Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Baxter Healthcare Corporation | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The study investigates the performance of a new dialyzer (Theranova 400) containing a membrane with increased pore sizes. The performance will be determined by the removal of middle molecules (with different molecular size) from the blood compartment. Three different Theranova 400 prototypes (AA, BB and CC) operated in hemodialysis mode will be compared with a Cordiax FX-80 dialyzer, operated in hemodialysis mode. Safety events and albumin loss into the dialysate will be monitored
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| THERANOVA 400 dialyzer prototype AA | Experimental | THERANOVA 400 dialyzer prototype AA in hemodialysis treatment |
|
| THERANOVA 400 dialyzer prototype BB | Experimental | THERANOVA 400 dialyzer prototype BB in hemodialysis treatment |
|
| THERANOVA 400 dialyzer prototype CC | Experimental | THERANOVA 400 dialyzer prototype CC in hemodialysis treatment |
|
| FX CorDiax 80 dialyzer | Active Comparator | FX CorDiax 80 dialyzer in hemodialysis treatment |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| THERANOVA 400 dialyzer prototype AA | Device | Hemodialysis |
| |
| Measure | Description | Time Frame |
|---|---|---|
| Overall clearance of lambda immunoglobulin free light chains (molecular weight 45 kDa) | The primary efficacy endpoint is the overall clearance of lambda immunoglobulin free light chains during a mid-week hemodialysis session, assessed once with each experimental and active comparator product | One mid-week dialysis session |
| Measure | Description | Time Frame |
|---|---|---|
| Instantanous clearance of a set of molecules with molecular sizes between 60 Da and 45 kDa | One secondary efficacy endpoint is the instantaneous clearance of a set of molecules with molecular sizes from 60 Da to 45 kDa at 30 min after start of a mid-week hemodialysis session, assessed once with each experimental and active comparator product | At 30 min from start of a mid-week dialysis session |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ulrike Haug, Manager | Life Sciences & Operations, Gambro Dialysatoren GmbH ( a subsidiary of Baxter International Inc.) | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| LKH-Universität Klinikum Graz, Abteilung für Innere Medizin, Klinische Abteilung für Nephrologie und Dialyse | Graz | A-8036 | Austria |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 27587605 | Result | Kirsch AH, Lyko R, Nilsson LG, Beck W, Amdahl M, Lechner P, Schneider A, Wanner C, Rosenkranz AR, Krieter DH. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant. 2017 Jan 1;32(1):165-172. doi: 10.1093/ndt/gfw310. | |
| 28910799 | Result | Kirsch AH, Rosenkranz AR, Lyko R, Krieter DH. Effects of Hemodialysis Therapy Using Dialyzers with Medium Cut-Off Membranes on Middle Molecules. Contrib Nephrol. 2017;191:158-167. doi: 10.1159/000479264. Epub 2017 Sep 14. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| THERANOVA 400 dialyzer prototype BB |
| Device |
Hemodialysis |
|
| THERNOVA 400 dialyzer prototype CC | Device | Hemodialysis |
|
| FX CorDiax 80 dialyzer | Device | Hemodialysis |
|
| Instantanous clearance of a set of molecules with molecular sizes between 60 Da and 45 kDa | One secondary efficacy endpoint is the instantaneous clearance of a set of molecules with molecular sizes from 60 Da to 45 kDa at 120 min after start of a mid-week hemodialysis session, assessed once with each experimental and active comparator product | at 120 min from start of a mid-week dialysis session |
| Overall clearance of a set of molecules with molecular sizes between 60 Da and 40 kDa | One secondary efficacy endpoint is the overall clearance of a set of molecules from 60 Da to 40 kDa during one mid-week hemodialysis session, assessed once with each experimental and active comparator product | One mid-week dialysis session |
| Total mass removed of a set of molecules with molecular sizes between 60 Da and 45 kDa | One secondary efficacy endpoint is the total mass removed of a set of molecules from 60 Da to 45 kDa during one mid-week hemodialysis session, assessed once with each experimental and active comparator product | One mid-week dialysis session |
| Removal rate of a set of molecules with molecular sizes between 60 Da and 45 kDa | One secondary efficacy endpoint is the removal rate of a set of molecules from 60 Da to 45 kDa during one mid-week hemodialysis session, assessed once with each experimental and active comparator product | One mid-week dialysis session |
| Total mass removed of albumin | One secondary safety endpoint is the total removed mass of albumin during one mid-week hemodialysis session, assessed once with each experimental and active comparator product | One mid-week dialysis session |
| Post- to pre-dialysis changes in a set of hematology parameters (blood cell counts, hematocrit and hemoglobin) | One secondary safety endpoint is the change in hematology parameters during one mid-week hemodialysis session, assessed once with each experimental and active comparator product | One mid-week dialysis session |
| Types and frequency of adverse events and device deficiencies as a measure of safety and dialyzer tolerability | Any adverse events and device deficiencies will be recorded. | Continuously, from signature of informed consent form until 1 week after last hemodialysis session with an experimental or active comparator product, an expected average of 29 days |
| ID | Term |
|---|---|
| D007676 | Kidney Failure, Chronic |
| ID | Term |
|---|---|
| D051436 | Renal Insufficiency, Chronic |
| D051437 | Renal Insufficiency |
| D007674 | Kidney Diseases |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D002908 | Chronic Disease |
| D020969 | Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided