The endotracheal tube (ETT) leak test (LT), or audible leak test is a widely performed assessment to verify appropriate tube size in neonates, infants and children. However, many factors are known to influence the audible leak test. Even though the test is widely performed, the accuracy has not been evaluated.
The endotracheal tube (ETT) leak test (LT), or audible leak when the peak airway pressures reach 15-30 cmH2O, is a commonly performed assessment to confirm that an endotracheal tube size is appropriate for a child in order to minimize the risk of airway injury and adverse events after removal of ETT. Many factors are known to affect the results of the leak test and variation in results among experienced anesthesiologists may be as great as 38%, but the accuracy of the audible leak test by directly observing the presence of a leak around the ETT has not been evaluated. This study will attempt to use direct visualization of the air leak to correlate to and assess the accuracy of the audible air leak test.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Endotracheal Leak | Assess for Audible Endotracheal Leak; Assess for Endotracheal Leak with direct visualization under rigid bronchoscope |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Assess for Audible Endotracheal Leak | Other | In supine position, the head will be positioned in neutral position. With fresh gas flow at 2-5L/min, and pop off valve in the anesthesia machine closed and pressure in the inspiratory circuit is slowly increased until an audible leak is heard at the mouth. That pressure will be recorded. |
| Measure | Description | Time Frame |
|---|---|---|
| Primary Objective Evidence of an audible endotracheal leak and/or direct visualized endotracheal leak | Evidence of an audible endotracheal leak and/or direct visualized endotracheal leak using a flexible nasal laryngoscope positioned superior to the laryngeal inlet. | one year. |
| Measure | Description | Time Frame |
|---|---|---|
| Secondary Objective Evidence suggesting a relationship between the presence of an audible leak and direct visualization for cuffed and uncuffed TT's | Evidence suggesting a relationship between the presence of an audible leak and direct visualization for cuffed and uncuffed TT's. | one year. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Children aged between 1 month (post-natal) and 8 years scheduled for ENT surgery requiring general anesthesia with an endotracheal tube.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Madhankumar Sathyamoorthy, MBBS, MS | Univeristy of Mississippi Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Mississippi Medical Center | Jackson | Mississippi | 39216 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 16719880 | Background | Suominen P, Taivainen T, Tuominen N, Voipio V, Wirtavuori K, Hiller A, Korpela R, Karjalainen T, Meretoja O. Optimally fitted tracheal tubes decrease the probability of postextubation adverse events in children undergoing general anesthesia. Paediatr Anaesth. 2006 Jun;16(6):641-7. doi: 10.1111/j.1460-9592.2005.01832.x. | |
| 4027762 |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D053120 | Respiratory Aspiration |
| ID | Term |
|---|---|
| D012120 | Respiration Disorders |
| D012140 | Respiratory Tract Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Assess for Endotracheal Leak with direct visualization under rigid bronchoscope | Other | In the same patient position, a flexible nasal laryngoscope will be inserted and positioned superior to the laryngeal inlet by the surgeon. With fresh gas flow at 2-5L/min, and pop off valve in the anesthesia machine closed, the pressure in the inspiratory circuit will be increased slowly until a leak around the TT will be visualized by inspecting the supraglottic area for bubbles or air movement around the TT. The peak pressure at which leak is observed physically will be recorded. This is the end of the study. |
|
| Finholt DA, Henry DB, Raphaely RC. Factors affecting leak around tracheal tubes in children. Can Anaesth Soc J. 1985 Jul;32(4):326-9. doi: 10.1007/BF03011335. |
| 8269566 | Background | Schwartz RE, Stayer SA, Pasquariello CA. Tracheal tube leak test--is there inter-observer agreement? Can J Anaesth. 1993 Nov;40(11):1049-52. doi: 10.1007/BF03009476. |