Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Masimo Corporation | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Research has shown that pleth variability can be used to assess asthma severity in children with status asthmaticus. The investigators would like to use an FDA-cleared monitor (Masimo Radical 7) which measures Pleth Variability Index (PVI) to see if the degree of PVI can be used to help triage patients who present to the pediatric ED in status asthmaticus.
Patients with asthma have obstruction to exhalation resulting in hyperinflation of their lungs. This hyperinflation results in a phenomenon known as pulsus paradoxus in which the physiologic drop in blood pressure normally seen with inhalation is exaggerated. Studies have shown that patients with more severe asthma exacerbations (i.e. more hyperinflation) have a greater degree of pulsus paradoxus. Typically, pulsus paradoxus is measured using a sphygmomanometer, however, researchers have demonstrated that it can also accurately be measured using plethysmography, a term known as pleth variability index (PVI). Using this concept, Arnold et al (2008, 2010) showed that a greater degree of pulsus paradoxus correlates with asthma severity.
The investigators' study aims to simplify the association between PVI and asthma severity. The investigators hypothesize the following:
To do this the investigators will recruit children who present to the pediatric ED in status asthmaticus. They will be connected to a Masimo Radical 7 monitor upon admission to the ED and then again 4 hours later. In addition the investigators will calculate respiratory severity scores at those same time intervals. The investigators will then look at the disposition of the patient upon leaving the ED: discharge to home, admission to an inpatient floor or admission to the ICU.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Status Asthmaticus | Any patient presenting to the ED with status asthmaticus. |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Disposition from ED | Determine whether a patient was discharged from the ED, admitted to an inpatient floor or admitted to the ICU. | 4 hours |
| Measure | Description | Time Frame |
|---|---|---|
| Comparison to respiratory severity score | Is PVI as effective as RSS in determining asthma severity | 4 hours |
| Change in disposition within 24 hours | Determine if a patient who was discharged home from the ED required readmission to the ED within 1 week. Determine if a patient admitted to the floor or ICU required a change in level of care in the first 24 hours of admission. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
We will study patients who present to the pediatric ED at Cohen Children's Medical Center of NY with status asthmaticus.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Ariel Brandwein, MD | Northwell Health | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cohen Children's Medical Center of NY | New Hyde Park | New York | 11040 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 18410819 | Background | Arnold DH, Gebretsadik T, Minton PA, Higgins S, Hartert TV. Assessment of severity measures for acute asthma outcomes: a first step in developing an asthma clinical prediction rule. Am J Emerg Med. 2008 May;26(4):473-9. doi: 10.1016/j.ajem.2007.05.026. | |
| 20350320 | Background | Arnold DH, Jenkins CA, Hartert TV. Noninvasive assessment of asthma severity using pulse oximeter plethysmograph estimate of pulsus paradoxus physiology. BMC Pulm Med. 2010 Mar 29;10:17. doi: 10.1186/1471-2466-10-17. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D013224 | Status Asthmaticus |
| ID | Term |
|---|---|
| D001249 | Asthma |
| D001982 | Bronchial Diseases |
| D012140 | Respiratory Tract Diseases |
| D012130 | Respiratory Hypersensitivity |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| 1 week |
| 18522935 | Background | Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008 Aug;101(2):200-6. doi: 10.1093/bja/aen133. Epub 2008 Jun 2. |
| 14706958 | Background | Clark JA, Lieh-Lai M, Thomas R, Raghavan K, Sarnaik AP. Comparison of traditional and plethysmographic methods for measuring pulsus paradoxus. Arch Pediatr Adolesc Med. 2004 Jan;158(1):48-51. doi: 10.1001/archpedi.158.1.48. |
| 11180690 | Background | Frey B, Freezer N. Diagnostic value and pathophysiologic basis of pulsus paradoxus in infants and children with respiratory disease. Pediatr Pulmonol. 2001 Feb;31(2):138-43. doi: 10.1002/1099-0496(200102)31:23.0.co;2-r. |
| 16963672 | Background | Rayner J, Trespalacios F, Machan J, Potluri V, Brown G, Quattrucci LM, Jay GD. Continuous noninvasive measurement of pulsus paradoxus complements medical decision making in assessment of acute asthma severity. Chest. 2006 Sep;130(3):754-65. doi: 10.1378/chest.130.3.754. |
| D006969 |
| Hypersensitivity, Immediate |
| D006967 | Hypersensitivity |
| D007154 | Immune System Diseases |