Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Society of Family Planning | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to determine whether Nitrous Oxide is effective in achieving pain control and satisfaction among nulliparous women getting the intrauterine device (IUD).
Long acting reversible contraception (LARC) including the IUD provides several advantages that may be attractive to women. These include non-daily use, rapid reversibility and low failure rates. The American College of Obstetricians and Gynecologists (ACOG) endorses the use of IUDs among adolescents and nulliparous women, dispelling the myth that IUD use is contraindicated in this population.
Rates of IUD uptake among nulliparous women have not been reported. There are some barriers that may help explain the low uptake of IUDs by teens and nulliparous women, including fear of pain during IUD insertion. This concern is also voiced by providers who perceive pain with IUD insertion to be higher among nulliparous women (Allen, Goldberg et al. 2009).
There is limited evidence comparing subjective pain scores with IUD insertion between nulliparous versus parous women. However, there have been a number of studies evaluating the efficacy of misoprostol, non steroidal anti-inflammatory drugs and local anesthesia in reducing pain during IUD insertion. These included comparisons of pain scores between both nulliparous and multiparous women and reported pain scores by group. These studies have failed to demonstrate evidence that any of the aforementioned interventions significantly reduce pain scores compared to placebo (Allen et al. 2009). We conclude that pain with IUD insertion among nulliparous and adolescent women is within the high range of pain scale measurement standards. Therefore, further investigations of optimizing pain management during this procedure are warranted in order to lead to increased acceptability and adoption of IUDs among this population of women.
Nitrous oxide (NO) is an inhaled gas administered with oxygen in a fixed ratio for analgesia and sedation. It has been used for many years for procedural analgesia and anesthesia in outpatient settings and it reduces anxiety, the perception of pain and alters consciousness. It is attractive for the clinic setting as it demonstrates rapid induction and rapid resolution, allows for patient control of use, exhibits few side effects and boasts a benign safety profile in the setting of scavenging systems and open air clinics. Furthermore, NO systems are relatively inexpensive and noninvasive.
For all these reasons, NO seems to be an ideal approach for pain management with IUD insertion for nulliparous women. No studies have investigated the use of NO in this context. The aim of our study is to objectively identify pain reduction scores and satisfaction with NO use compared to typical insertion practices during IUD insertion for nulliparous women.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Oxygen (Placebo) | Placebo Comparator | 100% oxygen will be administered via disposable scented nasal masks 2 minutes before, throughout and 3-5 minutes after procedure. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. |
|
| Nitrous Oxide (NO) | Experimental | Nitrous Oxide in a fixed dose ratio of 50% nitrous/50% oxygen will be administered via disposable scented nasal masks 2 minutes before and throughout the procedure; 100% oxygen will be given after the procedure for 3-5 minutes. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| IUD insertion | Procedure | The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. |
| Measure | Description | Time Frame |
|---|---|---|
| Mean Maximum Procedural Pain Scores | Pain is assessed using a 0-100mm VAS with anchors 0 equals no pain and 100 equals worst pain imaginable. The minimal clinically important difference in pain for this study was set at 15mm. | 2 minutes after the procedure. |
| Measure | Description | Time Frame |
|---|---|---|
| Patient Satisfaction With Over-all Pain Control With IUD Insertion - VAS | Satisfaction will be measured using a 100mm Visual Analog Scale (VAS), with anchors 0mm for very satisfied and 100mm for very dissatisfied. | Prior to clinic discharge, which is an average of 15 minutes after the procedure |
| Baseline Mean Pain Scores |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Rameet Singh, MD MPH | UNM Division of Family Planning | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Center for Reproductive Health | Albuquerque | New Mexico | 87106 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19527902 | Background | Allen RH, Goldberg AB, Grimes DA. Expanding access to intrauterine contraception. Am J Obstet Gynecol. 2009 Nov;201(5):456.e1-5. doi: 10.1016/j.ajog.2009.04.027. Epub 2009 Jun 13. | |
| 19588429 | Background | Allen RH, Bartz D, Grimes DA, Hubacher D, O'Brien P. Interventions for pain with intrauterine device insertion. Cochrane Database Syst Rev. 2009 Jul 8;(3):CD007373. doi: 10.1002/14651858.CD007373.pub2. |
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Oxygen (Placebo) | 100% oxygen will be administered via disposable scented nasal masks 2 minutes before, throughout and 3-5 minutes after procedure. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Oxygen: 100% oxygen via nasal mask. |
| FG001 | Nitrous Oxide (NO) | Nitrous Oxide in a fixed dose ratio of 50% nitrous/50% oxygen will be administered via disposable scented nasal masks 2 minutes before and throughout the procedure; 100% oxygen will be given after the procedure for 3-5 minutes. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Nitrous oxide: Given in a fixed dose ratio of 50% nitrous oxide/50% oxygen via nasal mask. |
| Title | Milestones | Reasons Not Completed | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Oxygen (Placebo) | 100% oxygen will be administered via disposable scented nasal masks 2 minutes before, throughout and 3-5 minutes after procedure. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Oxygen: 100% oxygen via nasal mask. |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes |
|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean |
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | Mean Maximum Procedural Pain Scores | Pain is assessed using a 0-100mm VAS with anchors 0 equals no pain and 100 equals worst pain imaginable. The minimal clinically important difference in pain for this study was set at 15mm. | Posted | Mean | Standard Deviation | units on a scale | 2 minutes after the procedure. |
|
Not provided
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Oxygen (Placebo) | 100% oxygen will be administered via disposable scented nasal masks 2 minutes before, throughout and 3-5 minutes after procedure. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Oxygen: 100% oxygen via nasal mask. |
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Sunderjeet Kaur | Division of Family Planning, University of New Mexico | skaur@salud.unm.edu |
Not provided
| ID | Term |
|---|---|
| D017060 | Patient Satisfaction |
| ID | Term |
|---|---|
| D000074822 | Treatment Adherence and Compliance |
| D015438 | Health Behavior |
| D001519 | Behavior |
Not provided
Not provided
| ID | Term |
|---|---|
| D011206 | Povidone-Iodine |
| D002710 | Chlorhexidine |
| D010100 | Oxygen |
| D009609 | Nitrous Oxide |
| ID | Term |
|---|---|
| D007466 | Iodophors |
| D017613 | Iodine Compounds |
| D007287 | Inorganic Chemicals |
| D011145 | Polyvinyls |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| Povidone-Iodine | Drug | Povidone-Iodine 10% w/w antiseptic swab for the cervix prior to IUD insertion. |
|
|
| Chlorhexidine | Drug | For patients with allergy to iodine - 2% w/v chlorhexidine gluconate and 70% v/v isopropyl alcohol antiseptic swab for the cervix prior to IUD insertion. |
|
|
| Oxygen | Other | 100% oxygen via nasal mask. |
|
| Nitrous oxide | Other | Given in a fixed dose ratio of 50% nitrous oxide/50% oxygen via nasal mask. |
|
Baseline pain scores prior to IUD insertion is assessed using a 0-100mm VAS with anchors 0 equals no pain and 100 equals worst pain imaginable. The minimal clinically important difference in pain for this study was set at 15mm. |
| Before the IUD insertion procedure |
| 27481016 | Derived | Singh RH, Thaxton L, Carr S, Leeman L, Schneider E, Espey E. A randomized controlled trial of nitrous oxide for intrauterine device insertion in nulliparous women. Int J Gynaecol Obstet. 2016 Nov;135(2):145-148. doi: 10.1016/j.ijgo.2016.04.014. Epub 2016 Jul 16. |
| BG001 | Nitrous Oxide (NO) | Nitrous Oxide in a fixed dose ratio of 50% nitrous/50% oxygen will be administered via disposable scented nasal masks 2 minutes before and throughout the procedure; 100% oxygen will be given after the procedure for 3-5 minutes. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Nitrous oxide: Given in a fixed dose ratio of 50% nitrous oxide/50% oxygen via nasal mask. |
| BG002 | Total | Total of all reporting groups |
| years |
|
| Sex: Female, Male | Count of Participants | Participants |
|
| Region of Enrollment | Number | participants |
|
| OG001 | Nitrous Oxide (NO) | Nitrous Oxide in a fixed dose ratio of 50% nitrous/50% oxygen will be administered via disposable scented nasal masks 2 minutes before and throughout the procedure; 100% oxygen will be given after the procedure for 3-5 minutes. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Nitrous oxide: Given in a fixed dose ratio of 50% nitrous oxide/50% oxygen via nasal mask. |
|
|
| Secondary | Patient Satisfaction With Over-all Pain Control With IUD Insertion - VAS | Satisfaction will be measured using a 100mm Visual Analog Scale (VAS), with anchors 0mm for very satisfied and 100mm for very dissatisfied. | Posted | Mean | Standard Deviation | units on a scale | Prior to clinic discharge, which is an average of 15 minutes after the procedure |
|
|
|
| Secondary | Baseline Mean Pain Scores | Baseline pain scores prior to IUD insertion is assessed using a 0-100mm VAS with anchors 0 equals no pain and 100 equals worst pain imaginable. The minimal clinically important difference in pain for this study was set at 15mm. | Posted | Mean | Standard Deviation | units on a scale | Before the IUD insertion procedure |
|
|
|
| 0 |
| 40 |
| 0 |
| 40 |
| EG001 | Nitrous Oxide (NO) | Nitrous Oxide in a fixed dose ratio of 50% nitrous/50% oxygen will be administered via disposable scented nasal masks 2 minutes before and throughout the procedure; 100% oxygen will be given after the procedure for 3-5 minutes. If you are randomized to this group, you will undergo the IUD insertion (including Povidone-Iodine or Chlorhexidine swab) using standard technique. IUD insertion: The IUD (Mirena® or ParaGard®) insertion procedure will occur in the usual manner for both arms. A bimanual exam will be performed, the speculum placed and the cervix visualized. The cervix will then by cleaned with iodine solution. If you are allergic to iodine, we will use chlorhexidine instead. A tenaculum will be placed on the cervix and a uterine sound will be used to measure cavity length. The Mirena® or ParaGard® IUD will be inserted with the specific introducer. Nitrous oxide: Given in a fixed dose ratio of 50% nitrous oxide/50% oxygen via nasal mask. | 0 | 40 | 0 | 40 |
Not provided
Not provided
| D014753 |
| Vinyl Compounds |
| D000475 | Alkenes |
| D006839 | Hydrocarbons, Acyclic |
| D006838 | Hydrocarbons |
| D009930 | Organic Chemicals |
| D011205 | Povidone |
| D011760 | Pyrrolidinones |
| D011759 | Pyrrolidines |
| D006573 | Heterocyclic Compounds, 1-Ring |
| D006571 | Heterocyclic Compounds |
| D010969 | Plastics |
| D011108 | Polymers |
| D046911 | Macromolecular Substances |
| D001697 | Biomedical and Dental Materials |
| D008420 | Manufactured Materials |
| D013676 | Technology, Industry, and Agriculture |
| D001645 | Biguanides |
| D006146 | Guanidines |
| D000578 | Amidines |
| D018011 | Chalcogens |
| D004602 | Elements |
| D005740 | Gases |
| D009589 | Nitrogen Oxides |
| D017672 | Nitrogen Compounds |
| D010087 | Oxides |
| D017601 | Oxygen Compounds |