Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Gait and balance disorders are important public health problem necessitating studies to try to prevent falls. Many studies have dealt with spatiotemporal gait parameters or balance during quiet standing (posturography). Nevertheless, falls occurred predominantly during gait, and rarely during quiet standing. We have developed a tool to measure balance during gait : the braking of the center of mass (CM), a biomechanical parameter obtained from the vertical velocity of the CM recorded with a force plate.
In previous studies, we have shown that the braking of the CM was a physiological and a active mechanism, reflecting balance during gait. Unfortunately, the braking of the CM measured on a force plate provide an important intra-individual variability.
The 3D optoelectronic gait analysis system (VICON) also provide an estimation of the CM. The primary goal of this study is to compare intra-individual variability of the braking of the CM determined by a force plate or the 3D optoelectronic gait analysis system (VICON) in healthy subjects.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Gait analysis | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Gait analysis | Other | Subjects, barefoot and standing upright and motionless on a force plate, were instructed to walk for 10 m following a beep delivered by the experimenter. Two experimental conditions were tested: (i) the 'natural' gait condition where subjects walked normally and (ii) the 'fast' gait condition where subjects walked as fast as they could, taking large steps. Each subject performed 10 trials in each condition. |
| Measure | Description | Time Frame |
|---|---|---|
| Braking of the center of mass index during gait initiation | Braking of the center of mass (CM), a biomechanical parameter obtained from the vertical velocity of the CM, determined by a force plate or a 3D optoelectronic gait analysis system (VICON). | 1 day |
| Measure | Description | Time Frame |
|---|---|---|
| Braking of the center of mass index during locomotion | Braking of the center of mass (CM), a biomechanical parameter obtained from the vertical velocity of the CM, determined by a 3D optoelectronic gait analysis system (VICON). | 1 day |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Nathalie CHASTAN, MD | University Hospital, Rouen | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Rouen University Hospital | Rouen | France |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 34883958 | Result | Langeard A, Mathon C, Ould-Slimane M, Decker L, Bessot N, Gauthier A, Chastan N. Kinematics or Kinetics: Optimum Measurement of the Vertical Variations of the Center of Mass during Gait Initiation. Sensors (Basel). 2021 Nov 29;21(23):7954. doi: 10.3390/s21237954. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000077107 | Gait Analysis |
| ID | Term |
|---|---|
| D005684 | Gait |
| D010808 | Physical Examination |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| D000076604 |
| Physical Functional Performance |
| D010809 | Physical Fitness |
| D006262 | Health |
| D011154 | Population Characteristics |