Rubidium is a newly approved nuclear medicine imaging drug or 'tracer' used to look at blood flow in the heart. This tracer is given using a special pump called an 'elution system' which is considered investigational. This means the device is not yet approved by Health Canada for general use, but it has been approved for use in this study. It has been used routinely in this hospital since 2010.
The purpose of this study is to confirm proper operation of the pump. It may also help identify areas for future improvement. The study data may be used for safety reporting to the Ministry of Health or to Health Canada. The study will enroll 2,400 patients in 6 hospitals across Canada. The University of Ottawa Heart Institute (UOHI) will enroll up to 1,200 patients.
Primary Objectives: To evaluate performance of the rubidium elution systems (RBES) manufactured by Jubilant DraxImage (JDI); specifically using the constant-activity-rate intravenous infusion of rubidium-82 from the Ruby-Fillâ„¢ generator for diagnostic imaging of myocardial perfusion with PET. The V3 elution system is more highly automated, therefore requiring fewer manual performance checks.
Hypotheses:
Performance: system operation using constant-activity infusion is adequate to achieve:
Daily Quality Assurance: testing procedures are adequate to document:
Monthly Quality Assurance: testing procedures are adequate to document:
Installation of the Ruby-Fill generator and Ruby-Set tubing (V2 and V3)
Trouble-shooting and repair of system errors (e.g. high-pressure) (V2 and V3) 2.3 Tertiary Objective: To evaluate patient demographics or health status effects on system performance
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Coronary artery disease | All patients present to participating nuclear imaging facilities for diagnosis of CAD and/or risk stratification with Rubidium PET. Subjects will be enrolled according to the clinical indications listed in the approved Ruby-Fill product monograph. |
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| System Performance: | System operation using constant-activity infusion is adequate to achieve:
| 1 year |
| Daily Quality Assurance: | System testing procedures are adequate to document:
| 1 year |
| Monthly Quality Assurance | System testing procedures are adequate to document:
| 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| User documentation | To evaluate the user documentation and training reliability for:
| 1 year |
Not provided
Inclusion Criteria:
All patients presenting to participating nuclear imaging facilities with Rb-82 PET for diagnosis and/or risk stratification for CAD (as listed in the approved Ruby-Fill product monograph), who are at least 18 years of age and have given informed consent or those who have consented to and are currently participating in an Ottawa Health Science Network Research Ethics Board (OHSN-REB) approved protocol utilizing Rb-82 PET will be eligible.
Exclusion Criteria:
Not provided
Not provided
Not provided
All patients present to participating nuclear imaging facilities for diagnosis of CAD and/or risk stratification with Rubidium PET. Subjects will be enrolled according to the clinical indications listed in the approved Ruby-Fill product monograph.
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Rob S Beanlands, MD | Ottawa Heart Institute Research Corporation | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hamilton Healath Sciences Centre | Hamilton | Ontario | Canada | |||
| London Health Sciences Centre |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 17228112 | Background | Klein R, Adler A, Beanlands RS, Dekemp RA. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007 Feb 7;52(3):659-73. doi: 10.1088/0031-9155/52/3/009. Epub 2007 Jan 11. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D017202 | Myocardial Ischemia |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| London |
| Ontario |
| Canada |
| University of Ottawa Heart Institute | Ottawa | Ontario | K1Y 4W7 | Canada |
| University Health Network | Toronto | Ontario | Canada |
| D001161 |
| Arteriosclerosis |
| D001157 | Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |