Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| University of California, Los Angeles | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
When compared to existing analyses: manometry, Smart Pill and lactulose breath testing, external Acoustic Esophago-Gastro-Intestinal Surveillance (AEGIS) may identify unique audible patterns characteristic of features of gastroinestinal (GI) motility, gastric and small bowel contractions and emptying and small intestinal bacterial overgrowth (SIBO). This research study is designed to test the capabilities of AbStats/AEGIS to identify and associate symptoms and traditional diagnostics with sound readings and correlate this data with treatment outcomes and successes in standard of care.
In partnership with Dr. William Kaiser and the UCLA Wireless Health Institute, our research groups are developing and validating the diagnostic capabilities of device that conducts AEGIS. A belt (AbStats) fits externally around the abdomen and is embedded with acoustic sensors, similar to "electronic stethoscopes." The investigational software is designed to continuously, safely, and comfortably monitor acoustic signals emanating from the esophagus, stomach, and intestines, and stores the data in a HIPAA compliant hard drive. Through the study of associating these readings with current diagnostics and treatments we anticipate that the AEGIS device will eventually provide clinically interpretable information that is immediately actionable. In this study, the Abstats sensor will track signals in tandem with current techniques and standard of care treatments based on those diagnostics. AEGIS analysis could potentially refine, support, or even replace, existing costly and invasive techniques in the diagnosis of gastroparesis, intestinal psueodo-obstruction, colonic inertia, and disorders related to small intestinal bacterial overgrowth (SIBO).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Acoustic readings of the abdominal cavity and swallowing collected via the device during current standard of care small bowel manometry reading. | Acoustic readings would be recorded concurrent with standard of care diagnostics. There is no study follow up. Any patient follow up would be solely clinical standard of care, independent of study data or findings. | At the time that the standard of care diagnostic test is performed, an expected average of 6 hours |
| Acoustic readings of the abdominal cavity and swallowing collected via the device during current standard of care SmartPill transit recording. | Acoustic readings would be recorded concurrent with standard of care diagnostics. There is no study follow up. Any patient follow up would be solely clinical standard of care, independent of study data or findings. | At the time the standard of care diagnostic test is performed, up to 5 days |
| Acoustic readings of the abdominal cavity and swallowing collected via the device during standard of care breath testing. | Acoustic readings would be recorded concurrent with standard of care diagnostics. There is no study follow up. Any patient follow up would be solely clinical standard of care, independent of study data or findings. | At the time the standard of care diagnostic test is performed, up to 3 hours. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients referred to the Cedars-Sinai Motility Program who are already scheduled to undergo small bowel manometry, SmartPill, or Lactulose Hydrogen Breath Test.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mark Pimentel, MD | Cedars-Sinai Medical Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cedars-Sinai Medical Center | Los Angeles | California | 90048 | United States |
Not provided
Not provided
Not provided
Not provided