The purpose of this study is to compare two methods that are currently used at the end of a CT guided lung biopsy to close the hole on the surface of the lung in order to minimize the chance of air leaking out of the hole. The two techniques consist of either injecting a very small amount of your the blood called a blood patch into the biopsy hole or injecting a gel-based FDA approved artificial plug called BioSentry that will eventually get absorbed into the body.
This study will determine the rate of all pneumothoraces and those pneumothoraces requiring treatment following percutaneous lung biopsy in patients who have received ABPI or BioSentry at the end of the biopsy procedure. The data collected will be used to determine if there is equal effectiveness in the reduction of pneumothorax rates from both interventions.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| autologous blood patch injection (ABPI) | Active Comparator |
| |
| BioSentry (formerly known as Bio-Seal) hydrogel Tract Plug | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| ABPI | Other | If the patient was assigned to the ABPI group, a blood patch will be administered using the clotted blood in the syringe obtained at the beginning of the procedure. The guiding needle will be retracted up to 1.5-2 cm from the pleural surface, and the blood will be injected steadily and gently as the needle is pulled back out of the pleura. Injection will stop when the operator feels the needle is in subcutaneous tissues. |
| Measure | Description | Time Frame |
|---|---|---|
| the Rate of Pneumothorax | within 2 hours following biopsy. Pneumothorax is observed on post procedure CT scan or on follow-up chest radiographs while the patient is in the recovery room, according to standard of care. | 2 hours post procedure |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Amgad Moussa, MD | Memorial Sloan Kettering Cancer Center | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Memorial Sloan Kettering Westchester | Harrison | New York | 10604 | United States | ||
| Memorial Sloan Kettering Cancer Center |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30480487 | Derived | Maybody M, Muallem N, Brown KT, Moskowitz CS, Hsu M, Zenobi CL, Jihad M, Getrajdman GI, Sofocleous CT, Erinjeri JP, Covey AM, Brody LA, Yarmohammadi H, Deipolyi AR, Bryce Y, Alago W, Siegelbaum RH, Durack JC, Gonzalez-Aguirre AJ, Ziv E, Boas FE, Solomon SB. Autologous Blood Patch Injection versus Hydrogel Plug in CT-guided Lung Biopsy: A Prospective Randomized Trial. Radiology. 2019 Feb;290(2):547-554. doi: 10.1148/radiol.2018181140. Epub 2018 Nov 27. |
| Label | URL |
|---|---|
| Memorial Sloan Kettering Cancer Center | View source |
Not provided
Not provided
Not provided
Not provided
| ID | Title | Description |
|---|---|---|
| FG000 | Autologous Blood Patch Injection (ABPI) | ABPI: If the patient was assigned to the ABPI group, a blood patch will be administered using the clotted blood in the syringe obtained at the beginning of the procedure. The guiding needle will be retracted up to 1.5-2 cm from the pleural surface, and the blood will be injected steadily and gently as the needle is pulled back out of the pleura. Injection will stop when the operator feels the needle is in subcutaneous tissues. |
| Title | Milestones | Reasons Not Completed | |||||
|---|---|---|---|---|---|---|---|
| Overall Study |
|
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jan 18, 2022 |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| BioSentry (formerly known as Bio-Seal) hydrogel Tract Plug | Device | If the patient is assigned to BioSentry group, using the manufacturer's deployment device the introducer needle is positioned so that the tip is at least 1.5 cm deep to the visceral pleura. The coaxial introducer needle hub will be prehydrated with a drop of saline, the BioSentry plug housing will be mated and locked to the hub and the plug will be deployed. |
|
| New York |
| New York |
| 10065 |
| United States |
| FG001 | BioSentry (Formerly Known as Bio-Seal) Hydrogel Tract Plug | BioSentry (formerly known as Bio-Seal) hydrogel Tract Plug: If the patient is assigned to BioSentry group, using the manufacturer's deployment device the introducer needle is positioned so that the tip is at least 1.5 cm deep to the visceral pleura. The coaxial introducer needle hub will be prehydrated with a drop of saline, the BioSentry plug housing will be mated and locked to the hub and the plug will be deployed. |
| COMPLETED |
|
| NOT COMPLETED |
|
|
Not provided
| ID | Title | Description |
|---|---|---|
| BG000 | Autologous Blood Patch Injection (ABPI) | ABPI: If the patient was assigned to the ABPI group, a blood patch will be administered using the clotted blood in the syringe obtained at the beginning of the procedure. The guiding needle will be retracted up to 1.5-2 cm from the pleural surface, and the blood will be injected steadily and gently as the needle is pulled back out of the pleura. Injection will stop when the operator feels the needle is in subcutaneous tissues. |
| BG001 | BioSentry (Formerly Known as Bio-Seal) Hydrogel Tract Plug | BioSentry (formerly known as Bio-Seal) hydrogel Tract Plug: If the patient is assigned to BioSentry group, using the manufacturer's deployment device the introducer needle is positioned so that the tip is at least 1.5 cm deep to the visceral pleura. The coaxial introducer needle hub will be prehydrated with a drop of saline, the BioSentry plug housing will be mated and locked to the hub and the plug will be deployed. |
| BG002 | Total | Total of all reporting groups |
| Units | Counts |
|---|---|
| Participants |
|
| Title | Description | Population Description | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Denominator Units Selected | Denominators | Classes | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Age, Continuous | Mean | Full Range | years |
| |||||||||||||||
| Sex: Female, Male | Count of Participants | Participants |
| ||||||||||||||||
| Ethnicity (NIH/OMB) | Count of Participants | Participants |
| ||||||||||||||||
| Race (NIH/OMB) | Count of Participants | Participants |
| ||||||||||||||||
| Region of Enrollment | Count of Participants | Participants |
|
| Type | Title | Description | Population Description | Reporting Status | Anticipated Posting Date | Parameter Type | Dispersion Type | Unit of Measure | Calculate Percentage | Time Frame | Units Analyzed | Denominator Units Selected | Arm/Group Information | Denominators | Classes | Analyses | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Primary | the Rate of Pneumothorax | within 2 hours following biopsy. Pneumothorax is observed on post procedure CT scan or on follow-up chest radiographs while the patient is in the recovery room, according to standard of care. | Posted | Count of Participants | Participants | 2 hours post procedure |
|
|
|
2 weeks post procedure
Not provided
Not provided
| ID | Title | Description | Deaths (Affected) | Deaths (At Risk) | Serious Events (Affected) | Serious Events (At Risk) | Other Events (Affected) | Other Events (At Risk) |
|---|---|---|---|---|---|---|---|---|
| EG000 | Autologous Blood Patch Injection (ABPI) | ABPI: If the patient was assigned to the ABPI group, a blood patch will be administered using the clotted blood in the syringe obtained at the beginning of the procedure. The guiding needle will be retracted up to 1.5-2 cm from the pleural surface, and the blood will be injected steadily and gently as the needle is pulled back out of the pleura. Injection will stop when the operator feels the needle is in subcutaneous tissues. | 0 | 226 | 0 | 226 | 0 | 226 |
| EG001 | BioSentry (Formerly Known as Bio-Seal) Hydrogel Tract Plug | BioSentry (formerly known as Bio-Seal) hydrogel Tract Plug: If the patient is assigned to BioSentry group, using the manufacturer's deployment device the introducer needle is positioned so that the tip is at least 1.5 cm deep to the visceral pleura. The coaxial introducer needle hub will be prehydrated with a drop of saline, the BioSentry plug housing will be mated and locked to the hub and the plug will be deployed. | 0 | 228 | 0 | 228 | 0 | 228 |
Not provided
Not provided
Not provided
Not provided
Not provided
| Title | Organization | Phone | Extension | |
|---|---|---|---|---|
| Dr. Amgad Moussa MD | Memorial Sloan Kettering Cancer Center | 212-639-3690 | moussaa@mskcc.org |
| Jan 3, 2024 |
| Prot_SAP_000.pdf |
| Male |
|
| Not Hispanic or Latino |
|
| Unknown or Not Reported |
|
| Asian |
|
| Native Hawaiian or Other Pacific Islander |
|
| Black or African American |
|
| White |
|
| More than one race |
|
| Unknown or Not Reported |
|