Not provided
Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| IRB201400800 | Other Identifier | UF IRB-01 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This is a single-center, non-randomized study.The study staff will use the InSpectraTM tissue oxygen saturation (StO2) monitor manufactured by Hutchinson Technology to measure baseline StO2 levels after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained, a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured. The investigators hypothesize that heart failure in children causes a baseline lower thenar tissue oxygen saturation (StO2), a faster rate of desaturation (Rdes) and a prolonged rate of reperfusion (Rres). The investigators also hypothesize that these changes will correlate with the severity of heart failure. The results of this study will provide groundwork for studies looking at correlation of therapy modification based on the combination thenar StO2 and clinical presentation.
Heart failure patients seen in the Pediatric Cardiology Congenital Heart Center will be enrolled into the study after obtaining informed consent on the day of their evaluation. The primary pediatric cardiologist following the patient will evaluate the need for regular investigations like blood work, electrocardiogram and echocardiogram. The study staff will use the InSpectraTM tissue oxygen saturation (StO2) monitor manufactured by Hutchinson Technology to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured. Similar measurements will be obtained from an otherwise healthy cohort of children who present to the Pediatric Cardiology Congenital Heart Center for evaluation of a heart murmur or chest pain. The patient's treating physician and care providers will be blinded to the study test results. All clinical care will be at the discretion of the patient's treating physicians. Only StO2 levels will be obtained using the non-invasive probe placed on the thenar eminence for the purpose of the study.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| InSpectraTM StO2 | InSpectraTM StO2 monitor manufactured by Hutchinson Technology Inc. to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero, whichever is earlier the cuff pressure will be released instantaneously and the rate of reperfusion (Rres; % × sec-1) will be measured. The measurement will be continued until the StO2 returns to the baseline value. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| InSpectraTM StO2 monitor | Device | InSpectraTM StO2 monitor manufactured by Hutchinson Technology Inc. to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence. After a stable reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded. After 3 minutes or once the StO2 level comes to zero, whichever is earlier the cuff pressure will be released instantaneously and the rate of reperfusion (Rres; % × sec-1) will be measured. The measurement will be continued until the StO2 returns to the baseline value. |
| Measure | Description | Time Frame |
|---|---|---|
| Baseline StO2 percentage | The study staff will use the InSpectraTM StO2 monitor manufactured by Hutchinson Technology to measure the baseline StO2 level after applying the noninvasive probe to the thenar eminence | Day 1 |
| Measure | Description | Time Frame |
|---|---|---|
| Occlusion- rate of desaturation (Rdes) of StO2 levels | After a stable baseline reading is obtained a blood pressure cuff will be inflated 40 mmHg above the obtained systolic pressure and the rate of desaturation (Rdes; % × sec-1) will be recorded for 3 min or until the StO2 level comes to zero (whichever is earlier). | Day 1 |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Stable Heart failure patients under 25 years of age with a diagnosis of cardiomyopathy, myocarditis or univentricular palliation for congenital heart disease in a primary pediatric cardiologist office
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Dipankar Gupta, MD | Contact | 352-273-7770 | dgupta@ufl.edu |
| Name | Affiliation | Role |
|---|---|---|
| Dipankar Gupta, MD | University of Florida | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Florida | Recruiting | Gainesville | Florida | 32610 | United States |
Individual participant will not be shared to avoid risk of loss of confidentiality.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Recovery- rate of reperfusion (Rres) of StO2 levels |
After 3 minutes from occlusion or once the StO2 level comes to zero (whichever is earlier), the cuff pressure will be released and the rate of reperfusion (Rres; % × sec-1) will be measured for approximately 3 min. |
| Day 1 |