Obesity has become a significant health problem in Canada. It is known to be a risk factor for many diseases, including Gastro-Esophageal Reflux Disease (GERD). When medical efforts to lose weight fail, patients often consider bariatric surgical procedures as the next step. The two most common bariatric procedures performed are Roux-en-Y Gastric Bypass (LRYGB) and Laparoscopic Sleeve Gastrectomy (LSG). The gold standard for diagnosing GERD is Esophageal pH monitoring, as it is the most objective method to document the reflux, assess the severity and monitor the response to treatment of the disease. In the last few years LSG has gained in popularity due to its simplicity and short operative time. Currently the comparison between bariatric surgery and GERD symptoms is very one sided. There are significant numbers of studies with conclusive results that state that LRYGB has a positive effect on GERD symptoms, however there is little evidence that states the same about LSG. This means that the relationship between LSG and GERD is inconclusive. An objective evaluation of GERD using 24 hour pH monitoring and validated CRFs at different follow up time points will contribute greatly to our understanding of what this relationship might be.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| GERD Symptoms | Active Comparator |
| |
| No GERD Symptoms | Active Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 24 pH monitoring | Other | The study is performed with the patient fasting for a minimum of 6 hours. A single channel or dual channel (15 cm spacing) pH probe is inserted trans nasally. The pH sensor, or distal pH sensor in the case of 2 channel testing, is positioned 5 cm above the proximal margin of the LES, as determined by esophageal manometric testing. pH-Z ambulatory monitor (Given Imaging Digitrapper) is used for data acquisition and the data analyzed with pH Analysis Program (Given Imaging AccuView). The number of reflux events, defined as a drop in esophageal pH readings below 4.0, is recorded and the percentage of time with esophageal acid exposure is analyzed using defined protocols and accepted normal values. |
| Measure | Description | Time Frame |
|---|---|---|
| Observe acid exposure to the distal esophagus | This will be measured using the esophageal 24 hours monitoring before surgery and at the 6 month follow up. The patients will be randomized to two different types of surgery and the results compared. | 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| Compare GERD symptoms in patients. | This will be measured using esophageal manometry prior to surgery and at the six month follow up visit. We are looking for time in minutes with a pH of below 4 and a Demeeser score of below 14.7 | 1 year |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mehran Anvari, MB BS, PhD | Centre for Minimal Access Surgery, McMaster University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| St. Joseph's Healthcare | Hamilton | Ontario | L8N 4A6 | Canada |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Esophageal Manometry: | Other | A high resolution esophageal manometry catheter is used for testing and inserted Trans nasally. The patient is given 10 liquid swallows (5mL of water), at intervals of approximately 30 seconds. The catheter (Sierra Scientific/Given Imaging) has 36 sensors, each one averaging pressures from 12 circumferential positions. This gives a total of 432 data points. The sensors are placed 1 cm apart, spanning a length of 35 cm. The catheter simultaneously records pressure readings from the esophagus, sphincter regions (UES and LES), pharynx and stomach without the need for a station pull-through technique. Results are reported according to defined protocols and accepted normal values. |
|
| ID | Term |
|---|---|
| D005764 | Gastroesophageal Reflux |
| ID | Term |
|---|---|
| D015154 | Esophageal Motility Disorders |
| D003680 | Deglutition Disorders |
| D004935 | Esophageal Diseases |
| D005767 | Gastrointestinal Diseases |
| D004066 | Digestive System Diseases |
Not provided
Not provided