Continuous lactate and glucose blood levels
MAQUET Group offers a new device that gives real time blood lactate and glucose levels. It is a new central veinous catheter with a microdialysis system. It is planted in the superior vena cava. It has not yet been used and validated with a clinical purpose, and particularly in cardiac surgery.
For now, reference method for determining blood lactate and glucose levels is co oxymetry.
This new simple device could provide great fluency for determining blood lactate and glucose levels. It could allow medical teams gain time for diagnosis and treatment of both hyperlactatemia and hyperglycemia.
The primary outcome of this study was to compare blood lactate and glucose absolute measures provided with the MAQUET new device (Maquet Critical Care AB, Solna, Sweden) and with co oxymetry.
The secondary outcome of this study was to compare variations of these absolutes measures.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| comparison of blood lactate and glucose levels | Device | comparison of blood lactate and glucose levels with the reference method (co oxymetry) and a new central veinous catheter microdialysis system provided by MAQUET. (Critical Care AB, Solna, Sweden.) |
|
| Measure | Description | Time Frame |
|---|---|---|
| comparison of absolute blood lactate and glucose levels with the reference method (co oxymetry) and a new method using a device providing real time measures of lactate and glycemia with a central veinous catheter microdialysis system. | Central veinous catheter, EIRUS (Maquet Critical Care AB, Solna, Sweden) | 1 day |
| Measure | Description | Time Frame |
|---|---|---|
| comparison of variations of blood lactate and glycemia levels with the reference method (co oxymetry) and a new method using a device providing real time measures of lactate and glycemia. (EIRUS) with a central veinous catheter microdialysis system. | Central veinous catheter, EIRUS (Maquet Critical Care AB, Solna, Sweden) | 1 day |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Consecutive patients of cardiac surgery. (planned or for emergencies)
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU de Caen | Caen | Basse Normandie | 14000 | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29028910 | Derived | Gouezel C, Lorne E, Bonnet V, Fradin S, Saplacan V, Gerard JL, Hanouz JL, Fellahi JL, Fischer MO; FHT (French Hemodynamic Team). Assessment of changes in lactate concentration with intravascular microdialysis during high-risk cardiac surgery using the trend interchangeability method. Br J Anaesth. 2017 Dec 1;119(6):1110-1117. doi: 10.1093/bja/aex338. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Blood samples for determination of lactate and glucose blood levels