| Name | Class |
|---|---|
| RenJi Hospital | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The main goal to treat early NLUTS is to relieve lower urinary tract syndrome and prevent from late complications. The present study is to evaluate the efficacy of electrical pudendal nerve stimulation (EPNS) and transanal/transvaginal electrical stimulation (TES) in NLUTD.The study design consists of a non-randomized, parallel controlled trial. A total of 60 eligible patients will be involved and divided into EPNS or TES group according to their location of medical treatment. The primary endpoint is lower urinary tract syndromes (ICIQ-FLUTS/MLUTS). The second endpoint is assessment of daily life Qol (ICIQ-LUTSqol), and residual urine volume.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Electrical pudendal nerve stimulation | Experimental | Electrical pudendal nerve stimulation At a frequency of 2.0 Hz and a moderate intensity (25~35 mA); 60 minutes three times a week for a total of four weeks |
|
| Transvaginal electrical stimulation | Active Comparator | At a current intensity of < 60 mA (as high as possible to get a contraction) and frequencies of 15 Hz and 85 Hz (alternate 3-min periods of stimulation); 30 min three times a week for a total of four weeks. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Electrical pudendal nerve stimulation | Device | Four sacral points are selected. The two upper points are located about 1 cm bilateral to the sacrococcygeal joint. Needles of 0.40 Х 100 mm are inserted perpendicularly to the upper points to a depth of 80 to 90 mm to produce a sensation referred to the urethra or the anus. The two lower points are about 1 cm bilateral to the tip of the coccyx. Needles of 0.40 Х 100 or 125 mm are inserted obliquely to the lower points towards the ischiorectal fossa to a depth of 90 to 110 mm to produce a sensation referred to the urethra. After the sensation referred to the above regions is produced, each of two pairs of electrodes from a G6805-2 Multi-Purpose Health Device is connected with the two ipsilaterally needles. |
| Measure | Description | Time Frame |
|---|---|---|
| A questionaire to measure the severity of lower urinary tract symptoms (male/female) | 1.5 years |
| Measure | Description | Time Frame |
|---|---|---|
| A questionaire to evaluate the Qol | 1.5 years | |
| Residual urine volume | 1.5 years |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Siyou Wang, Master | Shanghai research institute of acupuncture and meridian | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Shanghai research institute of acupuncture and meridian | Shanghai | 200030 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Transvaginal electrical stimulation | Device | A neuromuscular stimulation therapy system (PHENIX USB 4,Electronic Concept Lignon Innovation, France) is used for TES |
|
| ID | Term |
|---|---|
| D013119 | Spinal Cord Injuries |
| D059411 | Lower Urinary Tract Symptoms |
| D053159 | Dysuria |
| ID | Term |
|---|---|
| D013118 | Spinal Cord Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D020196 | Trauma, Nervous System |
| D014947 | Wounds and Injuries |
| D020924 | Urological Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided