The aim of this prospective, interventional study is to assess the feasibility and safety of the Esophageal Cooling Device in patients from suffering from traumatic brain injury who the treating physician is treating with targeted temperature management. Comparison of outcomes will be made to historical controls. The primary outcome is the feasibility of inducing, maintaining, and rewarming patients from targeted temperature management using the Esophageal Cooling Device (cooling rate, rewarming rate, and the percent of time within goal temperature during the goal-temperature maintenance period). Evaluation of adverse events (including cardiac arrhythmias, severe bradycardia, myocardial infarction/re-infarction, dysphagia, odynophagia, aspiration pneumonia, non-aspiration pneumonia, reflux, esophageal injury, and esophagitis) will be closely monitored during the whole period of targeted temperature management (secondary endpoint).
Controlling patient's body temperature, and in particular, reducing body temperature in a treatment referred to as targeted temperature management, has been shown to improve outcomes for many conditions, including neonatal hypoxic ischemic encephalopathy, cardiac arrest, and traumatic brain injury. However, available modalities for inducing targeted temperature management have a number of technical, logistical, and financial barriers. The Esophageal Cooling Device is a multi-chambered silicone tube placed in the esophagus that provides a highly efficient heat transfer to or from a patient.
Traumatic brain injury (TBI) is a major cause of death and severe disability throughout the world. Current methods of traumatic brain injury treatment include reduction of brain swelling and edema, both by surgical means, as well as by reduction of temperature and avoidance of fever. Methods used to reduce temperature and control fever include surface devices, such as ice packs and water circulating blankets, and intravascular catheters, which are placed into a blood vessel.
The esophagus is in close proximity to blood flow from the heart and great vessels, and the Esophageal Cooling Device (ECD) is designed to take advantage of this heat exchange environment. The ECD's ability to decompress the stomach and avoid distention of the esophagus away from the device ensures good contact with the esophageal mucosa, and thus maximizes heat transfer from the patient. The ECD replaces the standard gastric tube which is placed in the target patient population as a routine standard of care, is made of standard medical-grade silicone, and is generally similar in size and shape to the gastric tubes currently used. Initial mathematical, animal, and human data have shown strong support for the efficacy and safety of the ECD.
The aim of this prospective, interventional study is to assess the feasibility and safety of the Esophageal Cooling Device in patients from suffering from traumatic brain injury who the treating physician is treating with targeted temperature management. Comparison of outcomes will be made to historical controls. The primary outcome is the feasibility of inducing, maintaining, and rewarming patients from targeted temperature management using the Esophageal Cooling Device (cooling rate, rewarming rate, and the percent of time within goal temperature during the goal-temperature maintenance period). Evaluation of adverse events (including cardiac arrhythmias, severe bradycardia, myocardial infarction/re-infarction, dysphagia, odynophagia, aspiration pneumonia, non-aspiration pneumonia, reflux, esophageal injury, and esophagitis) will be closely monitored during the whole period of targeted temperature management (secondary endpoint).
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intervention | Experimental | The placement of the Esophageal Cooling Device will follow standard recommendations as per Instructions for Use. The Esophageal Cooling Device will be connected to the appropriate console (Meditherm III, Blanketrol II, or Blanketrol III). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Esophageal Cooling Device (ECD), manufactured by Advanced Cooling Therapy, Inc. | Device | Use of the Esophageal Cooling Device for control of patient temperature. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Time to Initiation of Temperature Management | Time to initiation of targeted temperature management, as measured from the time a decision is made to begin targeted temperature management, to the time the esophageal cooling device is in place. | 30 days |
| Measure | Description | Time Frame |
|---|---|---|
| Composite of Performance Outcomes | Secondary performance outcomes include the feasibility of inducing, maintaining, and rewarming patients from targeted temperature management using the Esophageal Cooling Device. Specifically, cooling rate, rewarming rate, and the percent of time during the goal- temperature maintenance period within 1°C of goal temperature (typically 33°C, but with some centers using anywhere from 32°C to 36°C) will be measured. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Oleksandr Tsarev, MD | Dnipropetrivsk State Medical Academy based on Dnipropetrivsk Regional Clinical Hospital n.a. Mechnikov, Department of Anesthesiology and Intencive Care Medicine, 14 Octoberskay sq., Dnipropetrivsk 49600, Ukraine | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Dnipropetrivsk State Medical Academy based on Dnipropetrivsk Regional Clinical Hospital | Dnipro | Ukraine |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 22972067 | Background | Arrich J, Holzer M, Havel C, Mullner M, Herkner H. Hypothermia for neuroprotection in adults after cardiopulmonary resuscitation. Cochrane Database Syst Rev. 2012 Sep 12;(9):CD004128. doi: 10.1002/14651858.CD004128.pub3. | |
| 24742169 | Background | Crossley S, Reid J, McLatchie R, Hayton J, Clark C, MacDougall M, Andrews PJ. A systematic review of therapeutic hypothermia for adult patients following traumatic brain injury. Crit Care. 2014 Apr 17;18(2):R75. doi: 10.1186/cc13835. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Intervention | The placement of the Esophageal Cooling Device will follow standard recommendations as per Instructions for Use. The Esophageal Cooling Device will be connected to the appropriate console (Meditherm III, Blanketrol II, or Blanketrol III). Esophageal Cooling Device (ECD), manufactured by Advanced Cooling Therapy, Inc.: Use of the Esophageal Cooling Device for control of patient temperature. |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Dec 8, 2014 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 36 hours |
| Composite of Safety Outcomes | Secondary safety outcomes include evaluation of adverse events including the following: cardiac arrhythmias, severe bradycardia, myocardial infarction/re-infarction, dysphagia, odynophagia, aspiration pneumonia, non-aspiration pneumonia, reflux, esophageal injury, and esophagitis. | Assessed over 36 hours of treatment and up to 30 days of follow-up. |
| 24004918 | Background | Andrews PJ, Sinclair LH, Harris B, Baldwin MJ, Battison CG, Rhodes JK, Murray G, De Backer D; Eurotherm3235Trial collaborators. Study of therapeutic hypothermia (32 to 35 degrees C) for intracranial pressure reduction after traumatic brain injury (the Eurotherm3235Trial): outcome of the pilot phase of the trial. Trials. 2013 Sep 3;14:277. doi: 10.1186/1745-6215-14-277. |
| 18539227 | Background | Polderman KH. Induced hypothermia and fever control for prevention and treatment of neurological injuries. Lancet. 2008 Jun 7;371(9628):1955-69. doi: 10.1016/S0140-6736(08)60837-5. |
| 19535955 | Background | Badjatia N. Hyperthermia and fever control in brain injury. Crit Care Med. 2009 Jul;37(7 Suppl):S250-7. doi: 10.1097/CCM.0b013e3181aa5e8d. |
| 23827887 | Background | Kulstad E, Metzger AK, Courtney DM, Rees J, Shanley P, Matsuura T, McKnite S, Lurie K. Induction, maintenance, and reversal of therapeutic hypothermia with an esophageal heat transfer device. Resuscitation. 2013 Nov;84(11):1619-24. doi: 10.1016/j.resuscitation.2013.06.019. Epub 2013 Jul 1. |
| 25660954 | Background | Markota A, Kit B, Fluher J, Sinkovic A. Use of an oesophageal heat transfer device in therapeutic hypothermia. Resuscitation. 2015 Apr;89:e1-2. doi: 10.1016/j.resuscitation.2015.01.032. Epub 2015 Feb 7. No abstract available. |
| COMPLETED |
|
| NOT COMPLETED |
|
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Intervention | The placement of the Esophageal Cooling Device will follow standard recommendations as per Instructions for Use. The Esophageal Cooling Device will be connected to the appropriate console (Meditherm III, Blanketrol II, or Blanketrol III). Esophageal Cooling Device (ECD), manufactured by Advanced Cooling Therapy, Inc.: Use of the Esophageal Cooling Device for control of patient temperature. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean | Standard Deviation | years |
| |||||||||||||||||
| Sex: Female, Male | Count of Participants | Participants |
| ||||||||||||||||||
| Race and Ethnicity Not Collected | Race and Ethnicity were not collected from any participant. | Count of Participants | Participants |
| |||||||||||||||||
| Region of Enrollment | Number | participants |
| ||||||||||||||||||
| BMI | Mean | Standard Deviation | kg/m^2 |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Time to Initiation of Temperature Management | Time to initiation of targeted temperature management, as measured from the time a decision is made to begin targeted temperature management, to the time the esophageal cooling device is in place. | Posted | Mean | Standard Deviation | hours | 30 days |
|
|
| ||||||||||||||||||||||||||
| Secondary | Composite of Performance Outcomes | Secondary performance outcomes include the feasibility of inducing, maintaining, and rewarming patients from targeted temperature management using the Esophageal Cooling Device. Specifically, cooling rate, rewarming rate, and the percent of time during the goal- temperature maintenance period within 1°C of goal temperature (typically 33°C, but with some centers using anywhere from 32°C to 36°C) will be measured. | Not Posted | 36 hours | Participants | |||||||||||||||||||||||||||||||
| Secondary | Composite of Safety Outcomes | Secondary safety outcomes include evaluation of adverse events including the following: cardiac arrhythmias, severe bradycardia, myocardial infarction/re-infarction, dysphagia, odynophagia, aspiration pneumonia, non-aspiration pneumonia, reflux, esophageal injury, and esophagitis. | Not Posted | Assessed over 36 hours of treatment and up to 30 days of follow-up. | Participants |
30 days
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Intervention | The placement of the Esophageal Cooling Device will follow standard recommendations as per Instructions for Use. The Esophageal Cooling Device will be connected to the appropriate console (Meditherm III, Blanketrol II, or Blanketrol III). Esophageal Cooling Device (ECD), manufactured by Advanced Cooling Therapy, Inc.: Use of the Esophageal Cooling Device for control of patient temperature. Adverse events specifically monitored included the following: cardiac arrhythmias, severe bradycardia, myocardial infarction/reinfarction, dysphagia, odynophagia, aspiration pneumonia, nonaspiration pneumonia, reflux, esophageal injury, and esophagitis. | 0 | 12 | 0 | 12 | 1 | 12 |
Not provided
| Term | Organ System | Source Vocabulary | Assessment Type | Notes | Statistical Information |
|---|---|---|---|---|---|
| a small volume left hydrothorax | Respiratory, thoracic and mediastinal disorders | Non-systematic Assessment |
|
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Alexander Tsarev | Department of Anesthesiology & Intensive Care Medicine, Dnipropetrovsk Medical Academy | +38 057 701 52 00 | tsarev03@rambler.ru |
| Jul 19, 2021 |
| Prot_SAP_000.pdf |
| ID | Term |
|---|---|
| D000070642 | Brain Injuries, Traumatic |
| ID | Term |
|---|---|
| D001930 | Brain Injuries |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D006259 | Craniocerebral Trauma |
| D020196 | Trauma, Nervous System |
| D014947 | Wounds and Injuries |
Not provided
Not provided