The purpose of the study is to test the accuracy benefit of having two glucose sensors (over one sensor alone) when they are positioned: 2mm, 10mm, 20mm, or 30mm apart. It is not yet known how close two sensors can be and still work correctly.
An artificial pancreas system will likely require multiple glucose sensing elements to function safely. It is not yet known how close two glucose sensors can be placed and still work properly. Meaning, if one is reading inaccurately,and the other is positioned adjacent to it, will it read inaccurately also, defeating the purpose of having two sensors. Twenty adult subjects with Type 1 diabetes will wear four Medtronic REAL-Time glucose sensors during two separate 10-hour studies. The inter-sensor distances of each pair to be tested will be: 2, 10, 20, and 30mm apart. The sensors will be inserted the day prior to the study day to allow for signal stabilization and calibration. During the study day, arterialized venous blood will be drawn every 15 minutes to measure blood glucose. The sensor values and interstitial values will be recorded from each sensor receiver at each time point. Subjects will be fed two standardized meals and given pre-meal insulin based on their typical insulin to carbohydrate ratio.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Type 1 diabetic |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Difference between very large sensor accuracy errors (≥50% from reference glucose) with the simultaneous use of four sensors vs one sensor. | 9-hour collection period, X 2 |
| Measure | Description | Time Frame |
|---|---|---|
| Difference between mean absolute relative difference with the simultaneous use of four sensors vs one sensor. | 9-hour glucose level collection, X 2 |
Not provided
Inclusion Criteria:
Exclusion Criteria: Subjects presenting with any of the following will not be included in the study.
Not provided
Not provided
clinical practice Type 1 patients
Not provided
| Name | Affiliation | Role |
|---|---|---|
| W. Kenneth Ward, MD | Oregon Health and Science University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Oregon Health & Science University | Portland | Oregon | 97239 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 14709196 | Background | Ward WK, Casey HM, Quinn MJ, Federiuk IF, Wood MD. A fully implantable subcutaneous glucose sensor array: enhanced accuracy from multiple sensing units and a median-based algorithm. Diabetes Technol Ther. 2003;5(6):943-52. doi: 10.1089/152091503322640980. | |
| 8794921 | Background | Schmidtke DW, Pishko MV, Quinn CP, Heller A. Statistics for critical clinical decision making based on readings of pairs of implanted sensors. Anal Chem. 1996 Sep 1;68(17):2845-9. doi: 10.1021/ac9602027. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003922 | Diabetes Mellitus, Type 1 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| 20332355 | Result | Castle JR, Engle JM, El Youssef J, Massoud RG, Yuen KC, Kagan R, Ward WK. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care. 2010 Jun;33(6):1282-7. doi: 10.2337/dc09-2254. Epub 2010 Mar 23. |
| D004700 | Endocrine System Diseases |
| D001327 | Autoimmune Diseases |
| D007154 | Immune System Diseases |