defined as entry of the device into the patient's mouth without the need to remove the device once entered and securing the airway. | Assessed intraoperatively at time of intubation |
| Grades of Laryngeal View |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Narasimhan Jagannathan, MD | Ann & Robert Lurie Children's Hospital of Chicago | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Ann & Robert H Lurie Children's Hospital of Chicago | Chicago | Illinois | 60611 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 20674088 | Background | Levitan RM, Heitz JW, Sweeney M, Cooper RM. The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices. Ann Emerg Med. 2011 Mar;57(3):240-7. doi: 10.1016/j.annemergmed.2010.05.035. Epub 2010 Jul 31. | |
| 23556410 | Background | Theiler L, Hermann K, Schoettker P, Savoldelli G, Urwyler N, Kleine-Brueggeney M, Arheart KL, Greif R. SWIVIT--Swiss video-intubation trial evaluating video-laryngoscopes in a simulated difficult airway scenario: study protocol for a multicenter prospective randomized controlled trial in Switzerland. Trials. 2013 Apr 4;14:94. doi: 10.1186/1745-6215-14-94. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Miller Direct Laryngoscopy | Device | At time of tracheal intubation, the subject will be intubated using a Miller blade laryngoscope. The first attempt to successful intubation will be assessed. The Cormack Lehane and Percentage of Glottic Opening scores will be recorded. Information on time to glottic view, time to removal of the blade, and time of first capnography upstroke (successful intubation) will be recorded. Other parameters measured will be information on subsequent attempts, ease of tracheal tube insertion, and hemodynamic responses for 5 minutes. |
|
Cormack Lehane (1-4) and percentage of glottic opening (POGO) (%) will be recorded after insertion of the laryngoscope |
| Assessed intraoperatively at time of intubation |
| Intubation Adjustments & Ease of Use | Airway manipulations utilized and ease of use (Likert 1-5) will be assessed by the user following the intubation. | Assessed intraoperatively following intubation |
| Hemodynamic Parameters - Heart Rate | Heart rate (beats per minute) will be assessed prior to intubation and at 1 minute intervals, for 5 minutes, following intubation. | Assessed intraoperatively at time of and following intubation |
| Hemodynamic Parameters - Blood Pressure | Blood pressure (mmHg) will be assessed prior to intubation and at 1 minute intervals, for 5 minutes, following intubation. | Assessed intraoperatively at time of and following intubation |
| Intraoperative Complications | Airway/device related complications including, laryngospasm, bronchospasm, oxygen desaturation, will be assessed at intubation, during the surgery, and after extubation while under the anesthesiologists care. | Assessed intraoperatively |
| Postoperative Complications | Airway/device related complications including sore throat, hoarseness, persistent coughing, stridor, and others will be assessed in the post anesthesia care unit. | Assessed postoperatively while admitted to the phase 1 recovery unit, approximately 30-60 minutes after surgery |
| 24742495 | Background | Murphy LD, Kovacs GJ, Reardon PM, Law JA. Comparison of the king vision video laryngoscope with the macintosh laryngoscope. J Emerg Med. 2014 Aug;47(2):239-46. doi: 10.1016/j.jemermed.2014.02.008. Epub 2014 Apr 16. |
| 23812581 | Background | Akihisa Y, Maruyama K, Koyama Y, Yamada R, Ogura A, Andoh T. Comparison of intubation performance between the King Vision and Macintosh laryngoscopes in novice personnel: a randomized, crossover manikin study. J Anesth. 2014 Feb;28(1):51-7. doi: 10.1007/s00540-013-1666-9. Epub 2013 Jun 30. |
| 28549081 | Derived | Jagannathan N, Hajduk J, Sohn L, Huang A, Sawardekar A, Albers B, Bienia S, De Oliveira GS. Randomized equivalence trial of the King Vision aBlade videolaryngoscope with the Miller direct laryngoscope for routine tracheal intubation in children <2 yr of age. Br J Anaesth. 2017 Jun 1;118(6):932-937. doi: 10.1093/bja/aex073. |