Supraglottic airway devices (SADs) are well established in anesthetic practice. Among these devices ,classic laryngeal airway has been typically widely used. The self-pressurised air-Q (air-Q) is newly developed supraglottic airway devices. It is a new single-use device that may optimise the airway sealing while reducing the potential for postoperative complications such as sore throat. The overall structure of the air-Q SP is identical to the original air-Q, except with regard to the inflatable cuff. The aim of this randomized trial was to compare the clinical performance of the classic LMA and the air-Q SP.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| 1)C-LMA group | Experimental |
| |
| 2)Air-Q group | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Insertion of C-LMA | Device | After induction of general anesthesia, C-LMA or Air-Q was inserted according to randomly allocated group. |
|
| Measure | Description | Time Frame |
|---|---|---|
| airway leak pressure measured after device insertion | Airway leak pressure was determined by adjusting the expiratory valve of the breathing circle to 40 cmH2O (fixed fresh gas flow 3 L/min) and recording the pressure when equilibrium was reached. | within 5min to 10 min insertion of each device |
| Measure | Description | Time Frame |
|---|---|---|
| Insertion time | Insertion time was defined as the time from the attending anesthesiologist picking up the LMA until the confirmation on capnography. | During and 1 min after insertion of each device |
| Measure | Description | Time Frame |
|---|---|---|
| Ease of insertion | Ease of insertion was graded from 1 to 4. | During and 1 min after insertion of each device |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Human research Protection Center, Gangnam Severance Hospital, | Seoul | 120-752 | South Korea |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 29524199 | Derived | Ha SH, Kim MS, Suh J, Lee JS. Self-pressurized air-Q(R) intubating laryngeal airway versus the LMA(R) Classic: a randomized clinical trial. Can J Anaesth. 2018 May;65(5):543-550. doi: 10.1007/s12630-018-1082-6. Epub 2018 Feb 6. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Insertion of air-Q according | Device | After induction of general anesthesia, C-LMA or Air-Q was inserted according to randomly allocated group. |
|