To compare the efficiency of surgical procedures using 2 phaco tip designs in torsional phacoemulsification using the bevel-down technique.
In this prospective, comparative, masked study, patients will be randomly assigned to have torsional coaxial microincision cataract surgery using either the mini-flared 45-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. Clinical measurements will include preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC) and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements will include phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE) and balanced salt solution volume (BSS).
The study was performed according to established ethical standards for clinical research Institutional Review Board (IRB) of the University of Sao Paulo in Brazil, conducted between November 2010 and February of 2011. All surgeries will be performed at the University of Sao Paulo. Physicians conducting postoperative evaluation will not have access to patients' medical records. Exclusion criteria will be previous ocular surgery, central endothelial cell count less than 2000 cells/mm2, glaucoma or intraocular pressure greater than 21 mmHg, amblyopia, retinal abnormalities, steroid or immunosuppressive treatment and connective tissue diseases. Enrolled patients who have complicated cataract surgery (eg, posterior capsule rupture, vitreous loss, or an intraocular lens not placed in the capsular bag) will be subsequently excluded.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Reversed tip | Active Comparator | Reversed Kelman tip |
|
| Mini-flared | Experimental | Mini-flared Kelman tip |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Mini-flared | Device | Mini-flared Kelman tip |
| |
| Reversed tip |
| Measure | Description | Time Frame |
|---|---|---|
| Early Treatment Diabetic Retinopathy (ETDRS) visual acuities | 90 days |
| Measure | Description | Time Frame |
|---|---|---|
| Phaco time used | 1 day, 90 days |
| Measure | Description | Time Frame |
|---|---|---|
| Cumulative dissipated energy (CDE) required | 1 day, 90 days |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Patrick F Tzelikis, MD, PhD | Hospital Oftalmologico de Brasilia | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital Oftalmologico de BrasÃlia | BrasÃlia | Federal District | 70000 | Brazil |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 15030845 | Result | Vargas LG, Holzer MP, Solomon KD, Sandoval HP, Auffarth GU, Apple DJ. Endothelial cell integrity after phacoemulsification with 2 different handpieces. J Cataract Refract Surg. 2004 Feb;30(2):478-82. doi: 10.1016/S0886-3350(03)00620-5. | |
| 16863978 | Result | Payne M, Georgescu D, Waite AN, Olson RJ. Phacoemulsification tip vacuum pressure: Comparison of 4 devices. J Cataract Refract Surg. 2006 Aug;32(8):1374-7. doi: 10.1016/j.jcrs.2006.02.066. |
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
Reversed Kelman tip |
|
| 12231329 | Result | Frohn A, Dick HB, Fritzen CP. Corneal impact of ultrasound and bevel position in phacoemulsification. J Cataract Refract Surg. 2002 Sep;28(9):1667-70. doi: 10.1016/s0886-3350(02)01306-8. |