Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
To date two different instruments are commercially available to measure retinal oxygen saturation and retinal vessel diameters: Dynamic Vessel Analyzer (DVA) and Oxymap. Retinal oxygen saturation analysis is based on spectroscopic evaluation of retinal fundus images. Up to now no data comparing both instruments for the measurement of retinal oxygen saturation and vessel diameter are available in the literature.
Study objectives: To compare retinal oxygenation and retinal vessel diameters in healthy subjects and patients with diabetic retinopathy or retinal vein occlusion between 2 commercially available systems (DVA, Oxymap T1)
Study design: Open pilot study
Study population:
30 healthy volunteers, age 18-80 years 30 type 2 diabetic patients with mild or moderate non-proliferative diabetic retinopathy, age 18-80 years 30 patients with retinal vein occlusion, age 18-80 years
Topically administered medication:
Tropicamide (Mydriaticum "Agepha"®, Agepha, Vienna, Austria), dose: 1-2 drops per study day for dilation of the pupil Oxybuprocainhydrochloride combined with sodium fluorescein (Thilorbin®, Alcon Pharma GmbH, Freiburg, Germany), dose: 1 drop in one eye for measurements of intraocular pressure Nonylacidvanillylamide combined with Nicotinic-acid--ß-butoxyethylester (Finalgon®, Boehringer Ingelheim RCV GmbH & Co KG, Vienna, Austria): topical on the earlobe
Methods:
Dynamic vessel analyzer Oxymap T1 Blood pressure and pulse rate measurement Applanation tonometry Oxygen and carbon dioxide partial pressure measurement in arterialized blood from earlobe
Main outcome variables:
Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1
The motive for this investigation is to compare data between 2 commercially available instruments for the measurement of retinal oxygen saturation and retinal vessel diameter in healthy subjects as well as in patients with ocular disease associated with altered retinal oxygenation. Comparative data from both systems are currently not available. Data from this study will allow the comparison of studies performed with different systems. All oxygen measurement procedures are non-invasive and painless. Hence, the risk/benefit ratio appears to be acceptable.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Healthy subjects | Other | healthy study subjects, age 18-80 years |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dynamic Vessel Analyzer | Other |
| ||
| Oxymap T1 |
| Measure | Description | Time Frame |
|---|---|---|
| Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1 | participants will be followed for the duration of outpatient clinic visit, an expected average of 1 days |
| Measure | Description | Time Frame |
|---|---|---|
| Difference of retinal vessel diameter between DVA and Oxymap T1 | participants will be followed for the duration of outpatient clinic visit, an expected average of 1 days |
Not provided
Inclusion criteria healthy volunteers
Exclusion Criteria:
Any of the following will exclude a subject from the study:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Vienna | Vienna | 1090 | Austria |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| ID | Term |
|---|---|
| D003930 | Diabetic Retinopathy |
| D012170 | Retinal Vein Occlusion |
| ID | Term |
|---|---|
| D012164 | Retinal Diseases |
| D005128 | Eye Diseases |
| D003925 | Diabetic Angiopathies |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D048909 | Diabetes Complications |
| D003920 | Diabetes Mellitus |
| D004700 | Endocrine System Diseases |
| D020246 | Venous Thrombosis |
| D013927 | Thrombosis |
| D016769 | Embolism and Thrombosis |
Not provided
Not provided