The purpose of this study is to evaluate the safety and short-term effectiveness of implantation of Transcatheter Pulmonary Valve (TPV) for the treatment of congenital heart disease with pulmonary valve disease.
Diverse congenital heart diseases involving the pulmonary artery, such as Tetralogy of Fallot (TOF) with or without pulmonary atresia, or transposition of the great arteries with pulmonary stenosis, require implantation of an artificial conduit between the right ventricle and the pulmonary artery(PA). Because these conduits finally degenerate and result in pulmonary regurgitation and/or stenosis and progressive right ventricle (RV) dilation and eventual failure, patients need repetitive surgery for conduit revision. Transcatheter pulmonary valve implantation (TPVI) is a less invasive alternative to surgery in patients with dysfunctional right ventricular outflow tract (RVOT). TPV is a large-diameter (up to 28 mm) self-expandable stent with a relatively low profile from a nitinol wire backbone with valve leaflets made from porcine pericardial tissue. The TPV is indicated for use in patients with previous undergone replacement of bioprosthetic valve or conduit due to either pulmonary valve atresia, stenosis, regurgitation or a combination of them and present with dysfunctional RVOT requiring treatment for severe pulmonary regurgitation and/or RVOT conduit obstruction. Consecutive subject data should be collected at discharge, 1, 3, 6 month, and 1-5 years post TPV implantation.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Transcatheter Pulmonary Valve | Experimental | Transcatheter Pulmonary Valve (TaeWoong Medical Co., Ltd. Korea) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Transcatheter Pulmonary Valve (TPV) | Device | Transcatheter Pulmonary Valve Replacement |
|
| Measure | Description | Time Frame |
|---|---|---|
| Procedural success | Procedural success is defined as the TPV implant within desired position, RV-PA peak systolic pressure gradient <35mmHg by catheter, less mild pulmonary regurgitation by angiography, and freedom from explantation of the TPV at 24 hours post-implant. | 5day |
| Hemodynamic functional improvement at 6month | Hemodynamic functional improvement is defined as mean RVOT gradient ≤30 mmHg by continuous wave doppler, and a pulmonary regurgitant fraction <20% by cardiac magnetic resonance (MR). | 6 month |
| Procedural / Device related serious adverse events at 6month | 6 month |
| Measure | Description | Time Frame |
|---|---|---|
| Hemodynamic function | Hemodynamic function will be measured including peak RVOT pressure gradient, mean RVOT pressure gradient, RV-PA pressure gradient, RV pressure, cardiac output, cardiac index, RV end-diastolic volume by echocardiography, cardiac MR, or catheterization. | 5 year |
| Severity of pulmonary regurgitation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gi Beom Kim, PhD. MD | Seoul National University Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Seoul National University Hospital | Seoul | Haehak-ro Jongno-gu | 03080 | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29871940 | Derived | Kim GB, Song MK, Bae EJ, Park EA, Lee W, Lim HG, Kim YJ. Successful Feasibility Human Trial of a New Self-Expandable Percutaneous Pulmonary Valve (Pulsta Valve) Implantation Using Knitted Nitinol Wire Backbone and Trileaflet alpha-Gal-Free Porcine Pericardial Valve in the Native Right Ventricular Outflow Tract. Circ Cardiovasc Interv. 2018 Jun;11(6):e006494. doi: 10.1161/CIRCINTERVENTIONS.118.006494. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 5year |
| Pulmonary regurgitant fraction | 5year |
| New York Heart Association (NYHA) functional classification | 5 year |
| Stent fracture | 5 year |
| Catheter reintervention on TPV | 5 year |
| Reoperation | 5 year |
| Procedural / Device related serious adverse events | 5 year |
| Death (all cause / procedural / device-related) | 5 year |
| Other adverse events | 5 year |
| ID | Term |
|---|---|
| D006330 | Heart Defects, Congenital |
| D018376 | Cardiovascular Abnormalities |
| D011665 | Pulmonary Valve Insufficiency |
| D011666 | Pulmonary Valve Stenosis |
| ID | Term |
|---|---|
| D002318 | Cardiovascular Diseases |
| D006331 | Heart Diseases |
| D000013 | Congenital Abnormalities |
| D009358 | Congenital, Hereditary, and Neonatal Diseases and Abnormalities |
| D006349 | Heart Valve Diseases |
| D014694 | Ventricular Outflow Obstruction |
Not provided