Acute kidney injury(AKI) is one of the most common complications that occur up to 35% of critically ill patients. Septic AKI accounts for one third of them. Patients with septic AKI are widely treated with Continuous renal replacement therapy (CRRT). However, previous studies have hardly documented improvement of mortality in septic AKI patients. Otherwise, Fluid overload in septic shock patients who are undergoing CRRT is proven to be a significant predictor for mortality. Recent studies showed efficacy of bioelectrical impedance analysis and lung ultrasound in assessing fluid status of the patients. Thus, hypothesis of the study is that fluid assessment and control of fluid status using BIA and Lung Ultrasound could be related to the outcome of septic AKI patients who undergo CRRT. In this study, the investigators measure the fluid status of the patients by bioelectrical impedance analysis and lung ultrasound for experimental group, while for control group, fluid status would be determined clinically by the physician. Ultrafiltration rate of experimental group is adjusted to be equal to the value of overhydration measured by BIA.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| clinical-based ultrafiltration | Experimental |
| |
| BIA-based ultrafiltration | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Fluid management by the value of over hydration in Bioelectrical impedance | Procedure | In this study, investigator measure the fluid status of the patients by bioelectrical impedance analysis and lung ultrasound. The patients are assigned into two groups, BIA and Lung Ultrasound based versus clinical-based assessment group. Ultrafiltration of BIA and Lung Ultrasound based group is adjusted to be equal to the value of over hydration measured only by BIA, not by Lung Ultrasound, because Lung Ultrasound cannot determine exact amount of the patient's fluid excess. Total amount of ultrafiltration will be removed from the patient for three days evenly. On the other hand, Ultrafiltration amount will be decided by the physician in the clinical based group. Amount of fluid removal for a day will be adjusted not to exceed 2000ml, so that total fluid removed from the patient will not exceed 6000ml for three days. |
| Measure | Description | Time Frame |
|---|---|---|
| 28-day all cause mortality | 28th day from CRRT |
| Measure | Description | Time Frame |
|---|---|---|
| Dialysis free rate | 9 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Tae Hyun Yoo, MD | Contact | +82-2-2228-5345 | yoosy0316@yuhs.ac |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Severance Hospital | Recruiting | Seoul | 120-752 | South Korea |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Fluid management by clinical-based ultrafiltration | Procedure | In this study, investigator measure the fluid status of the patients by bioelectrical impedance analysis and lung ultrasound. The patients are assigned into two groups, BIA and Lung Ultrasound based versus clinical-based assessment group. Ultrafiltration of BIA and Lung Ultrasound based group is adjusted to be equal to the value of over hydration measured only by BIA, not by Lung Ultrasound, because Lung Ultrasound cannot determine exact amount of the patient's fluid excess. Total amount of ultrafiltration will be removed from the patient for three days evenly. On the other hand, Ultrafiltration amount will be decided by the physician in the clinical based group. Amount of fluid removal for a day will be adjusted not to exceed 2000ml, so that total fluid removed from the patient will not exceed 6000ml for three days. |
|