"Nanotechnologies applied to General Surgery and Emergency Surgery: The Buckypaper as a new fixing method for prosthetic materials in the treatment of abdominal wall hernias, diaphragmatic hernias, diaphragmatic rupture, incisional hernia and abdominal wall disaster in laparotomy procedure and laparoscopic procedures". Experimentation on breed pig Lantrace ANIMAL MODEL.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| laparotomy with PPL mesh implantation | Active Comparator | control group: laparotomy with PPL mesh implantation (traditional method) |
|
| laparotomy with PPL fixation by BP | Experimental | laparotomic surgery with PPL mesh fixation by BP (new fixing method) |
|
| laparoscopy with PPL mesh implantation | Active Comparator | control group: laparoscopy with PPL mesh implantation (traditional method) |
|
| laparoscopy with PPL fixation by BP | Experimental | laparoscopic surgery with PPL mesh fixation by BP (new fixing method) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| PPL fixation by BP | Device | A surgical scar was performed on the abdominal linea alba and carried out deeply into a pocket between large abdominal muscle and abdominal fascia. A pocket was created between the two layers. 5cm PLL prosthesis was implanted and fixed by BP patch. The scar was sutured with absorbable stitches on subcutaneous incision and not absorbable stitches on the cutaneous layer. |
| Measure | Description | Time Frame |
|---|---|---|
| Time of durability without side effects of surgical device | We are testing the time (months/year) of durability without side effects of a new fixing method for prosthetic materials for abdominal wall hernias and wall defects repairing on pig model | up to 36 months |
| Measure | Description | Time Frame |
|---|---|---|
| time required to position the device during surgery | time required to position the device during surgery (time is related with probability of side effect during surgery) | up to 36 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Massimo Chiaretti, MD, PhD, MSc | University of Roma La Sapienza | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Animal House Agostino Gemelli University of Rome. | Rome | RM | 00168 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23635074 | Background | Martinelli A, Carru GA, D'Ilario L, Caprioli F, Chiaretti M, Crisante F, Francolini I, Piozzi A. Wet adhesion of buckypaper produced from oxidized multiwalled carbon nanotubes on soft animal tissue. ACS Appl Mater Interfaces. 2013 May 22;5(10):4340-9. doi: 10.1021/am400543s. Epub 2013 May 1. | |
| 20148633 | Background |
Not provided
Not provided
Not provided
| G Ceccarelli | UNKNOWN |
| AI Chiaretti | UNKNOWN |
| P Consentino | UNKNOWN |
| E Valente | UNKNOWN |
Not provided
Not provided
Not provided
Not provided
|
|
| PPL mesh | Device | A surgical scar was performed on the abdominal linea alba and carried out deeply into a pocket between large abdominal muscle and abdominal fascia. A pocket was created between the two layers. 5cm PLL prosthesis was implanted and fixed by absorbable stichtes. The scar was sutured with absorbable stitches on subcutaneous incision and not absorbable suture on the cutaneous layer. |
|
|
| Bellucci S, Chiaretti M, Onorato P, Rossella F, Grandi MS, Galinetto P, Sacco I, Micciulla F. Micro-Raman study of the role of sterilization on carbon nanotubes for biomedical applications. Nanomedicine (Lond). 2010 Feb;5(2):209-15. doi: 10.2217/nnm.09.100. |
| 19572819 | Background | Bellucci S, Chiaretti M, Cucina A, Carru GA, Chiaretti AI. Multiwalled carbon nanotube buckypaper: toxicology and biological effects in vitro and in vivo. Nanomedicine (Lond). 2009 Jul;4(5):531-40. doi: 10.2217/nnm.09.36. |
| 19063954 | Background | Di Sotto A, Chiaretti M, Carru GA, Bellucci S, Mazzanti G. Multi-walled carbon nanotubes: Lack of mutagenic activity in the bacterial reverse mutation assay. Toxicol Lett. 2009 Feb 10;184(3):192-7. doi: 10.1016/j.toxlet.2008.11.007. Epub 2008 Nov 21. |
| ID | Term |
|---|---|
| D006547 | Hernia |
| D000069290 | Incisional Hernia |
| ID | Term |
|---|---|
| D020763 | Pathological Conditions, Anatomical |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D011183 | Postoperative Complications |