Laparoscopic Cholecystectomy applied to Artificial pneumoperitoneum and the extent of Surgical stimulation cause the wave of hemodynamics increase vigorously, which make it difficult to judge the depth of anesthesia according to traditional hemodynamics index such as heart rate and blood pressure.In case of this, the investigators design this research to study the Closed-Loop Target Controlled Infusion to anaesthesia of individualization guided by a Narcotrend index monitor in Laparoscopic Cholecystectomy.
Anesthetics alter electrocortical activity in a dose-dependent manner,and it is suggested that electroencephalographic(EEG)activity can provide a reliable basis for a surrogate measurement of hypnosis.An EEG monitor,the Narcotrend Index(NI),has proven useful to titrate hypnotic drugs.Because it is a single composite measure monitored continuously,it has been used in controlled studies to automatically guide propofol administration.Conversely,automated delivery systems for opioids have seldom been described using EEG activity There are no specific measures to quantify analgesia directly.Nevertheless,in the interaction between opioid-hypnotic synergy and loss of consciousness,when the dose of analgesic administered is sufficient to inhibit autonomic response to noxious stimuli,then the required hypnotic concentration is only that needed to achieve loss of consciousness.Moreover,a noxious stimulus such as laryngoscopy or periosteal pressure to the tibia may cause electrocortical activation with an increase in Narcotrend index,which indirectly reflects the analgesic state or the level of antinociception.Finally,an excitatory EEG arousal reaction resulting from nociceptive stimulation can provide a rational basis for analgesia administration.It can then be hypothesized that Narcotrend index could also be the controlled variable for opioid administration.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Closed-loop TCI | Experimental | the controller in the current study measures and calculates the error(NI error),which is the difference between the set point(NI=36)and the measured NI.If the NI error is different from 0,the controller determines a new propoflo and/or remifentanil concentration. |
|
| Opened-loop TCI | Placebo Comparator | the investigator modified the effect-site target concentrations of both drugs without minimum or maximum concentration limits to maintain NI at approximately 36 within a range of 26 to 46 to the extent possible. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Closed-loop TCI | Device | the controller in the current study measures and calculates the error(NI error),which is the difference between the set point(NI=36)and the measured NI.If the NI error is different from 0,the controller determines a new propoflo and/or remifentanil concentration. |
| Measure | Description | Time Frame |
|---|---|---|
| Narcotrend index | the controller in the current study measures and calculates the error(NI error),which is the difference between the set point(NI=36)and the measured NI.If the NI error is different from 0,the controller determines a new propoflo and/or remifentanil concentration.The error size determines which drug will be modified:if the NI error is small,only the remifentanil is changed;if the NI error is higher,the two drug concentrations are changed. | 5minutes |
| Measure | Description | Time Frame |
|---|---|---|
| induction duration | duration of induction defined as the time elapsed from the start of propofol administration to the moment when the NI value decreased to <46 | within 10 minutes from the start of of propofol administration |
| Measure | Description | Time Frame |
|---|---|---|
| 26<NI<46 | percentage of time in which the NI index between 26 and 46 during the maintenance. | within two hours from the beginning to the end of the infusion of propofol |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| bo xu | Contact | 88653387 | 020 | xubo333@hotmail.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Guangzhou Military Region General Hospital, Department of Anesthesiology | Recruiting | Guangzhou | Guangdong | 510010 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 21233500 | Background | Liu N, Chazot T, Hamada S, Landais A, Boichut N, Dussaussoy C, Trillat B, Beydon L, Samain E, Sessler DI, Fischler M. Closed-loop coadministration of propofol and remifentanil guided by bispectral index: a randomized multicenter study. Anesth Analg. 2011 Mar;112(3):546-57. doi: 10.1213/ANE.0b013e318205680b. Epub 2011 Jan 13. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D041761 | Cholecystolithiasis |
| ID | Term |
|---|---|
| D002769 | Cholelithiasis |
| D001660 | Biliary Tract Diseases |
| D004066 | Digestive System Diseases |
| D005705 | Gallbladder Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Opened-loop TCI | Device | the investigator modified the effect-site target concentrations of both drugs without minimum or maximum concentration limits to maintain NI at approximately 36 within a range of 26 to 46 to the extent possible. |
|