The study seeks to evaluate a novel treatment approach for performing continuous real-time glucose sensing and insulin delivery at the same subcutaneous tissue site.
The treatment of type 1 diabetes usually comprises the measurement of glucose in blood obtained by finger pricking and the administration of insulin via subcutaneous bolus injection or continuous subcutaneous infusion.
This study seeks to test a new treatment approach where glucose sensing and insulin administration are combined and performed at a single subcutaneous tissue site (single-port treatment approach). A single-port device consisting of a continuous glucose sensor and an insulin infusion cannula is inserted into the subcutaneous tissue of 10 type-1 diabetes patients and used for insulin infusion and simultaneous glucose sensing over a 7-day period. The performance of the single-port device is assessed by comparing the obtained glucose readings with those of a blood glucose meter and an additionally worn control sensor.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| glucose sensing and insulin delivery | Experimental | Subcutaneous insulin delivery with an insulin pump plus glucose sensing with a continuous glucose sensor placed at the site of subcutaneous insulin delivery. In parallel, capillary glucose determinations using a conventional glucose meter as well as glucose sensing in subcutaneous, insulin-unexposed tissue using a continuous glucose sensor. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| insulin delivery | Drug | Subcutaneous insulin (100 U/ml, NovoRapid®; Novo Nordisk, Bagsvaerd, Denmark) delivery with an insulin pump (Vibe-TM; Animas Corp., West Chester, PA, USA) and an insulin infusion cannula (SOF-SET MICRO QR 6mm; Medtronic MiniMed, USA) placed at the same site as the continuous glucose sensor. |
| Measure | Description | Time Frame |
|---|---|---|
| Mean absolute relative difference between sensor readings and capillary glucose readings | Mean absolute relative differences calculated by determining the mean of the absolute value of the percentage difference between paired sensor and capillary glucose concentration | 7 days |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Thomeas R Pieber, MD | Medical University of Graz, Internal Medicine, Endocrinology and Metabolism | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Medical University of Graz | Graz | Styria | A-8036 | Austria |
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| glucose sensing | Device | Glucose sensing with a continuous glucose sensor (Dexcom G4 Platinum Sensor; Dexcom Inc., San Diego, USA) placed at the site of subcutaneous insulin delivery. |
|