Thermodilution cardiac output measurement is a reliable method, but it is an invasive one. PiCCO device requires cannulation of central vein and peripheral artery. Impedance method requires only attachment of special electrodes. Non-invasive methods are less accurate. Aim of study is to assess accuracy and reliability of impedance method ( using NICCOMO device) in comparison of thermodilution method ( using PiCCO device) at different PEEP levels.
Echocardiography is performed prior to measurement to exclude patients with heart valve abnormalities.
Patients without spontaneous ventilation ( deeply unconscious, sedated or sedated and paralysed), ventilated with controlled mechanical ventilation mode with tidal volume 6-8 ml/ideal body weight, resulting in EtCO2 35-45 mmHg, with PiCCO catheters implemented have additionally NICCOMO device attached. Fraction of inspired oxygen (FiO2) is set to achieve saturation >96% at positive end expiratory pressure (PEEP) 0 cmH2O.
Measurement of cardiac output are performed on expiration at PEEP 0, 5, 10, 15 20 cmH2O and at optimal PEEP (obtained from P-V curve). Simultaneously CO value from impedance device is noted. Other haemodynamic parameters, calculated by both devices are also noted - stroke volume (SV), stroke volume variation (SVV), Cardiac index (CI), systemic vascular resistance (SVR), systemic vascular resistance index (SVRI).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| haemodynamics measuring | those with already implemented PICCO device get impedance device (NICCOMO) attached |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PICCO | Device | measurements based on thermodilution |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Numbers of measurements of haemodynamic parameters (CO, CI, SV, SVV, CI, SVR, SVRI) obtained with impedance, that differ from those obtained with thermodilution | measurements taken with impedance and thermodilution simultaneously, at PEEP 0, 5, 10, 15, 20 and at optimal PEEP | up to 90 minutes |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
patients treated in intensive therapy unit, mechanically ventilated, haemodynamics monitored with PiCCO technique
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Magdalena A Wujtewicz | Contact | +48583493357 | magwuj@gumed.edu.pl | |
| Radoslaw Owczuk | Contact | 605408140 | r.owczuk@gumed.edu.pl |
| Name | Affiliation | Role |
|---|---|---|
| Magdalena Wujtewicz | Department of Ophthalmology, Medical University of GdaĆsk | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Gdansk | Recruiting | Gdansk | 80-214 | Poland |
Not provided
Not provided
Not provided
Not provided
| NICCOMO |
| Device |