In general bronchoscopy is a safe procedure with low rate of complications. Indeed, contraindications to flexible bronchoscopy are mostly relative rather than absolute. This is the case of preexisting decreased blood oxygen levels which may be present in patients requiring further bronchopulmonary investigation. To avoid the deleterious effects of oxygen drops oxygen supplementation is recommended.
The purpose of this study is to evaluate the efficiency and safety of oxygen supplementation obtained with the use of a high flow nasal cannula compared with a low flow nasal cannula during flexible bronchoscopy.
Consecutive patients referred by their treating physician for bronchoscopy will be offered to take part in the study. Those who wish to participate and give their consent will be randomly assigned into one of two treatment groups (supplemental oxygen given via low flow nasal cannula or via high flow nasal cannula).
Assignment to either treatment arm will not affect in any way the intended purpose of the bronchoscopy. All patients will be closely monitored during the procedure and 2 hours following its completion. Monitoring will be conducted, using strictly non-invasive measures.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Low flow nasal oxygen supplementation | Active Comparator | Low flow nasal oxygen supplementation as per routine standard of care(control arm) |
|
| High flow nasal oxygen supplementation | Experimental | High-flow nasal ventilation: This will be carried out using the Precision Flow device (Opti-Flow, Auckland, New Zealand). This device is intended to add warm moisture to breathing gases from an external source. Flow rate via the nasal cannula will be kept at 50 Liters/min and fractional inspired oxygen concentration will be set at 0.35 |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| High flow nasal oxygen supplementation | Device | High-flow nasal ventilation: This will be carried out using the Precision Flow device (Opti-Flow, Auckland, New Zealand). This device is intended to add warm moisture to breathing gases from an external source. Flow rate via the nasal cannula will be kept at 50 Liters/min and fractional inspired oxygen concentration will be set at 0.35. |
| Measure | Description | Time Frame |
|---|---|---|
| Oxygen desaturation index 4% (ODI4%) | duration of bronchoscopy with an expected average duration of 30 minutes | |
| oxygen cumulative time below 88%(OCT88%) | beginning to end of bronchoscopy procedure with an expected average duration of 30minutes |
| Measure | Description | Time Frame |
|---|---|---|
| number of bradycardic and tachycardic events | beginning to end of bronchoscopy with an expected averag duration of 30 minutes | |
| change in expired end tidal carbon dioxide before and after completion of bronchoscopy | beginning to end of bronchoscopy with an expected average duration of 30 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| patient comfort during the procedure | a numeric rating scale ranging from 1(excellent to 4(poor ) will be filled out by the patient after completion of the bronchoscopy | duration of bronchoscopy procedure with an expected average duration of 30 minutes |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Ayal Romem, MD | Contact | 97226555676 | pulmoromem@szmc.org.il |
| Name | Affiliation | Role |
|---|---|---|
| Ayal Romem, MD | Shaare Zedek Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Shaare Zedek Medical Center | Jerusalem | 3235 | Israel |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 4809326 | Background | Albertini R, Harrel JH, Moser KM. Letter: Hypoxemia during fiberoptic bronchoscopy. Chest. 1974 Jan;65(1):117-8. doi: 10.1378/chest.65.1.117. No abstract available. | |
| 6744959 | Background | Matsushima Y, Jones RL, King EG, Moysa G, Alton JD. Alterations in pulmonary mechanics and gas exchange during routine fiberoptic bronchoscopy. Chest. 1984 Aug;86(2):184-8. doi: 10.1378/chest.86.2.184. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000860 | Hypoxia |
| ID | Term |
|---|---|
| D012818 | Signs and Symptoms, Respiratory |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| low flow nasal oxygen supplementation | Device | Low-flow nasal ventilation: This will be carried out using a regular nasal cannula fed with oxygen at flow rates from 2 to 6 liters/minute. |
|
| oxygen desaturation index 4% | preprocedural to 2 hours post procedure with an expected total duration of 3 hours |
| cumulative oxygen time 88% | pre-procedural to 2 hours post precedure with an expected total duration of 3 hours |
| 23860341 | Background | Du Rand IA, Blaikley J, Booton R, Chaudhuri N, Gupta V, Khalid S, Mandal S, Martin J, Mills J, Navani N, Rahman NM, Wrightson JM, Munavvar M; British Thoracic Society Bronchoscopy Guideline Group. British Thoracic Society guideline for diagnostic flexible bronchoscopy in adults: accredited by NICE. Thorax. 2013 Aug;68 Suppl 1:i1-i44. doi: 10.1136/thoraxjnl-2013-203618. No abstract available. |
| Background | Roca O, Masclans JR, Laborda C, Sacanell J, Serra J. High-flow nasal cannula improves oxygenation in hypoxemic respiratory failure. Intensive Care Med 2007; 33:S86 |
| Background | Williams AB, Ritchie JE, Gerard C. Evaluation of a high-flow nasal oxygen delivery system: gas analysis and pharyngeal pressures. Intensive Care Med 2006; 32: S219 |
| Background | Lomas C, Roca O, Alvarez A, Masclans JR. Fibroscopy in patients with hypoxemic respiratory insufficiency: Utility of the high-flow nasal cannula. Respr Med (CME) 2009; 2: 121-124 |
| 22666567 | Background | Lucangelo U, Vassallo FG, Marras E, Ferluga M, Beziza E, Comuzzi L, Berlot G, Zin WA. High-flow nasal interface improves oxygenation in patients undergoing bronchoscopy. Crit Care Res Pract. 2012;2012:506382. doi: 10.1155/2012/506382. Epub 2012 May 20. |