Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Central blood pressure and pulse wave velocity were measured using a Complior Analyse device in Short and Long-term after kidney transplantation.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients after kidney transplantation | Short and Long-term results containing first 10 years after KTx. |
| |
| Healthy subjects | Medical staff: medical doctors, nurses |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Device: Complior Analyse System | Device | Monitoring of Arterial Stiffness and Central Aortic Pressure |
|
| Measure | Description | Time Frame |
|---|---|---|
| Differences in carotid-femoral pulse wave velocity [m/s] in short and long-term postoperative period. | Measurements will be performed in routine visits in Transplant Centre. | 1 day |
| Measure | Description | Time Frame |
|---|---|---|
| Differences in central aortic pressure [mmHg] in short and long-term postoperative period. | Measurements will be performed in routine visits in Transplant Centre. | 1 day |
| Differences in central aortic pressure [mmHg] and cuff blood pressure [mmHg] in short and long-term postoperative period. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
A total of 100 consecutive patients admitted to routine visin in Transplant Centre and 30 healthy subjects were included in this study.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Łukasz Czyżewski, PhD | Medical University of Warsaw | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Warsaw | Warsaw | Mazovian | 02-091 | Poland |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 25365639 | Background | Czyzewski L, Sanko-Resmer J, Wyzgal J, Kurowski A. Comparative analysis of hypertension and its causes among renal replacement therapy patients. Ann Transplant. 2014 Nov 3;19:556-68. doi: 10.12659/AOT.891248. | |
| 24770703 | Background | Czyzewski L, Wyzgal J, Kolek A. Evaluation of selected risk factors of cardiovascular diseases among patients after kidney transplantation, with particular focus on the role of 24-hour automatic blood pressure measurement in the diagnosis of hypertension: an introductory report. Ann Transplant. 2014 Apr 28;19:188-98. doi: 10.12659/AOT.890189. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Tanita BC 418- Bioelectrical impedance analysis | Device | The device measured the size of total body water (TBW), fat mass (FM%), visceral fat%, fat free mass (FFM), and basal metabolic rate (BMR) (kcal). |
|
Measurements will be performed in routine visits in Transplant Centre. |
| 1 day |
| 25382249 | Background | Czyzewski L, Sanko-Resmer J, Wyzgal J, Kurowski A. Assessment of health-related quality of life of patients after kidney transplantation in comparison with hemodialysis and peritoneal dialysis. Ann Transplant. 2014 Nov 9;19:576-85. doi: 10.12659/AOT.891265. |
| ID | Term |
|---|---|
| D006973 | Hypertension |
| D000075222 | Essential Hypertension |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided