The main objective of the SeQuent® Please Neo post market surveillance is to assess the clinical suitability of the combination of pre-dilatation using the NSE Alpha scoring balloon before the use of the paclitaxel-coated SeQuent® Please Neo in an 'all comer'/ 'real world' setting for the treatment of in-stent restenosis and de-novo lesions.
The aim of this post market surveillance is to document the safety and efficacy of the drug-coated balloon Sequent® Please Neo in combination with the NSE Alpha scoring balloon in the treatment of both in-stent restenosis and de-novo lesions in native coronary arteries with reference diameters of 2.5 mm up to 4.0 mm with lesion lengths of 30 mm for procedural success and preservation of vessel patency
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Drug Coated Balloon Angioplasty, Scoring Balloon Dilatation | Device | Percutaneous Coronary Intervention |
|
| Measure | Description | Time Frame |
|---|---|---|
| Target Vessel Failure | Target Vessel Failure = TLR + Myocardial Infarction (MI) + cardiac death | 9 months |
| Measure | Description | Time Frame |
|---|---|---|
| procedural success rate | lesion crossing success in in-stent restenotic lesions | intraprocedural |
| Target Lesion Revascularization rate = Re-PCI + CABG(TLR) | 9 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients with coronary artery disease, specifically with in-stent restenosis
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Klaus Bonaventura, MD | Klinikum Ernst von Bergmann | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Klinikum Ernst von Bergmann | Potsdam | 14467 | Germany |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23040575 | Background | Wohrle J, Zadura M, Mobius-Winkler S, Leschke M, Opitz C, Ahmed W, Barragan P, Simon JP, Cassel G, Scheller B. SeQuentPlease World Wide Registry: clinical results of SeQuent please paclitaxel-coated balloon angioplasty in a large-scale, prospective registry study. J Am Coll Cardiol. 2012 Oct 30;60(18):1733-8. doi: 10.1016/j.jacc.2012.07.040. Epub 2012 Oct 3. | |
| 21624553 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| cardiac death | death of cardiac or unknown causes | 9 months |
| Rate of coronary arterial bypass grafting (CABG) | 9 months |
| rate of myocardial infarction | 9 months |
| Almalla M, Schroder JW, Pross V, Stegemann E, Marx N, Hoffmann R. Everolimus-eluting versus paclitaxel-eluting stents for treatment of bare metal stent restenosis. Am J Cardiol. 2011 Aug 15;108(4):518-22. doi: 10.1016/j.amjcard.2011.03.080. Epub 2011 May 31. |
| 26003022 | Result | Kufner S, Cassese S, Valeskini M, Neumann FJ, Schulz-Schupke S, Hoppmann P, Fusaro M, Schunkert H, Laugwitz KL, Kastrati A, Byrne RA; ISAR-DESIRE 3 Investigators. Long-Term Efficacy and Safety of Paclitaxel-Eluting Balloon for the Treatment of Drug-Eluting Stent Restenosis: 3-Year Results of a Randomized Controlled Trial. JACC Cardiovasc Interv. 2015 Jun;8(7):877-84. doi: 10.1016/j.jcin.2015.01.031. Epub 2015 May 20. |
| 22386286 | Result | Rittger H, Brachmann J, Sinha AM, Waliszewski M, Ohlow M, Brugger A, Thiele H, Birkemeyer R, Kurowski V, Breithardt OA, Schmidt M, Zimmermann S, Lonke S, von Cranach M, Nguyen TV, Daniel WG, Wohrle J. A randomized, multicenter, single-blinded trial comparing paclitaxel-coated balloon angioplasty with plain balloon angioplasty in drug-eluting stent restenosis: the PEPCAD-DES study. J Am Coll Cardiol. 2012 Apr 10;59(15):1377-82. doi: 10.1016/j.jacc.2012.01.015. Epub 2012 Feb 29. |
| 23206837 | Result | Byrne RA, Neumann FJ, Mehilli J, Pinieck S, Wolff B, Tiroch K, Schulz S, Fusaro M, Ott I, Ibrahim T, Hausleiter J, Valina C, Pache J, Laugwitz KL, Massberg S, Kastrati A; ISAR-DESIRE 3 investigators. Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial. Lancet. 2013 Feb 9;381(9865):461-7. doi: 10.1016/S0140-6736(12)61964-3. Epub 2012 Dec 1. |
| 24556098 | Result | Xu B, Gao R, Wang J, Yang Y, Chen S, Liu B, Chen F, Li Z, Han Y, Fu G, Zhao Y, Ge J; PEPCAD China ISR Trial Investigators. A prospective, multicenter, randomized trial of paclitaxel-coated balloon versus paclitaxel-eluting stent for the treatment of drug-eluting stent in-stent restenosis: results from the PEPCAD China ISR trial. JACC Cardiovasc Interv. 2014 Feb;7(2):204-211. doi: 10.1016/j.jcin.2013.08.011. |
| 32274746 | Derived | Bonaventura K, Schwefer M, Yusof AKM, Waliszewski M, Krackhardt F, Steen P, Ocaranza R, Zuhdi AS, Bang LH, Graf K, Bock U, Chin K. Systematic Scoring Balloon Lesion Preparation for Drug-Coated Balloon Angioplasty in Clinical Routine: Results of the PASSWORD Observational Study. Adv Ther. 2020 May;37(5):2210-2223. doi: 10.1007/s12325-020-01320-2. Epub 2020 Apr 9. |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |