FDA/IRB approved but hospital administration vetoed the study fearing litigation of a preterm birth though the electrical uterine pacemaker/EI is not the cause.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
An electrical-inhibition (EI) uterine pacemaker device similar to an electrical heart pacemaker delivers a weak electrical current to the human uterus during active preterm labor to rapidly and safely inhibit the unwanted premature uterine contractions and possibly a preterm birth.
Electrical intervention (EI) uses bipolar, constant-current (1-20 mA), square-wave pulses in 20% duty cycles. Women in active preterm labor have an electrode catheter placed into the posterior fornix of the vaginal canal. The EI current is given up to 80 minutes while monitoring tocodynamometric (toco) contractions and adjunct electrohysterographic (EHG) activity while continuously monitoring maternal vital signs, fetal heart rate and electrocardiogram (fECG). The study includes a pre-EI control period (C1); the EI period, when a 10-second current burst is delivered only during a contraction; and a post-EI control period (C2). The whole study will take a maximum of two hours.
The uterine toco contraction frequency and adjunct EHG electrical activity are analyzed for changes caused by EI. Changes in maternal vital signs, fetal heart rate and fECG will determine EI side-effects.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Electrical Inhibition (EI) intervention | Experimental | Electrical Inhibition (EI) uterine pacemaker is activated only when there is a preterm uterine contraction. The EI uterine pacemaker delivers a 1-15mA (20mA maximum) constant direct current for only 2 seconds only while there is a preterm uterine contraction. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Electrical Inhibition (EI) | Device | constant direct current 1-20mA transvaginal 10 second bursts only when needed |
|
| Measure | Description | Time Frame |
|---|---|---|
| Decrease tocodynamometric monitored preterm uterine contraction frequency | Measure changes in preterm uterine mechanical contraction frequency as assessed by the tocodynamometer. This will be done for the duration of the study. | 30 seconds |
| Measure | Description | Time Frame |
|---|---|---|
| Decrease adjunct electrohysterographic monitored preterm uterine contraction electrical activity. | Measure changes in preterm uterine electrical contraction activity as assessed by the electrohysterogram. This will be done for the duration of the study. | 20 seconds |
Not provided
Inclusion Criteria:
between 24 to 34 weeks pregnant with a singleton gestation;
in preterm labor as defined by the American College of Obstetricians and Gynecologists and the American Academy of Pediatrics,78 as follows:
persistent uterine contractions (4 every 20 minutes or 8 every 60 minutes)
And any one or more of the following:
anticipate a normal spontaneous vaginal delivery (NSVD).
at least 18 years of age
signed a written Informed Consent Document
willing and able to comply with study requirements
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Jeffrey Karsdon, M.D. | New York University Hospital | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| New York University Hospital | Manhattan | New York | 10016 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16325601 | Result | Karsdon J, Garfield RE, Shi SQ, Maner W, Saade G. Electrical inhibition of preterm birth: inhibition of uterine contractility in the rabbit and pup births in the rat. Am J Obstet Gynecol. 2005 Dec;193(6):1986-93. doi: 10.1016/j.ajog.2005.05.009. | |
| 23089601 | Result | Karsdon J, El Daouk M, Huang WM, Ashmead GG. Electrical pacemaker as a safe and feasible method for decreasing the uterine contractions of human preterm labor. J Perinat Med. 2012 Nov;40(6):697-700. doi: 10.1515/jpm-2012-0136. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D047928 | Premature Birth |
| D007752 | Obstetric Labor, Premature |
| ID | Term |
|---|---|
| D007744 | Obstetric Labor Complications |
| D011248 | Pregnancy Complications |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided