Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of the present study was to compare the effectiveness of two alignment sequences with thermal activated archwires with different Af temperatures applied for the correction of mandibular anterior crowding
A parallel randomized clinical trial was conducted involving 42 patients ages 15 to 25 years (mean: 19.5 years) who required orthodontic treatment including the correction of mandibular anterior crowding. Eligibility criteria were no active caries, exemplary hygiene, non- extraction in the lower arch and no significant tooth size or shape abnormalities. Outcome: The primary outcome was the degree of crowding measured on plaster casts using Little's Irregularity Index. The secondary outcome was crowding survival time until the occurrence of correction in a six-month period. Randomization: The patients were randomly allocated to the different groups using sealed opaque envelopes. Blinding: The patients were blinded to the group to which they were allocated. Intervention: Patients were treatment with a pre-adjusted appliance (0.022 in- Roth prescription). Two nickel-titanium alignment and leveling sequences were employed - NiTi archwire: 0.012 in and 0.019 X 0.025 in; and thermal activated NiTi archwires: 0.018 in and 0.016 X 0.022 in with different austenite finish temperatures (37ºC and 35ºC), which formed the different study groups.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| NiTi Af 37ºC | Experimental | Patients were treatment with fixed orthodontics appliance and arch wire. Two nickel-titanium alignment and leveling sequences were employed - NiTi archwire: 0.012 in and 0.019 X 0.025 in; and thermal activated NiTi archwires: 0.018 in and 0.016 X 0.022 in with different austenite finish temperatures (37ºC). |
|
| NiTi Af 35ºC | Experimental | Patients were treatment fixed orthodontics appliance and arch wire. Two nickel-titanium alignment and leveling sequences were employed - NiTi archwire: 0.012 in and 0.019 X 0.025 in; and thermal activated NiTi archwires: 0.018 in and 0.016 X 0.022 in with different austenite finish temperatures (35ºC) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Fixed orthodontics appliance and arch wire | Device | Two nickel-titanium alignment and leveling sequences were employed |
|
| Measure | Description | Time Frame |
|---|---|---|
| Degree of crowding measured on plaster casts using Little's Irregularity Index | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| crowding survival time | six months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Apr 15, 2016 | |
| Unrelease | Yes | |
| Release | Apr 27, 2016 | |
| Reset | Jun 6, 2016 | |
| Release | Jul 5, 2016 | |
| Reset | Aug 12, 2016 | |
| Release | Mar 6, 2017 | |
| Reset | Apr 17, 2017 | |
| Release | Sep 21, 2017 | |
| Reset | Oct 20, 2017 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Apr 15, 2016 | Yes | |||
| Apr 27, 2016 |
| ID | Term |
|---|---|
| D003441 | Crowding |
| ID | Term |
|---|---|
| D013037 | Spatial Behavior |
| D001519 | Behavior |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Jun 6, 2016 |
| Jul 5, 2016 | Aug 12, 2016 |
| Mar 6, 2017 | Apr 17, 2017 |
| Sep 21, 2017 | Oct 20, 2017 |