Not provided
Not provided
Not provided
Not provided
Not provided
Terminated due to COVID-19
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Optovue | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The objective of this study is to image retinal vascular alterations in patients with retinal disease using the AngioVue OCT-A system and understand the information these images provide. The investigators will image study participants who have retinal diseases with the AngioVue unit (Optovue) and will collect relevant clinical data to understand the nature of the information contained in images obtained on AngioVue. This study being conducted under an abbreviated IDE. The investigators will analyze data using descriptive statistics. Risks related to light exposure will be managed by ensuring that the exposure to the AngioVue light source is well below maximum permissible limits for safe exposure.
OCT is an optical ranging and imaging technique first described in 1991 that has since been used successfully to provide high-resolution, micrometer-scale depth imaging in clinical ophthalmology (and other fields). It can be thought of as the optical analogue of ultrasound imaging. For the ocular posterior segment, OCT provides rapid acquisition of high-resolution, cross-sectional images of the retina that approximate tissue histology. In vivo imaging of the retina with OCT has thus dramatically improved clinicians' diagnostic capabilities, allowing earlier and more accurate diagnosis of disease and more precise assessment of response to therapies over time.
While OCT provides important information on retinal anatomy, it is currently limited in its ability to provide information on retinal vasculature and blood flow. Angiography is the current gold-standard imaging modality for retinal vascular imaging. Angiography involves intravenous injection of a fluorescent dye (typically either fluorescein or indocyanine green for the retinal or choroidal vessels, respectively) that circulates through the body. A light source emitting light at the specific excitation wavelength of the dye is placed in front of the patient's eye, and a camera equipped with a filter corresponding to the emission wavelength of the dye is then used to image vessel morphology and retinal perfusion, either through still images or through a short movie. Angiography provides physiologic information about the retina that complements the anatomical information provided by OCT. While generally well tolerated by most patients, angiography does have drawbacks: it often requires the use of a separate imaging system, it requires several minutes for image acquisition, and it involves intravenous injection of a dye. Patients occasionally experience side effects of intravenous dye administration, including nausea, discomfort, and rarely, anaphylaxis.
Several retinal imaging companies are developing the next generation of OCT technology: OCT angiography (OCT-A). OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid (the vascular plexus subjacent to the retina), without the need for intravenous dye administration. OCT-A platforms currently under development include both spectral domain (SD) and swept-source (SS) based technologies. Whereas SS-based OCT-A utilizes a longer wavelength (~1060 nm) light source, SD-based units use the same light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. (Fremont, CA) has developed one such unit, a customized, high-resolution SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This SSADA algorithm allows for detection of motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. The AngioVue can generate high-quality angiograms of both the retina and choroid. Additionally, this refined method has produced images of the smallest retinal vessels (capillaries) in normal healthy control participants. In this proposed prospective interactive clinical study, we will use the AngioVue unit to image patients and characterize vascular abnormalities that are present in the setting of retinal diseases.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| SD-OCT Angiography | Experimental | Study participants will undergo imaging of both eyes with the AngioVue unit (approximately 60 seconds/eye), per standard operating protocol. Imaging is noncontact, and pharmacologic dilation will not be used for the purposes of this study. In most instances, study participants will undergo only a single imaging session on a single day. However, potential participants will be asked to consent for additional imaging sessions (up to 12) that may occur over the course of subsequent future visits to the clinic. Additionally, study participants will be asked to consent to prospective collection of clinical and demographic data, to correlate findings of OCT-A imaging to subsequent clinical course. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AngioVue SD-OCT | Device | OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid, without intravenous dye administration. SD-OCT units use the light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. has developed a customized SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This detects motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. This unit is being conducted under an abbreviated IDE. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Participants With Image Quality Sensitive Enough to Identify Specific New Vessel Morphology | Day 0 |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Priyatham Mettu, MD | Duke University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Duke Eye Center | Durham | North Carolina | 27710 | United States |
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | SD-OCT Angiography | Study participants will undergo imaging of both eyes with the AngioVue unit (approx. 60 seconds/eye), per standard operating protocol. Imaging is noncontact, and pharmacologic dilation will not be used for the purposes of this study. In most instances, study participants will undergo only a single imaging session on a single day. However, potential participants will be asked to consent for additional imaging sessions (up to 12) that may occur over the course of subsequent future visits to the clinic. Additionally, study participants will be asked to consent to prospective collection of clinical and demographic data, to correlate findings of OCT-A imaging to subsequent clinical course. AngioVue SD-OCT: OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid, without intravenous dye administration. SD-OCT units use the light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. has developed a customized SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This detects motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. This unit is being conducted under an abbreviated IDE. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | SD-OCT Angiography | Study participants will undergo imaging of both eyes with the AngioVue unit (approx. 60 seconds/eye), per standard operating protocol. Imaging is noncontact, and pharmacologic dilation will not be used for the purposes of this study. In most instances, study participants will undergo only a single imaging session on a single day. However, potential participants will be asked to consent for additional imaging sessions (up to 12) that may occur over the course of subsequent future visits to the clinic. Additionally, study participants will be asked to consent to prospective collection of clinical and demographic data, to correlate findings of OCT-A imaging to subsequent clinical course. AngioVue SD-OCT: OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid, without intravenous dye administration. SD-OCT units use the light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. has developed a customized SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This detects motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. This unit is being conducted under an abbreviated IDE. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Number of Participants With Image Quality Sensitive Enough to Identify Specific New Vessel Morphology | Posted | Count of Participants | Participants | Day 0 |
|
Day 0
Any untoward or unfavorable medical occurrence in a participant, including any abnormal sign (for example, abnormal physical exam or laboratory finding), symptom, or disease, temporally associated with the participant's participation in the research, whether or not considered related to the participant's participation in the research.
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | SD-OCT Angiography | Study participants will undergo imaging of both eyes with the AngioVue unit (approx. 60 seconds/eye), per standard operating protocol. Imaging is noncontact, and pharmacologic dilation will not be used for the purposes of this study. In most instances, study participants will undergo only a single imaging session on a single day. However, potential participants will be asked to consent for additional imaging sessions (up to 12) that may occur over the course of subsequent future visits to the clinic. Additionally, study participants will be asked to consent to prospective collection of clinical and demographic data, to correlate findings of OCT-A imaging to subsequent clinical course. AngioVue SD-OCT: OCT-A allows noninvasive, high-resolution imaging of the microvasculature of the retina and choroid, without intravenous dye administration. SD-OCT units use the light source used in commercially available and FDA-cleared OCT units on a modified platform. Optovue, Inc. has developed a customized SD-OCT system that implements a novel algorithm, the amplitude-based method of split-spectrum amplitude-decorrelation angiography (SSADA) for OCT-A. This detects motion in the blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. Optovue has integrated the novel SSADA algorithm into their commercially approved RTVue SD-OCT unit for their OCT-A unit, the AngioVue. This unit is being conducted under an abbreviated IDE. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Priyatham Mettu | Duke Eye Center | 919-684-9010 | priyatham.mettu@duke.edu |
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | May 18, 2018 | Feb 14, 2022 | Prot_SAP_000.pdf |
Not provided
| ID | Term |
|---|---|
| D008268 | Macular Degeneration |
| D003930 | Diabetic Retinopathy |
| D012170 | Retinal Vein Occlusion |
| ID | Term |
|---|---|
| D012162 | Retinal Degeneration |
| D012164 | Retinal Diseases |
| D005128 | Eye Diseases |
| D003925 | Diabetic Angiopathies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
|
| Region of Enrollment | Count of Participants | Participants |
|
|
|
| 0 |
| 39 |
| 0 |
| 39 |
| 0 |
| 39 |
Not provided
Not provided
| D014652 |
| Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D048909 | Diabetes Complications |
| D003920 | Diabetes Mellitus |
| D004700 | Endocrine System Diseases |
| D020246 | Venous Thrombosis |
| D013927 | Thrombosis |
| D016769 | Embolism and Thrombosis |