Interscalene plexus block is a widely used technique to provide anesthesia and analgesia for surgery at the upper extremity (shoulder and upper arm); it is standard-of-care in many institutions worldwide. Local anesthetic is being injected around the nerves supplying the arm (Plexus brachialis) at a specific location in the arm (between the scalenus muscles, thus called "interscalene plexus block"). The optimal volume of injection with regard to efficacy, safety and avoidance of untoward effects has been subject to intense debate for a long time. In spite of evidence that small volumes (between 5 and 7 mls) are effective for adequate postoperative analgesia, larger volumes up to 40 mls are still frequently used in many practices. However, with the use of such large doses, adverse events are known to occur with increased frequency, including paralysis of the diaphragm or spread of local anesthetic to the spinal cord.
This study is intended to help evaluate the effects of small or larger injection of local anesthetic around the brachial plexus, and to correlate the distribution with clinical efficacy, block duration, and possible side effects. It is a randomized, controlled, observer-blinded trial; patients undergoing shoulder or upper arm surgery will be randomly allocated to receive either 5mls or 20mls of local anesthetic for their interscalene plexus block. Magnetic resonance imaging will be performed immediately afterwards, followed by a series of neurological exams during the hospital stay. Test of lung function (spirometry) and ultrasound of the diaphragm will be used to evaluate effects of the block on respiratory mechanics.
Background: Interscalene plexus blockade (ISB) is frequently used during surgery of the upper limb. The use of ultrasound has significantly reduced time of onset and total volume of local anesthetics in comparison to nerve localization by stimulators. (1-4) The introduction of this technique has been correlated with decreased volumes of effective local anesthetics from 40 milliliters and more down to 10 milliliters and less.(3-4) As the injection site of ISB is located in close proximity to the anatomical structures of the spinal cord, spread of local anesthetics could potentially cause adverse events, including contralateral blockade and total spinal anesthesia. Case reports on these complications have been published previously. (5-11)In a recently published study we showed that the phenomenon of epidural spread can be reproduced in cadavers and seems to be positively correlated to injection-volumes exceeding 10 milliliters.(12) Moreover, we observed a trend towards cranial spread of the contrast agent in all investigated specimens along the course of the nerval roots towards the spinal cord. In another cadaveric study by Orebauch et al., cranial epidural spread was also detectable following injection of dye into the nerval roots of the brachial plexus.(13) Magnetic resonance imaging has not yet been used for visualization of the spread of local anaesthetics in ISB.
Given that ultrasound provides excellent visualization of target-structures in regional anesthesia and therefore enables physicians to place injection needles with enormous accuracy, the question arises whether there is a critical volume for local anesthetics increasing complications such as epidural spread and in consequence contralateral blockade.
The aim of this study is to confirm the findings of our cadaveric study in vivo and to show that the frequency of epidural spread correlates with injection of increased volumes of local anesthetics.
Primary endpoint: Spread of local anesthetics to the epidural space
Secondary endpoints:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Interscalene Nerve Block - 5ml | Experimental | ultrasound guided interscalene plexus block (UISB) Ropivacaine 0.75%, 20ml Gadopentetate-Dimeglumine 0.05 mmol Shoulder Surgery |
|
| Interscalene Nerve Block - 20ml | Active Comparator | ultrasound guided interscalene plexus block (UISB) Ropivacaine 0.75%, 5ml Gadopentetate-Dimeglumine 0.0125 mmol Shoulder Surgery |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Interscalene Nerve Block | Procedure | ultrasound guided interscalene plexus block (UISB) immediately before magnetic resonance imaging of the neck. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Spread of local anesthetics to the epidural space | Spread of local anesthetics to the epidural space, as seen in the magnetic resonance imaging | 10 minutes |
| Measure | Description | Time Frame |
|---|---|---|
| Contralateral epidural spread | as seen on MRI | 10 min |
| Spread of local anesthetics to the phrenic nerve | as seen on MRI | 10 minutes |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Peter Gerner, MD | Department of Anesthesiology, Perioperative Medicine and Intensive Care, Paracelsus Medical University, Salzburg, Austria | Study Chair |
| Gerhard Fritsch, MD | Department of Anesthesiology, Perioperative Medicine and Intensive Care, Paracelsus Medical University, Salzburg, Austria | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Paracelsus Medical University, Department of Anesthesiology | Salzburg | State of Salzburg | 5020 | Austria |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 19916253 | Background | Fredrickson MJ, Ball CM, Dalgleish AJ. A prospective randomized comparison of ultrasound guidance versus neurostimulation for interscalene catheter placement. Reg Anesth Pain Med. 2009 Nov-Dec;34(6):590-4. doi: 10.1097/aap.0b013e3181ada622. | |
| 19372356 | Background | Fredrickson MJ, Ball CM, Dalgleish AJ, Stewart AW, Short TG. A prospective randomized comparison of ultrasound and neurostimulation as needle end points for interscalene catheter placement. Anesth Analg. 2009 May;108(5):1695-700. doi: 10.1213/ane.0b013e31819c29b8. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000077212 | Ropivacaine |
| D019786 | Gadolinium DTPA |
| ID | Term |
|---|---|
| D000813 | Anilides |
| D000577 | Amides |
| D009930 | Organic Chemicals |
| D000814 | Aniline Compounds |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Ropivacaine 0.75%, 20ml | Drug | 20 ml of ropivacaine 0.75% |
|
|
| Gadopentetate-Dimeglumine 0.0125 mmol | Drug | 0.0125 mmol of gadopentetate-dimeglumine |
|
|
| Gadopentetate-Dimeglumine 0.05 mmol | Drug | 0.05 mmol of gadopentetate-dimeglumine |
|
|
| Ropivacaine 0.75%, 5ml | Drug | 5 ml of ropivacaine 0.75% |
|
|
| Shoulder Surgery | Procedure | As per individual requirement (patient-dependent) |
|
| Bed side spirometry and ultrasound investigation of the diaphragm in the PACU | 24 hours |
| Oxygen saturation in the PACU | 2-6 hours |
| Self-reported block duration | 24 hours |
| Self reported pain scores for the first 24 postoperative hours | 24 hrs |
| Time to first analgesic consumption on demand | 24 hours |
| Total analgesic consumption (ropivacaine PCA). | 24 hours |
| 21821517 | Background | Gautier P, Vandepitte C, Ramquet C, DeCoopman M, Xu D, Hadzic A. The minimum effective anesthetic volume of 0.75% ropivacaine in ultrasound-guided interscalene brachial plexus block. Anesth Analg. 2011 Oct;113(4):951-5. doi: 10.1213/ANE.0b013e31822b876f. Epub 2011 Aug 4. |
| 23353796 | Background | Vandepitte C, Gautier P, Xu D, Salviz EA, Hadzic A. Effective volume of ropivacaine 0.75% through a catheter required for interscalene brachial plexus blockade. Anesthesiology. 2013 Apr;118(4):863-7. doi: 10.1097/ALN.0b013e3182850dc7. |
| 1252000 | Background | Cobcroft MD. Letter: Bilateral spread of analgesia with interscalene brachial plexus block. Anaesth Intensive Care. 1976 Feb;4(1):73. No abstract available. |
| 20652841 | Background | Dooley J, Fingerman M, Melton S, Klein SM. Contralateral local anesthetic spread from an outpatient interscalene catheter. Can J Anaesth. 2010 Oct;57(10):936-9. doi: 10.1007/s12630-010-9360-y. Epub 2010 Jul 23. |
| 19604186 | Background | Fredrickson MJ, Kilfoyle DH. Neurological complication analysis of 1000 ultrasound guided peripheral nerve blocks for elective orthopaedic surgery: a prospective study. Anaesthesia. 2009 Aug;64(8):836-44. doi: 10.1111/j.1365-2044.2009.05938.x. |
| 1632560 | Background | Gologorsky E, Leanza RF. Contralateral anesthesia following interscalene block. Anesth Analg. 1992 Aug;75(2):311-2. doi: 10.1213/00000539-199208000-00046. No abstract available. |
| 16704597 | Background | Gomez RS, Mendes TC. Epidural anaesthesia as a complication of attempted brachial plexus blockade using the posterior approach. Anaesthesia. 2006 Jun;61(6):591-2. doi: 10.1111/j.1365-2044.2006.04647.x. |
| 5124750 | Background | Kumar A, Battit GE, Froese AB, Long MC. Bilateral cervical and thoracic epidural blockade complicating interscalene brachial plexus block: report of two cases. Anesthesiology. 1971 Dec;35(6):650-2. doi: 10.1097/00000542-197112000-00022. No abstract available. |
| 6838002 | Background | Lombard TP, Couper JL. Bilateral spread of analgesia following interscalene brachial plexus block. Anesthesiology. 1983 May;58(5):472-3. doi: 10.1097/00000542-198305000-00016. No abstract available. |
| 23222362 | Background | Fritsch G, Hudelmaier M, Danninger T, Brummett C, Bock M, McCoy M. Bilateral loss of neural function after interscalene plexus blockade may be caused by epidural spread of local anesthetics: a cadaveric study. Reg Anesth Pain Med. 2013 Jan-Feb;38(1):64-8. doi: 10.1097/AAP.0b013e318277a870. |
| 20814286 | Background | Orebaugh SL, McFadden K, Skorupan H, Bigeleisen PE. Subepineurial injection in ultrasound-guided interscalene needle tip placement. Reg Anesth Pain Med. 2010 Sep-Oct;35(5):450-4. doi: 10.1097/AAP.0b013e3181e859f0. |
| 26865133 | Derived | Stundner O, Meissnitzer M, Brummett CM, Moser S, Forstner R, Kokofer A, Danninger T, Gerner P, Kirchmair L, Fritsch G. Comparison of tissue distribution, phrenic nerve involvement, and epidural spread in standard- vs low-volume ultrasound-guided interscalene plexus block using contrast magnetic resonance imaging: a randomized, controlled trial. Br J Anaesth. 2016 Mar;116(3):405-12. doi: 10.1093/bja/aev550. |
| D000588 |
| Amines |
| D004369 | Pentetic Acid |
| D011073 | Polyamines |
| D000085 | Acetates |
| D000144 | Acids, Acyclic |
| D002264 | Carboxylic Acids |
| D056831 | Coordination Complexes |