Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Boston Scientific Corporation | INDUSTRY |
| Biosensors Europe SA | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The purpose of this study is to perform a randomised comparison between the SYNERGY and the Biomatrix NeoFlex stents in treatment of unselected patients with ischemic heart disease.
SORT-OUT VIII is a randomised, multicenter, all-comer, two-arm, non-inferiority trial comparing the everolimus-eluting SYNERGY stent versus the Biomatrix NeoFlex stent in treatment of atherosclerotic coronary artery lesions.
Primary Endpoint:
Device-related Target Lesion Failure (TLF) hierarchically as cardiac death, non-index procedure related acute myocardial infarction (AMI) not clearly related to another lesion than the target lesion, or target lesion revascularisation (TLR) (new revascularization of target lesion) (significant stenosis in the stent ± 5 mm distal/proximal) by percutaneous coronary intervention (PCI) or coronary artery bypass operation (CABG) within 12 months.
Secondary Endpoint:
Device-related target lesion failure hierarchically as cardiac death, non-index procedure related acute myocardial infarction, not clearly related to another lesion than the target lesion, or new target lesion revascularization by percutaneous coronary intervention or coronary bypass operation at 2-5 years.
Patient-related combined endpoint hierarchically as all-cause death, non-index procedure related acute myocardial infarction or all new revascularizations by percutaneous coronary intervention or coronary bypass operation at 12, 24, 36, 48 and 60 months.
Individual above mentioned stent- or patient-related endpoints at 12, 24, 36, 48 and 60 months
MACE (combined endpoint as cardiac death, acute myocardial infarction or new revascularization of the study vessel)
Stent thrombosis defined according to the Academic Research Consortium (ARC) criteria within 24 hours (acute), between 1 and 30 days (subacute), between 30 days and 12 months (late), and after 12, 24, 36, 48 and 60 months (very late).
Device success rate defined as the frequency of a successful implantation with residual stenosis < 20% of the study stent in all the stenoses scheduled to be treated.
Procedural success rate defined as the frequency of successful implantation with residual stenosis <20% of the study stent in all the stenoses scheduled to be treated and without serious complications (cardiac death, non-index procedure related acute myocardial infarction related to target vessel or new revascularization of target lesion by percutaneous coronary intervention or coronary bypass operation).
Inclusion criteria:
All patients aged ≥18 years who are eligible for treatment with one or several drug-eluting coronary stents at one of the three heart centers in Odense, Skejby and Aalborg can be included in the study.
Exclusion criteria Age < 18 years The patient does not wish to participate The patient is not able to consent to randomization (eg intubated patients) The patient do not live in Western Denmark The patient do not speak Danish The patient is already included in this study The patient is participating in other stent studies Life expectancy <1 year Allergic to Aspirin, clopidogrel, prasugrel or ticagrelor Allergic to everolimus or biolimus Only implanted bare metal stents (BMS) Only performed plain old balloon angioplasty (POBA)
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| SYNERGY | Active Comparator | Coronary implantatation of the SYNERGY everolimus-eluting stent |
|
| Biomatrix Neoflex | Active Comparator | Coronary implantation of the biolimus-eluting Biomatrix NeoFlex stent |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Biomatrix NeoFlex coronary stent | Device | Percutaneous coronary intervention involving use of stent |
|
| Measure | Description | Time Frame |
|---|---|---|
| Device-related target lesion failure | Hierarchically as cardiac death, non-index procedure related acute myocardial infarction not clearly related to another lesion than the target lesion, or target lesion revascularisation (new revascularisation of target lesion revascularisation (significant stenosis in the stent =/+ 5 mm distal/proximal) by percutaneous coronary intervention or coronary artery bypass operation | 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Device-related target lesion failure | Hierarchically as cardiac death, non-index procedure related acute myocardial infarction not clearly related to another lesion than the target lesion, or target lesion revascularisation (new revascularisation of target lesion revascularisation by percutaneous coronary intervention or coronary artery bypass operation | 2, 3, 4 and 5 years |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Michael Maeng, MD | Aarhus University Hospital, Skejby, Aarhus N | Principal Investigator |
| Evald H Christiansen, MD | Aarhus University Hospital | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Aarhus University Hospital | Skejby | Aarhus N | 8200 | Denmark | ||
| Aarhus University Hospital Aalborg |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30947936 | Derived | Maeng M, Christiansen EH, Raungaard B, Kahlert J, Terkelsen CJ, Kristensen SD, Carstensen S, Aaroe J, Jensen SE, Villadsen AB, Lassen JF, Thim T, Eftekhari A, Veien KT, Hansen KN, Junker A, Botker HE, Jensen LO; SORT OUT VIII Investigators. Everolimus-Eluting Versus Biolimus-Eluting Stents With Biodegradable Polymers in Unselected Patients Undergoing Percutaneous Coronary Intervention: A Randomized Noninferiority Trial With 1-Year Follow-Up (SORT OUT VIII Trial). JACC Cardiovasc Interv. 2019 Apr 8;12(7):624-633. doi: 10.1016/j.jcin.2018.12.036. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003324 | Coronary Artery Disease |
| D017202 | Myocardial Ischemia |
| D000787 | Angina Pectoris |
| ID | Term |
|---|---|
| D003327 | Coronary Disease |
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D001161 | Arteriosclerosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| SYNERGY stent | Device | Percutaneous coronary intervention involving use of stent |
|
|
| Patient-related combined endpoint | Hierarchically as all-cause death, non-index procedure related acute myocardial infarction, or all new revascularisation by percutaneous coronary intervention or coronary artery bypass operation | 1, 2, 3, 4 and 5 year |
| Individual above mentioned stent- or patient-related endpoints | 1, 2, 3, 4 and 5 years |
| MACE | Combined endpoint as cardiac death, acute myocardial infarction or new revascularisation of the study vessel | 1, 2, 3, 4 and 5 years |
| Stent thrombosis | Stent thrombosis according to the Academic Research Consortium definitions | Within 24 hours, between 1 and 30 days, between 30 days and 12 months and after 1, 2, 3, 4 and 5 years |
| Device success rate | The frequency of a successful implantation with residual stenosis <20% of the study stent in all stenoses scheduled to be treated | intraoperative |
| Aalborg |
| 9000 |
| Denmark |
| Odense University Hospital | Odense | 5000 | Denmark |
| D001157 |
| Arterial Occlusive Diseases |
| D014652 | Vascular Diseases |
| D002637 | Chest Pain |
| D010146 | Pain |
| D009461 | Neurologic Manifestations |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |