The objective of the study is to make up the technique blind spots of the bipolar radiofrequency ablation in the surgical treatment of atrial fibrillation with rheumatic heart disease by using argon beam coagulator. And to improve the rates of cardioversion of atrial fibrillation after surgery, to decrease the long-term recurrence rate of atrial fibrillation and to compare the early term and long term outcomes of bipolar radiofrequency ablation and bipolar radiofrequency plus argon beam coagulator ablation.
Atrial fibrillation(AF) is the most common sustained arrhythmia. It can cause reduced heart function and increase the risk of thromboembolism. About 60% of patients with rheumatic heart disease have persistent AF.AF surgery is an effective intervention for patients with all types of AF undergoing concomitant cardiac surgery. AF surgery can reduce the risks of heart of stroke and heart failure and promote longer survival. Bipolar radiofrequency ablation is one of the most effective ways. But in the investigators' early study we find that there are technique blind spots in the left atrial ablation and right atrial ablation. In the bipolar left atrial linear ablation performed along the lower edge of interatrial groove incision up to the mitral annulus, there is a gap between the ends of the ablation line to the mitral annulus. And if the investigators use bipolar radiofrequency pliers it may injure the lcx left circumflex artery and left ventricular. In the bipolar right atrial radiofrequency ablation, the linear ablation performed along the lower edge of the coronary sinus ostium up to the inferoseptal commissure and the linear performed through the vertical incision on anterior wall of the right atrium up to the tricuspid annulus, there is also a gap between the end of the end of the ablation line and the tricuspid annulus. These gaps are one of factors of the recurrence of AF.
Argon beam coagulator is one of the most common hemostasis tools in heart surgery. It can also cause coagulation necrosis of the myocardium and do not do harm to the nearly myocardium the same as bipolar radiofrequency ablation. In the investigators' early study the investigators use the coagulation de plasma argon to burn the endocardium. And in the investigators' 6 mouth follow up, the rate of cardioversion is 90%. In this study the investigators plan to use argon beam coagulator to ablate these gaps.
The objective of the study is to make up the technique blind spots of the bipolar radiofrequency ablation in the surgical treatment of atrial fibrillation with rheumatic heart disease by using argon beam coagulator. And to improve the rates of cardioversion of atrial fibrillation after surgery, to decrease the long-term recurrence rate of atrial fibrillation and to compare the early term and long term outcomes of bipolar radiofrequency ablation and bipolar radiofrequency plusargon beam coagulator ablation.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Argon beam coagulator ablation group | Experimental | In the bipolar left atrial radiofrequency ablation, when the linear ablation was performed through along the lower edge of interatrial groove incision up to the mitral annulus, there is a gap between the ends of the ablation line and the mitral annulus And in the bipolar right atrial radiofrequency ablation, when the linear ablation was performed along the lower edge of the coronary sinus ostium up to the inferoseptal commissure and through the vertical incision on anterior wall of the right atrium up to the tricuspid annulus. There also have gaps between ends of the ablation line and the tricuspid annulus. In the experimental group the investigators plan to use conventional bipolar radiofrequency ablation and use argon beam coagulator to ablate these gaps. |
|
| Bipolar radiofrequency ablation group | Experimental | Only use conventional bipolar radiofrequency ablation and do not deal with these gaps. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| argon beam coagulator ablation | Procedure | The investigators plan to use argon beam coagulator ablation plus bipolar radiofrequency ablation in the argon beam coagulator ablation group. |
| Measure | Description | Time Frame |
|---|---|---|
| electrocardiogram:rates of cardioversion of atrial fibrillation | The investigators plan to check the electrocardiogram of all the 200 individuals involved in our study 3 years after surgery to ensure the rate of cardioversion of atrial fibrillation | 3 years after surgery |
| Measure | Description | Time Frame |
|---|---|---|
| surgery time | during surgery | |
| cardiopulmonary bypass time | during surgery | |
| long-term recurrence rate of atrial fibrillation |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Lin Chen | Contact | +86-23-68774107 | chenlin_xq@aliyun.com | |
| Mingwen Li | Contact | +86-23-68774107 | 509044544@qq.com |
| Name | Affiliation | Role |
|---|---|---|
| Lin Chen | Department of Cardiovascular Surgery, Xinqiao Hospital, Third Military Medical University | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Lin Chen | Recruiting | Chongqing | Chongqing Municipality | 400037 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| Background | [1] Hong L, Lin C, Yinbing X, et al. Early Efficacy Analysis of Biatrial Ablation versus Left and Simplified Right Atrial Ablation for Atrial Fibrillation Treatment in Patients with Rheumatic Heart Disease. Heart Lung Circ. 2015 [2] Hussein AA, Wazni OM, Harb S, Joseph L, Chamsi-Pasha M, Bhargava M,et al. Radiofrequency Ablation of Atrial Fibrillation in Patients With Mechanical Mitral Valve Prostheses. J Am Coll Cardio 2011;58:596-602 [3] PasicM, Bergs P, Muller P, et al. Intraoperative radiofrequencymaze ablation for trail fibrillation: the berlin modification [J]. Ann Thorac Surg,2001,72(5):1484-1490 [4] WilliamsM R, GarridoM, OzMC, et al. Alternative energy source for surgical atrial ablation [J].J Card Surg,2004,19(3):201-206 [5] Nitta T. Surgery for trail fibrillation: a worldwide review [J]. Semin Thorac Cardiovasc Surg, 2007, 19(1):3-8 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| bipolar radiofrequency ablation | Procedure | The investigators only use bipolar radiofrequency ablation in the left and right atrial radiofrequency ablation. |
|
| argon beam coagulator (American,Valleylab) | Device | Argon beam coagulator(American,Valleylab)will be used in the argon beam coagulator ablation group |
|
| bipolar radiofrequency (AtricuteTM) | Device | The investigators plan to use bipolar radiofrequency(AtricuteTM) in the bipolar radiofrequency group |
|
| 3 years |
| complication after surgery | Number of adverse events as an assessment of complications after surgery | 3 years |
| radiofrequency ablation time | during surgery |
| hospital stays | participants will be followed for the duration of hospital stay,an expected average of 4 weeks | 4 weeks |
| ID | Term |
|---|---|
| D001281 | Atrial Fibrillation |
| ID | Term |
|---|---|
| D001145 | Arrhythmias, Cardiac |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
| ID | Term |
|---|---|
| D057908 | Argon Plasma Coagulation |
| ID | Term |
|---|---|
| D004564 | Electrocoagulation |
| D002425 | Cautery |
| D013812 | Therapeutics |
| D006489 | Hemostatic Techniques |
| D055011 | Ablation Techniques |
| D013514 | Surgical Procedures, Operative |
| D006488 | Hemostasis, Surgical |
Not provided
Not provided